Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Rev. argent. radiol ; 81(1): 3-11, mar. 2017. ilus, tab
Article in Spanish | LILACS | ID: biblio-843249

ABSTRACT

Objetivo: Determinar el rendimiento diagnóstico de la histerosalpingografía por resonancia magnética (HSG-RM), utilizando la laparoscopia como método de referencia. Materiales y métodos: Se incluyeron 22 pacientes. A todas se les realizó una HSG-RM con un resonador 1.5 Tesla y luego una laparoscopia con cromotubación. Dos radiólogos examinaron las RM, determinando la permeabilidad tubaria por consenso. Se realizaron análisis descriptivos y de rendimiento diagnóstico. Resultados: La HSG-RM tuvo una tasa de éxito del 91%. La duración del estudio fue 49ą15 minutos, el volumen inyectado 26 ą 16 cm³ y la escala de dolor 30ą 19 de 100. La sensibilidad y especificidad de la HSG-RM fueron del 100% para la prueba de Cotte global y a la izquierda, y del 25% y 93,3% para la prueba de Cotte a la derecha, respectivamente. Hubo 2 complicaciones menores y ninguna importante. Discusión: Nuestros resultados iniciales demostraron una alta sensibilidad y especificidad. Si bien otros estudios analizaron la capacidad de la HSG-RM para evaluar la permeabilidad tubaria con buenos resultados, el uso de un patrón de referencia defectuoso dejaba margen para una duda razonable, impidiendo una recomendación basada en pruebas sólidas. Sin embargo, al cotejar nuestros resultados con los publicados, observamos un alto grado de concordancia en tanto el derrame positivo se diagnostica correctamente con una especificidad de 100% o con un porcentaje cercano a esta cifra. Conclusión: La HSG-MR es una alternativa factible y segura de la HSG convencional o virtual, la histerosonografía y la cromotubación.


Objective: To determine the diagnostic performance of magnetic resonance hysterosalpingography (MRHSG) using laparoscopic chromotubation as a method of reference. Materials and methods: Twenty-two patients were included. The MRHSG was performed in a 1.5 Tesla MR scanner. Afterwards, patients underwent laparoscopic chromotubation. MR images were examined by two trained radiologists, and tubal patency was determined by consensus. A descriptive analysis was carried out, as well as an analysis of the diagnostic performance. Results: MRHSG had a 91% success rate. Exam duration of the examination was 49ą15min, with an injected volume 26ą 16cc, and pain scale 30ą 19 out of 100. Sensitivity and specificity of MRHSG was 100% for global and left Cotte, and 25% and 93.3% for right Cotte, respectively. Only 2 minor and no major complications were observed. Discussion: The initial results of MRHSG have shown high sensitivity and specificity. Even though other studies have analysed the potential of MRHSG with good results, the use of a flawed reference standard left a margin for a reasonable doubt as regards its true potential, thus preventing a solid evidence based recommendation. Nevertheless, if our results are compared to those published, a high level of agreement is observed in that positive spillage is correctly diagnosed with specificities near or at 100%. Conclusion: MRHSG is a feasible and safe alternative to conventional or virtual HSG, ultrasound-hysterography and chromotubation.


Subject(s)
Humans , Female , Hysterosalpingography/methods , Magnetic Resonance Spectroscopy , Fallopian Tube Patency Tests , Laparoscopy
SELECTION OF CITATIONS
SEARCH DETAIL