Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Publication year range
1.
Spine J ; 16(10): 1253-1262, 2016 10.
Article in English | MEDLINE | ID: mdl-27374111

ABSTRACT

BACKGROUND CONTEXT: Percutaneous vertebroplasty (PVP) is a minimally invasive surgical procedure and is frequently performed in humans who need surgical treatment of vertebral fractures. PVP involves cement injection into the vertebral body, thereby providing rapid and significant pain relief. PURPOSE: The testing of novel biomaterials depends on suitable animal models. The aim of this study was to develop a reproducible and safe model of PVP in sheep. STUDY DESIGN: This study used ex vivo and in vivo large animal model study (Merino sheep). METHODS: Ex vivo vertebroplasty was performed through a bilateral modified parapedicular access in 24 ovine lumbar hemivertebrae, divided into four groups (n=6). Cerament (Bone Support, Lund, Sweden) was the control material. In the experimental group, a novel composite was tested-Spine-Ghost-which consisted of an alpha-calcium sulfate matrix enriched with micrometric particles of mesoporous bioactive glass. All vertebrae were assessed by micro-computed tomography (micro-CT) and underwent mechanical testing. For the in vivo study, 16 sheep were randomly allocated into control and experimental groups (n=8), and underwent PVP using the same bone cements. All vertebrae were assessed postmortem by micro-CT, histology, and reverse transcription-polymerase chain reaction (rt-PCR). This work has been supported by the European Commission under the 7th Framework Programme for collaborative projects (600,000-650,000 USD). RESULTS: In the ex vivo model, the average defect volume was 1,275.46±219.29 mm3. Adequate defect filling with cement was observed. No mechanical failure was observed under loads which were higher than physiological. In the in vivo study, cardiorespiratory distress was observed in two animals, and one sheep presented mild neurologic deficits in the hind limbs before recovering. CONCLUSIONS: The model of PVP is considered suitable for preclinical in vivo studies, mimicking clinical application. All sheep recovered and completed a 6-month implantation period. There was no evidence of cement leakage into the vertebral foramen in the postmortem examination.


Subject(s)
Minimally Invasive Surgical Procedures/methods , Vertebroplasty/methods , Animals , Bone Cements/therapeutic use , Calcium Sulfate/therapeutic use , Disease Models, Animal , Drug Combinations , Durapatite/therapeutic use , Minimally Invasive Surgical Procedures/instrumentation , Sheep , Spinal Fractures/surgery , Vertebroplasty/instrumentation
2.
J Biomed Opt ; 19(3): 37006, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24687573

ABSTRACT

The purpose of the present study was to measure the intradiscal pressure signal of an anesthetized sheep under spontaneous breathing. An ultra-miniature fiber optic high-pressure sensor was implanted into the nucleus pulposus of the fifth lumbar intervertebral using a dorsolateral transforaminal approach. Results suggested the periodicity of the intradiscal pressure signal was similar to the mean respiratory rate of the animal. The average resting intradiscal pressure was also calculated and compared to available data.


Subject(s)
Biomechanical Phenomena/physiology , Intervertebral Disc/physiology , Monitoring, Physiologic/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Animals , Calibration , Female , Linear Models , Monitoring, Physiologic/methods , Pressure , Sheep
3.
J Biomed Biotechnol ; 2012: 613403, 2012.
Article in English | MEDLINE | ID: mdl-22701304

ABSTRACT

This in vivo study presents the preliminary results of the use of a novel piezoelectric actuator for orthopedic application. The innovative use of the converse piezoelectric effect to mechanically stimulate bone was achieved with polyvinylidene fluoride actuators implanted in osteotomy cuts in sheep femur and tibia. The biological response around the osteotomies was assessed through histology and histomorphometry in nondecalcified sections and histochemistry and immunohistochemistry in decalcified sections, namely, through Masson's trichrome, and labeling of osteopontin, proliferating cell nuclear antigen, and tartrate-resistant acid phosphatase. After one-month implantation, total bone area and new bone area were significantly higher around actuators when compared to static controls. Bone deposition rate was also significantly higher in the mechanically stimulated areas. In these areas, osteopontin increased expression was observed. The present in vivo study suggests that piezoelectric materials and the converse piezoelectric effect may be used to effectively stimulate bone growth.


Subject(s)
Femur/radiation effects , High-Energy Shock Waves , Osteogenesis/radiation effects , Tibia/radiation effects , Animals , Bone Development/radiation effects , Femur/growth & development , Femur/surgery , Male , Polyvinyls , Prostheses and Implants , Sheep , Tibia/growth & development , Tibia/surgery
4.
Nanoscale ; 2(12): 2855-63, 2010 Dec.
Article in English | MEDLINE | ID: mdl-20936241

ABSTRACT

As interest in using carbon nanotubes for developing biologically compatible systems continues to grow, biological inspiration is stimulating new directions for in vivo approaches. The ability to integrate nanotechnology-based systems in the body will provide greater successes if the implanted material is made to mimic elements of the biological milieu especially through tuning physical and chemical characteristics. Here, we demonstrate the highly successful capacity for in vivo implantation of a new carbon nanotube-based composite that is, itself, integrated with a hydroxyapatite-polymethyl methacrylate to create a nanocomposite. The success of this approach is grounded in finely tailoring the physical and chemical properties of this composite for the critical demands of biological integration. This is accomplished through controlling the surface modification scheme, which affects the interactions between carbon nanotubes and the hydroxyapatite-polymethyl methacrylate. Furthermore, we carefully examine cellular response with respect to adhesion and proliferation to examine in vitro compatibility capacity. Our results indicate that this new composite accelerates cell maturation through providing a mechanically competent bone matrix; this likely facilitates osteointegration in vivo. We believe that these results will have applications in a diversity of areas including carbon nanotube, regeneration, chemistry, and engineering research.


Subject(s)
Biomimetic Materials/chemistry , Nanotubes, Carbon/chemistry , Animals , Biomimetic Materials/therapeutic use , Bone and Bones/pathology , Cell Line, Tumor , Durapatite/chemistry , Durapatite/therapeutic use , Humans , Polymethyl Methacrylate/chemistry , Polymethyl Methacrylate/therapeutic use , Sheep
5.
Rev. bras. ortop ; 44(3): 260-265, maio-jun. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-524576

ABSTRACT

Este estudo teve como objectivo o desenvolvimento uma metodologia de fabrico rápido de implantes ortopédicos, em simultaneidade com a intervenção cirúrgica, considerando duas potenciais aplicações na área ortopédica: o fabrico de implantes anatomicamente adaptados e o fabrico de implantes para substituição de perdas ósseas. A inovação do trabalho desenvolvido consiste na obtenção in situ da geometria do implante, através da impressão directa de um material elastomérico (polivinilsiloxano) que permite obter com grande exactidão a geometria pretendida. Após digitalização do modelo obtido em material elastomérico, o implante final é fabricado por maquinagem recorrendo a um sistema de CAD/CAM dedicado. O implante após esterilização, pode ser colocado no paciente. O conceito foi desenvolvido com recurso a tecnologias disponíveis comercialmente e de baixo custo. O mesmo foi testado sob a forma de uma artroplastia da anca realizada in vivo numa ovelha. O acréscimo de tempo de cirurgia foi de 80 minutos sendo 40 directamente resultantes do processo de fabrico do implante. O sistema desenvolvido revelou-se eficiente no alcance dos objectivos propostos, possibilitando o fabrico de um implante durante um período de tempo perfeitamente compatível com o tempo de cirurgia.


This study, aimed the development of a methodology for rapid manufacture of orthopedic implants simultaneously with the surgical intervention, considering two potential applications in the fields of orthopedics: the manufacture of anatomically adapted implants and implants for bone loss replacement. This work innovation consists on the capitation of the in situ geometry of the implant by direct capture of the shape using an elastomeric material (polyvinylsiloxane) which allows fine detail and great accuracy of the geometry. After scanning the elastomeric specimen, the implant is obtained by machining using a CNC milling machine programmed with a dedicated CAD/CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time.


Subject(s)
Humans , Arthroplasty , Prostheses and Implants
6.
Rev Bras Ortop ; 44(3): 260-5, 2009 Jan.
Article in English | MEDLINE | ID: mdl-27004181

ABSTRACT

This study, aimed the development of a methodology for rapid manufacture of orthopedic implants simultaneously with the surgical intervention, considering two potential applications in the fields of orthopedics: the manufacture of anatomically adapted implants and implants for bone loss replacement. This work innovation consists on the capitation of the in situ geometry of the implant by direct capture of the shape using an elastomeric material (polyvinylsiloxane) which allows fine detail and great accuracy of the geometry. After scanning the elastomeric specimen, the implant is obtained by machining using a CNC milling machine programmed with a dedicated CAD/CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time.

7.
J Chem Ecol ; 34(3): 388-97, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18288539

ABSTRACT

Saliva provides a medium for short-term adaptation to changes in diet composition, namely, the presence of plant secondary metabolites. Salivary proteins have biological functions that have particular influence on oral homeostasis, taste, and digestive function. Some salivary proteins, such as proline-rich proteins, are present in browsers but absent in grazers. Despite the significance of salivary proteins, their expression patterns in many herbivores are unknown. We investigated the sodium dodecyl sulfate-polyacrylamide gel electrophoresis profile of parotid salivary proteins from two domesticated species, one a grazer, the sheep, Ovis aries, and the other a mixed feeder, the goat, Capra hircus, both fed on the same conventional diet. With 12.5% polyacrylamide linear gels, we observed uniform patterns of salivary proteins within the two species. In the goat profile, 21 major bands were observed, and 19 in the sheep profile. Each band was subjected to peptide mass fingerprinting for purposes of identification, allowing for 16 successful protein identifications. Marked differences were observed between the species in the region of 25-35 kDa molecular weights: one band was present in significantly different intensities; three bands were present only in goats; and one band was present only in sheep. This is the first report of a comparison of the protein salivary composition of sheep and goats and suggests that future research should be conducted to reveal a physiological function for salivary proteins related to the differences in feeding behavior of these species.


Subject(s)
Goats , Salivary Proteins and Peptides/analysis , Sheep , Animals , Electrophoresis, Polyacrylamide Gel , Parotid Gland/metabolism , Saliva/metabolism , Salivary Proteins and Peptides/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...