Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Klin Lab Diagn ; 61(3): 151-4, 167-8, 2016 Mar.
Article in Russian | MEDLINE | ID: mdl-27506106

ABSTRACT

The article presents diagnostic of night paroxysmal hemoglobinuria. The night paroxysmal hemoglobinuria is an orphan disease characterized by absence of GPI-anchor on blood cells as a result of mutation of PIG-A gene on the short arm of X-chromosome. The particular proteins bounded with GPI-anchor implement function of defense from activation of components of complement and development of membrane-attacking complex. The erythrocytes exposed to destruction in bloodstream are among the most impacted. Therefore, one of the main signs of night paroxysmal hemoglobinuria is complement-depending intravascular hemolysis which indicators for a long time played a key role in diagnostic of night paroxysmal hemoglobinuria. The actual technique of diagnostic of night paroxysmal hemoglobinuria is flow cytometry. The analysis of night paroxysmal hemoglobinuria clone is recommended to patients with hemolysis of unclear genesis, thrombosis of cerebral and abdominal veins, thrombocytopenia and macrocytosis and also patients with AA, myelodysplastic syndrome, myelofibrosis. The international protocol recommended by the International Society of Clinical Cytometry (2010) is implemented to diagnose night paroxysmal hemoglobinuria. The original technique of evaluation of reticulocytes was developed with purpose to detect night paroxysmal hemoglobinuria clone. The high correlation was substantiated between size of night paroxysmal hemoglobinuria clone measured among reticulocytes according to proposed mode and night paroxysmal hemoglobinuria clone measured among granulocytes and monocytes detected according international standardized approach.


Subject(s)
Complement Membrane Attack Complex/metabolism , Erythrocyte Membrane/metabolism , Flow Cytometry/methods , Hemoglobinuria, Paroxysmal/blood , Hemoglobinuria, Paroxysmal/diagnosis , Membrane Proteins/blood , Chromosomes, Human, X , Complement Activation/genetics , Complement Membrane Attack Complex/genetics , Diagnosis, Differential , Erythrocyte Membrane/genetics , Female , GPI-Linked Proteins/blood , GPI-Linked Proteins/genetics , Hemoglobinuria, Paroxysmal/genetics , Humans , Male , Membrane Proteins/genetics , Mutation , Reticulocyte Count
2.
Klin Lab Diagn ; (7): 54-8, 2013 Jul.
Article in Russian | MEDLINE | ID: mdl-24341193

ABSTRACT

The flow cytometry becomes a more and more largely applied technique. However, the sufficient novelty of technique has no worked-out standards of diagnostic of many diseases. The lacking of external control of quality promotes development of large variety of approaches to diagnostic of diseases and impossibility to compare the study results from different laboratories. The paroxysmal night hemoglobinuria is an acquired clonal disease characterized by proliferation of stem cells with partial or total loss of expression of glykosylphosphosphatidyl inositol anchor needed to conjugate a number of surface proteins. The flow cytometry is a basic technique of detection and monitoring of clone of paroxysmal night hemoglobinuria. The article presents the results of paroxysmal night hemoglobinuria testing of 8 patients in 6 independent laboratories using flow cytometry by standard protocol recommended by the International society of clinical cytometrists (ICCS).


Subject(s)
Flow Cytometry/standards , Hemoglobinuria, Paroxysmal/diagnosis , Adult , Female , Flow Cytometry/methods , Hemoglobinuria, Paroxysmal/blood , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...