Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters











Publication year range
1.
Acta Paediatr ; 82(2): 155-61, 1993 Feb.
Article in English | MEDLINE | ID: mdl-8477160

ABSTRACT

Magnetic resonance imaging was performed in 23 patients with short stature (7 had multiple pituitary hormone defect, 11 had isolated growth hormone deficiency and 5 had normal variant short stature) to investigate if there is a relation between magnetic resonance findings and results of endocrine tests. Magnetic resonance imaging of patients with multiple pituitary hormone deficiency or with serious isolated growth hormone deficiency (growth hormone < 3 micrograms/l) revealed an interrupted pituitary stalk and ectopic neurohypophysis or a mass. In patients with less serious isolated growth hormone deficiency (growth hormone > 3 micrograms/l) or with normal variant short stature, the technique revealed a normal or hypoplastic hypophysis. Magnetic resonance appears to be a useful second-level diagnostic tool in defining the type of alteration in growth defects of endocrine origin.


Subject(s)
Growth Disorders/diagnosis , Hypothalamic Diseases/diagnosis , Pituitary Diseases/diagnosis , Adolescent , Body Height , Child , Female , Growth Disorders/physiopathology , Growth Hormone/deficiency , Humans , Hypothalamic Diseases/physiopathology , Hypothalamus/pathology , Magnetic Resonance Imaging , Male , Pituitary Diseases/physiopathology , Pituitary Gland/pathology , Pituitary Hormones/deficiency
2.
Minerva Med ; 81(1-2): 1-4, 1990.
Article in Italian | MEDLINE | ID: mdl-2314610

ABSTRACT

In 16 patients with high cortisol plasma levels MRI and CT investigation of adrenal gland region was performed; 13 also had the pituitary region examined. CT and MRI results in Cushing's Syndrome due to adrenal glands etiology (8 cases) are overlapping. The morphological criteria utilized consist in the radiological finding of bilateral adrenal hyperplasia or adrenal mass (adenoma, carcinoma). The great amount of retroperitoneal fat increases the normal contrast with both techniques. In the pituitary Cushing's Syndrome MRI was more sensible than CT as far as it concerns ACTH producing pituitary lesion assessment; this technique may show 5 mm diameter adenomas for their high signal intensity.


Subject(s)
Cushing Syndrome/diagnosis , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Adenoma/complications , Adenoma/diagnosis , Adenoma/diagnostic imaging , Adolescent , Adrenal Gland Neoplasms/complications , Adrenal Gland Neoplasms/diagnosis , Adrenal Gland Neoplasms/diagnostic imaging , Adrenocortical Hyperfunction/complications , Adrenocortical Hyperfunction/diagnosis , Adrenocortical Hyperfunction/diagnostic imaging , Adult , Aged , Carcinoma/complications , Carcinoma/diagnosis , Carcinoma/diagnostic imaging , Cushing Syndrome/diagnostic imaging , Cushing Syndrome/etiology , Female , Humans , Male , Middle Aged
3.
J Clin Endocrinol Metab ; 69(4): 725-8, 1989 Oct.
Article in English | MEDLINE | ID: mdl-2570790

ABSTRACT

Cabergoline (CAB) is a new oral dopaminergic compound showing a very long-lasting PRL-lowering activity and reported to be well tolerated. The efficacy and tolerability of chronic treatment with CAB in 30 female hyperprolactinemic patients, aged 18-52 yr (6 microadenomas, 3 macroadenomas, and 21 functional hyperprolactinemias), were studied. In a group of 10 patients who received CAB (0.8 mg once weekly or 0.4 mg twice weekly) for 8 weeks PRL levels normalized while on treatment and remained normal (8 patients) or greatly reduced (1 patient) for 1-2 months after discontinuation of the drug. Twenty-six patients underwent chronic treatment (6-12 months) with an initial dose of 0.5 mg once weekly, subsequently increased to 1-2 mg in 10 patients and decreased in the other 2. Due to severe side-effects CAB was discontinued in 3 patients, in 1, 8, and 12 weeks. A significant reduction of PRL levels was already observed after the first week of treatment (mean +/- SEM basal values, 90.1 +/- 13.3 vs. 29.5 +/- 6.3 micrograms/L; P less than 0.001). Twenty-two patients had normal PRL levels in 1-36 weeks (mean, 6 weeks) with 0.5-2 mg CAB. Twenty-two patients resumed regular menses; 2 patients became pregnant after 3-11 months of treatment. Thirteen patients complained of side-effects (nausea, hypotension, headache, gastric pain, dizziness, and weakness) that disappeared with time in 10 of them. The comparison with a previous bromocriptine treatment regimen in 20 patients had shown that the number of patients requiring discontinuation of the latter drug was significantly higher (7 vs. 3 patients; P less than 0.001). However, 2 patients who needed to discontinue CAB were able to tolerate bromocriptine therapy. A computed tomographic scan performed after 12 months of therapy in 7 patients showed a significant reduction (50%) of the adenoma in 5. In conclusion, our results show that CAB is a well tolerated new dopamine agonist with long-lasting activity that represents an advance in chronic medical treatment of hyperprolactinemic conditions.


Subject(s)
Dopamine Agents/therapeutic use , Ergolines/therapeutic use , Hyperprolactinemia/drug therapy , Adenoma/drug therapy , Adenoma/metabolism , Adenoma/surgery , Adult , Amenorrhea/chemically induced , Bromocriptine/adverse effects , Bromocriptine/therapeutic use , Cabergoline , Ergolines/adverse effects , Female , Humans , Hyperprolactinemia/blood , Hyperprolactinemia/etiology , Pituitary Neoplasms/drug therapy , Pituitary Neoplasms/metabolism , Pituitary Neoplasms/surgery , Prolactin/blood , Prolactin/metabolism
4.
Ann Ital Med Int ; 4(2): 122-4, 1989.
Article in English | MEDLINE | ID: mdl-2562003

ABSTRACT

Two cases of pituitary-dependent Cushing's syndrome are described in which the computed tomography (CT) examination was negative; as the hormone dynamic investigations were directed towards the presence of corticotropin (ACTH) secreting pituitary formations, magnetic resonance imaging (MRI) of the pituitary was performed, which evidenced the presence of such lesions; subsequent neurosurgery confirmed in both cases the location indicated by MRI. In conclusion, the higher sensitivity of MRI compared to CT in the diagnosis of ACTH secreting pituitary adenomas can be noted.


Subject(s)
Adenoma/diagnosis , Adrenocorticotropic Hormone/metabolism , Magnetic Resonance Imaging , Pituitary Neoplasms/diagnosis , Tomography, X-Ray Computed , Adenoma/diagnostic imaging , Adenoma/metabolism , Adenoma, Basophil/diagnosis , Adenoma, Basophil/diagnostic imaging , Adenoma, Basophil/metabolism , Adolescent , Cushing Syndrome/diagnosis , Cushing Syndrome/diagnostic imaging , Evaluation Studies as Topic , Female , Humans , Male , Middle Aged , Pituitary Neoplasms/diagnostic imaging , Pituitary Neoplasms/metabolism
5.
Radiol Med ; 77(1-2): 51-64, 1989.
Article in Italian | MEDLINE | ID: mdl-2928565

ABSTRACT

Normal CT and MR anatomy was studied in two series (53 and 25 cases respectively) of young volunteers of both sexes, asymptomatic and certainly without lesions of the pituitary gland. 115 other pathological cases (73 hyperprolactinemias, 8 acromegalies, 15 Cushing syndromes, 2 hyperthyroidisms, 17 nonsecreting adenomas) were examined using both CT and MRI. Both an accurate review of the relative literature and the results of our own series prove that MR is superior to CT in diagnosing pituitary microadenomas (3.2% not diagnosed with MRI and 25.8% not diagnosed with CT), in the follow-up of prolactinomas subjected to medical therapy and in the study of extrasellar involvement of pituitary adenomas, particularly with regard to the demonstration of compression of the optic chiasma.


Subject(s)
Magnetic Resonance Imaging , Pituitary Gland/diagnostic imaging , Tomography, X-Ray Computed , Adenoma/diagnosis , Diagnosis, Differential , Empty Sella Syndrome/diagnosis , Humans , Magnetic Resonance Imaging/methods , Pituitary Gland/anatomy & histology , Pituitary Neoplasms/diagnosis , Prolactinoma/diagnosis , Reference Values , Tomography, X-Ray Computed/methods
6.
Radiol Med ; 76(6): 530-3, 1988 Dec.
Article in Italian | MEDLINE | ID: mdl-3212234

ABSTRACT

Between February 1979 and December 1986, 618 lung biopsies were performed on 496 patients (122 with double puncture, using Tru-cut and 19-20 G needles). Overall diagnostic accuracy was 84.5%; the 77 patients examined in the past 18 months only underwent thin needle (19-20 G) biopsies--which were carried out by an experienced radiologist--and more sophisticated cyto-histological techniques were employed. Such a procedure gave better results (sensitivity 94.1%, accuracy 94.8%) than did the use of larger caliber needles in the past years; moreover, no complications occurred in these patients. In conclusion, 19-20 G needles are to be preferred to bigger ones, provided that the operator be experienced and cyto-histology be correctly performed.


Subject(s)
Biopsy, Needle , Lung Neoplasms/pathology , Lung/pathology , Adolescent , Adult , Aged , Biopsy, Needle/instrumentation , Biopsy, Needle/methods , Child , Evaluation Studies as Topic , Female , Humans , Male , Middle Aged
7.
Radiol Med ; 76(5): 443-7, 1988 Nov.
Article in Italian | MEDLINE | ID: mdl-3060902

ABSTRACT

The results are reported of 283 percutaneous biopsies performed on solid thoracic and abdominal masses. Indications to biopsy are examined at first, which are relatively limited in number if compared to other authors' opinion on the subject--i.e., when the tumor cannot be characterized with any other methodology, or in case of neoplasms whose histological type is to be known in order to plan therapy. The techniques employed are then evaluated, with a special emphasis on the needle caliber and the guidance method (US, radioscopy and CT). Correct samplings have been obtained in more than 90% of cases. Minor complications were observed in less than 10% of cases, while major complications were totally absent. In conclusion, percutaneous biopsy proves useful in those cases where exam indication is respected and an accurate selection is previously performed.


Subject(s)
Abdominal Neoplasms/diagnosis , Biopsy, Needle/methods , Thoracic Neoplasms/diagnosis , Abdomen/pathology , Abdominal Neoplasms/pathology , Biopsy, Needle/instrumentation , Fluoroscopy , Humans , Needles , Radiography, Abdominal , Radiography, Thoracic , Television , Thoracic Neoplasms/pathology , Thorax/pathology , Tomography, X-Ray Computed , Ultrasonography
8.
Radiol Med ; 75(5): 505-9, 1988 May.
Article in Italian | MEDLINE | ID: mdl-3287503

ABSTRACT

The authors discuss the possible role of Magnetic Resonance Imaging (MRI) in the follow-up of renal transplants. Its diagnostic accuracy is compared with Ultrasounds (US), which is considered the method of choice in postoperative monitoring of renal transplants. Thirty-two patients (transplant life ranging from 5 days to 37 months) were examined in the same day with both MRI and US. Sonographic evaluation is based on a group of signs related to renal alterations and unanimously ascertained; the identification of MR patterns of normally functioning kidney or renal rejection might give way to more extensive clinical applications of the method, with the advantages of multiplanarity and no X-ray use. MR diagnostic accuracy in the diagnosis of normally functioning transplant or renal rejection was 82.7% (vs. US: 68.9%); even though specificity was the same (84.6%). MRI had higher sensibility than US (82.25% vs. 656.25%). MRI is more sensitive in demonstrating renal pathology in transplanted kidneys, and its diagnostic accuracy is superior. Still, US must be considered the methodology of choice in instrumental research when there is a clinical suspicion of renal rejection, due to its sufficient diagnostic accuracy, to its being easy to perform in continuous follow-up, to its low cost and to the short execution time. MRI is nevertheless suggested in the follow-up of renal transplants both in questionable cases and when biopsy cannot be performed.


Subject(s)
Kidney Transplantation , Magnetic Resonance Imaging , Adolescent , Adult , Aged , Female , Follow-Up Studies , Graft Rejection , Humans , Kidney/pathology , Kidney/physiology , Male , Middle Aged , Time Factors , Ultrasonography
9.
Radiol Med ; 75(5): 515-20, 1988 May.
Article in Italian | MEDLINE | ID: mdl-3375495

ABSTRACT

Twenty-five patients affected by adrenal glands pathology underwent CT and MRI: 6 non-functioning adenomas, 2 Cushing's adenomas, 2 Conn's adenomas, 6 metastases, 3 cysts, 2 carcinomas (Cushing's syndrome), 1 lymphoma and 3 pheochromocytomas. Diagnosis was subsequently confirmed either at surgery, or autopsy, or with needle biopsy. In all cases normal adrenal glands and pathological lesions were showed by MRI. T1 signal intensity and mass diameter were compared with T2 signal intensity, represented by the intensity ratio between the adrenal mass vs normal hepatic parenchyma. MRI signal intensity, usually high in case of malignancy and low in adenomas, shows a mean value which is much wider than that referred to mass diameter evaluation (carcinoma is larger than adenoma); for this reason those findings have proved to be insufficiently accurate for adrenal tissue characterization, even for the evaluation of cysts and pheochromocytomas. In the same cases CT showed higher accuracy.


Subject(s)
Adenoma/diagnosis , Adrenal Gland Neoplasms/diagnosis , Carcinoma/diagnosis , Magnetic Resonance Imaging , Adenoma/diagnostic imaging , Adenoma/pathology , Adrenal Gland Diseases/diagnosis , Adrenal Gland Diseases/diagnostic imaging , Adrenal Gland Diseases/pathology , Adrenal Gland Neoplasms/pathology , Adrenal Gland Neoplasms/secondary , Adult , Aged , Carcinoma/diagnostic imaging , Carcinoma/pathology , Cushing Syndrome/diagnosis , Cushing Syndrome/diagnostic imaging , Cushing Syndrome/pathology , Cysts/diagnosis , Cysts/diagnostic imaging , Cysts/pathology , Diagnosis, Differential , Female , Humans , Lymphoma/diagnosis , Lymphoma/pathology , Male , Middle Aged , Pheochromocytoma/diagnosis , Pheochromocytoma/diagnostic imaging , Pheochromocytoma/pathology , Tomography, X-Ray Computed
11.
Minerva Med ; 79(1): 35-40, 1988 Jan.
Article in Italian | MEDLINE | ID: mdl-3340314

ABSTRACT

Given the disagreements in the literature over the extent of cardiac complications during urography it was decided to assess any arrhythmias following the injection of ionic and non-ionic contrast media and a placebo by means of 24 hours dynamic Holter monitoring. The results were subjected to meticulous statistical analysis and showed no connection between electrocardiographic alterations and the substance injected. The absence of statistical significance and the variability of the results suggest that alterations in the physiological parameters and/or arrhythmias arising during the administration of contrast media should be assessed with extreme caution.


Subject(s)
Contrast Media/adverse effects , Heart Rate/drug effects , Urography/adverse effects , Adolescent , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac/chemically induced , Chemical Phenomena , Chemistry , Electrocardiography , Female , Humans , Male , Middle Aged , Monitoring, Physiologic
12.
Radiol Med ; 75(1-2): 65-9, 1988.
Article in Italian | MEDLINE | ID: mdl-3279474

ABSTRACT

The authors report their experience in the study of renal transplant recipients by MR, in order to determine its clinical potentials. The main purpose of this work is to focus on MR patterns in relation to clinical findings of rejected or normally functioning kidney. Twenty-four patients were examined with a 0.5 T superconductive magnet, body coil, spin-echo pulse sequence (SE) and inversion-recovery (IR). MRI patterns could be seen in normally functioning kidneys and transplant rejections, while variable MRI findings were observed in transplants with acute tubular necrosis (ATN). In the normally functioning transplanted kidney there is a clear corticomedullary differentiation (CMD), and the extent of vascular penetration into the renal parenchyma is clearly seen. In transplant rejection, CMD is either diminished or absent, and there is no vascular penetration into the parenchyma; to differentiate acute from chronic rejections, the increase/decrease in renal size and the change in renal shape (spherical shape in acute transplant rejection) respectively must be observed. MRI proves thus to be useful in the study of renal transplants, even in case of questionable clinical findings, and in patients in whom renal biopsy is contraindicated.


Subject(s)
Kidney Transplantation , Magnetic Resonance Imaging , Adolescent , Adult , Aged , Exudates and Transudates , Female , Graft Rejection , Humans , Kidney/anatomy & histology , Kidney Diseases/diagnosis , Kidney Tubular Necrosis, Acute/pathology , Male , Middle Aged
13.
Minerva Med ; 78(24): 1797-804, 1987 Dec 31.
Article in Italian | MEDLINE | ID: mdl-3431726

ABSTRACT

Current usage of MR in the clinical study of adrenal pathology is assessed with a review of the advantages and limitations of this new imaging technique and a critical analysis of data deriving both from the literature and from personal experience. The possibility of a multiplanar study offered by MR permits a more accurate anatomical-topographical definition of the adrenal masses though it is not yet capable of the tissue characterisation that would diagnose the nature of the lesion, though it can differentiate between inert adenomas and metastases.


Subject(s)
Adrenal Gland Diseases/diagnosis , Magnetic Resonance Imaging , Adenoma/diagnosis , Adrenal Gland Neoplasms/diagnosis , Adrenal Gland Neoplasms/secondary , Adrenal Glands/pathology , Cysts/diagnosis , Diagnosis, Differential , Humans , Hyperplasia , Lipoma/diagnosis , Neuroblastoma/diagnosis , Pheochromocytoma/diagnosis
14.
Radiol Med ; 74(1-2): 81-7, 1987.
Article in Italian | MEDLINE | ID: mdl-3303176

ABSTRACT

The authors describe a new method for the treatment of pancreatic pseudocysts using a personal technique: the percutaneous pseudocystogastrostomy. Under US and fluoroscopy guidance at first a percutaneous drainage is introduced in the pseudocyst using a transgastric approach. For seven days the drainage catheter is flushed with antibiotic solution (Rifocin), then under fluoroscopy and endoscopy guidance doubled pig-tail catheter is placed with its curlend ends in the lumen of the stomach and pseudocyst respectively. After 60 days the double pig-tail catheter is removed endoscopically. Two patients with pancreatic pseudocysts were treated successful by this method. No complications or recurrences were observed.


Subject(s)
Catheters, Indwelling , Gastrostomy/methods , Pancreatic Cyst/therapy , Pancreatic Pseudocyst/therapy , Prostheses and Implants , Acute Disease , Adult , Catheterization/methods , Drainage , Humans , Male , Pancreatitis/complications , Tomography, X-Ray Computed , Ultrasonography
15.
Radiol Med ; 74(1-2): 23-9, 1987.
Article in Italian | MEDLINE | ID: mdl-3615974

ABSTRACT

Percutaneous insertion of ureteral stents is a widely accepted method for ureteral obstructions treatment. From 1981 to february 1986, we introduced 78 endoprostheses in 60 patients. Fifty-six with malignant tumours and 4 with benign stenoses. In 48 of those 60 patients follow-up is complete. In the patients with malignant obstructions the mean time of survival was 198 days. Twelve patients were still alive in february 1986, with a mean time of survival over 300 days. In 12 patients (25%) the stent became obstructed in a mean time of 96.8 days. The placement of ureteral stents offers an alternative treatment to the palliative urologic surgery.


Subject(s)
Prostheses and Implants , Ureteral Obstruction/therapy , Adult , Aged , Aged, 80 and over , Constriction, Pathologic/diagnostic imaging , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Female , Humans , Male , Middle Aged , Prosthesis Design , Radiography , Ureteral Obstruction/diagnostic imaging , Ureteral Obstruction/etiology , Urinary Calculi/complications , Urinary Calculi/diagnostic imaging
16.
Radiol Med ; 73(5): 383-5, 1987 May.
Article in Italian | MEDLINE | ID: mdl-3589011

ABSTRACT

In this perspective study the authors examined 57 patients to evaluate diagnostic accuracy of sequential angiourography (AUS) using spot-camera and image subtraction for the visualization of the vascular phase of the renal arteries. All the subjects underwent surgery or follow-up with other clinical and radiological methods. The results obtained with this technique, of low cost and simple execution, were satisfactory: accuracy 98%, sensitivity 100%, specificity 98%.


Subject(s)
Renal Artery/diagnostic imaging , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Urography/instrumentation , Vascular Diseases/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL