Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
J La State Med Soc ; 167(4): 196-7, 2015.
Article in English | MEDLINE | ID: mdl-27159515

ABSTRACT

There is a sinus P wave in front of each QRS, and the rate is 122 beats/min. The QRS voltage is large and meets many criteria for left ventricular hypertrophy: RI > 13 mm (1.3 mV); RaVF > 19 mm; SaVR > 14 mm; SV1 > 24 mm; SV2 > 30 mm; RV6 > 26 mm; RV6 > RV5; SV1 + RV5 or RV6 > 35 mm; SV2 + RV5 or RV6 > 45 mm; RaVL + SV3 > 20 mm in a woman.1 In addition, there are two non-voltage criteria for LVH: QRS duration = 0.11 s and typical repolarization changes: J-point depression with a downsloping ST segment into an inverted T wave and a more rapid upslope back to the baseline. The prolonged QRS duration and repolarization changes are also typical of incomplete left bundle branch block (ILBBB). LVH is present in most patients with complete LBBB,2,3 and probably in most with ILBBB. The patient underwent aortic valvotomy at age 5 to relieve congenital stenosis. Although different valvular morphologies can result in aortic stenosis, when hemodynamically significant stenosis is present in infancy or early childhood the valve is usually unicuspid/unicommissural. Aortic valvotomy can greatly reduce the left ventricular outflow obstruction in such patients, but the majority eventually need reoperation. This usually means aortic valve replacement. This woman now has severe aortic stenosis and regurgitation with not only left but also right ventricular failure, which is a late development with pure aortic valve disease. She needs aortic valve replacement. Unfortunately having one severe disease does not preclude another, and her operative course will be complicated by multiple sclerosis which she developed some 12 years ago.


Subject(s)
Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Electrocardiography , Adult , Aortic Valve Stenosis/congenital , Aortic Valve Stenosis/surgery , Cardiac Surgical Procedures , Child, Preschool , Female , Humans , Postoperative Period
4.
Echocardiography ; 26(5): 598-609, 2009 May.
Article in English | MEDLINE | ID: mdl-19438700

ABSTRACT

This case series demonstrates the incremental value of three-dimensional transthoracic echocardiography (3D TTE) over two-dimensional transthoracic echocardiography (2D TTE) in the assessment of 11 patients with right ventricular (RV) masses or mass-like lesions (three cases of RV thrombus, one myxoma, one fibroma, one lipoma, one chordoma, and one sarcoma and three cases of RV noncompaction, which are considered to be mass-like in nature). 3D TTE was of incremental value in the assessment of these masses in that 3D TTE has the capacity to section the mass and view it from multiple angles, giving the examiner a more comprehensive assessment of the mass. This was particularly helpful in the cases of thrombi, as the presence of echolucencies indicated clot lysis. In addition, certainty in the number of thrombi present was an advantage of 3D TTE. Also, sectioning of cardiac tumors allowed more confidence in narrowing the differential diagnosis of the etiology of the mass. In addition, 3D TTE allowed us to identify precise location of the attachments of the masses as well as to determine whether there were mobile components to the mass. Another noteworthy advantage of 3D TTE was that the volumes of the masses could be calculated. Additionally, the findings by 3D TTE correlated well with pathologic examination of RV tumors, and some of the masses measured larger by 3D TTE than by 2D TTE, which was also validated in one case by surgery. As in the case of RV fibroma, another advantage was that 3D TTE actually identified more masses than 2D TTE. RV noncompaction was also well studied, and the assessment with 3D TTE helped to give a more definitive diagnosis in these patients.


Subject(s)
Echocardiography, Three-Dimensional/methods , Heart Neoplasms/diagnostic imaging , Heart Ventricles/diagnostic imaging , Thrombosis/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Adult , Computer Systems , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
5.
Echocardiography ; 25(10): 1138-44, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18986398

ABSTRACT

Five adult patients with Takotsubo cardiomyopathy (TC) diagnosed by usual criteria were studied with velocity vector imaging (VVI) on admission and at follow-up, when their LV function had improved, as assessed by 2D TTE wall-motion score (WMS) index. Averaged peak segmental longitudinal strain (S) in systole, and velocity (V) and strain rate (SR) in both systole and diastole were measured from apical 4- (A4C) and 2-chamber views (A2C) in all patients. The data obtained by VVI were analyzed separately for involved and uninvolved segments, which were independently assessed by WMS. In the involved segments, systolic S, V, SR, and diastolic SR improved (P-value < 0.05) on follow-up. Diastolic V showed a trend toward improvement but did not reach statistical significance. In the uninvolved segments, none of the parameters improved significantly either during systole or diastole. In three of these five patients, left atrial (LA) walls were also studied by placing region of interest (ROI) points in the middle of each wall. Peak segmental LA systolic and diastolic V and SR as well as systolic S were obtained for both involved and uninvolved LA walls which were assessed independently using WMS similar to LV. In the involved LA walls, none of the atrial systolic and diastolic parameters changed significantly but all parameters with the exception of systolic V showed a tendency toward improvement during follow-up. Among the uninvolved LA walls, none changed significantly but atrial systolic SR and, diastolic V and SR tended to increase during follow-up. Our retrospective study using VVI demonstrates that TC patients also have LV systolic and diastolic longitudinal dysfunction, not just systolic radial dysfunction as assessed by traditional 2D TTE indices. Longitudinal LA dysfunction may also be present.


Subject(s)
Atrial Function, Left , Blood Flow Velocity/physiology , Heart Ventricles/diagnostic imaging , Takotsubo Cardiomyopathy/diagnostic imaging , Ultrasonography , Aged , Diastole/physiology , Follow-Up Studies , Humans , Middle Aged , Systole/physiology , Ultrasonography/methods
6.
Echocardiography ; 25(8): 911-7, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18986421

ABSTRACT

There is no gold standard for the measurement of pulmonary regurgitation (PR) severity. Two-dimensional (2D) transthoracic echocardiography is most commonly used to quantify PR severity using color Doppler criteria for aortic regurgitation. However, this method is limited by visualization of only one or two dimensions of the proximal PR jet or vena contracta (VC) precluding accurate assessment of its shape or size. This limitation would be expected to be obviated by three-dimensional (3D) transthoracic echocardiography, which could provide a more accurate quantitative assessment of PR severity. This study evaluated 82 adult patients with PR using 2D and 3D. PR VC area by 3D was obtained by planimetry by positioning the cropping plane exactly parallel to the VC, which was viewed en face by cropping of the 3D data set. Regurgitant volumes were calculated by 2D (assuming a circular VC) and by 3D as a product of the VC and velocity time integral obtained by color Doppler-guided conventional Doppler interrogation of the PR jet.The 3D VC area correlated with 2D jet width (JW)/right ventricular outflow tract (RVOT) width (r = 0.71) and 2D VC area (r = 0.79). 3D JW/RVOT width correlated with 2D JW/RVOT (r = 0.87). 3D regurgitant volumes also correlated with 2D regurgitant volumes (r = 0.76). The 3D VC values of <0.20, 0.20-0.45, 0.46-1.15, and >1.15 cm(2) and regurgitant volumes of <15 ml, 15-50 ml, 51-115 ml, and >115 ml were effective as cutoffs for grades 1, 2, 3, and 4 PR, respectively. In conclusion, quantification of 3D VC area and regurgitant volumes correlate reasonably well with the current 2D methods for measurement of PR. Since 3D visualizes PR VC in three dimensions, it would be expected to provide a more accurate and more quantitative assessment of PR severity as compared to 2D.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Pulmonary Valve Insufficiency/diagnostic imaging , Adult , Aged , Aged, 80 and over , Computer Systems , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
7.
Echocardiography ; 25(8): 918-24, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18986422

ABSTRACT

OBJECTIVE: Our objective was to compare the utility of combined two-dimensional (2D) transthoracic echocardiography (TTE) and three-dimensional (3D) TTE versus 2D transesophageal echocardiography (TEE) in evaluation of the left atrium (LA) and LA appendage (LAA) for clot. BACKGROUND: 2DTEE, usually performed to visualize the LAA, is semi-invasive and not without risks. With improved technology the LAA has been increasingly visualized by 2DTTE and 3DTTE in many patients. METHODS: We compared combined 2DTTE and 3DTTE with 2DTEE in evaluating the LA/LAA for a thrombus. Ninety-two patients underwent 2DTTE, 3DTTE, and 2DTEE. An additional 20 patients, in whom TEE could not be performed, underwent 2DTTE and 3DTTE. RESULTS: LA and LAA could be visualized in all patients. Of 92 patients studied, 74 had no thrombus and 7 had thrombus in the LAA by all modalities. Eleven patients, 9 with atrial fibrillation (AF), had a suspected thrombus by 2DTEE, but 3DTTE cropping clearly showed these to be prominent pectinate muscles which were seen in short axis on 2DTEE as rounded echo dense masses and therefore mimicked thrombi. These 9 patients with AF underwent successful cardioversion without any complications. Of the 20 patients in whom TEE could not be performed, 19 had no thrombus in the LA/LAA and 1 had a clot in the LAA. These 19 patients underwent successful cardioversion without complications. CONCLUSIONS: Our preliminary study suggests that combined 2DTTE and 3DTTE has comparable accuracy to TEE in evaluating the LA and LAA for thrombus. In some patients TEE, but not 3DTTE, may misdiagnose pectinate musculature as thrombus.


Subject(s)
Atrial Appendage/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Heart Atria/diagnostic imaging , Pulmonary Valve Insufficiency/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
8.
Echocardiography ; 25(9): 1004-6, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18771551

ABSTRACT

We report an adult with a discrete subaortic membrane in whom two-dimensional transthoracic Doppler echocardiography demonstrated peak and mean gradients of 64 and 33 mmHg, respectively in the left ventricular outflow tract (LVOT) and a calculated orifice area by continuity equation of 1.14 cm(2) consistent with significant obstruction. However, by direct en face visualization of the LVOT at the level of the membrane by live/real time three-dimensional transthoracic echocardiography (3D TTE), a larger orifice measuring 2.29 cm(2) was seen and was indicative of no significant obstruction. This finding was confirmed at cardiac catheterization, which showed insignificant obstruction.


Subject(s)
Aorta/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Diagnostic Errors/prevention & control , Echocardiography, Doppler/methods , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Adult , Female , Humans
9.
Echocardiography ; 25(5): 537-9, 2008 May.
Article in English | MEDLINE | ID: mdl-18422661

ABSTRACT

We describe echocardiographic findings in an elderly patient with histologically proven amorphous tumor involving the posterior mitral annulus, mimicking a vegetation.


Subject(s)
Calcinosis/diagnostic imaging , Heart Neoplasms/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Mitral Valve/pathology , Aged, 80 and over , Diagnosis, Differential , Echocardiography , Electrocardiography , Endocarditis/diagnostic imaging , Female , Humans
10.
Echocardiography ; 25(4): 440-2, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18366356

ABSTRACT

We describe live/real time three-dimensional transthoracic echocardiographic features of a chordoma metastatic to the heart and correlate its appearance with the surgical pathology.


Subject(s)
Chondroma/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Heart Neoplasms/secondary , Spinal Neoplasms/pathology , Diagnosis, Differential , Female , Heart Neoplasms/diagnostic imaging , Heart Ventricles/diagnostic imaging , Humans , Middle Aged , Time Factors
11.
Echocardiography ; 24(10): 1099-104, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18001367

ABSTRACT

A new tool has been recently introduced to the echocardiography armamentarium, live/real time three-dimensional (3D) transesophageal echocardiography (TEE). In these cases, we describe our initial experience in 13 patients studied intraoperatively and in the echocardiography suite. This important technology promises improved anatomic definition, diagnostic confidence, and novel views of the complicated cardiovascular pathology encountered in common clinical practice.


Subject(s)
Aortic Diseases/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Diseases/diagnostic imaging , Adult , Aged , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Reproducibility of Results
12.
Echocardiography ; 24(8): 875-82, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17767540

ABSTRACT

We describe the usefulness of contrast echocardiography and live/real time three-dimensional transthoracic echocardiography in characterizing the normal structures imaged posterior to the proximal ascending aorta as superior vena cava, right pulmonary artery, or both.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Echocardiography, Three-Dimensional , Pulmonary Artery/diagnostic imaging , Vena Cava, Superior/diagnostic imaging , Adult , Aged , Contrast Media/administration & dosage , Female , Humans , Injections, Intravenous , Male , Middle Aged , Sodium Chloride/administration & dosage
14.
Echocardiography ; 24(5): 541-52, 2007 May.
Article in English | MEDLINE | ID: mdl-17456074

ABSTRACT

Twenty-nine patients with different tricuspid valve (TV) pathologies were studied by both two-dimensional transthoracic (2DTTE) and live/real time three-dimensional transthoracic echocardiography (3DTTE). A major contribution of 3DTTE over 2DTTE was the en face visualization of all three leaflets of the TV in all patients. This allowed accurate assessment of TV orifice area in patients with TV stenosis and carcinoid disease. Loss of TV leaflet tissue, defects in TV leaflets and size of TV systolic non-coaptation could also be delineated and resulted in identifying the mechanism of tricuspid regurgitation (TR) in patients with Ebstein's anomaly and rheumatic heart disease. Prolapse of TV leaflets could also be well visualized and enabled us to develop a schema for systematic assessment of individual segment prolapse which could help in surgical planning. The exact sites of chordae rupture in patients with flail TV as well as right ventricular papillary muscle rupture could be well seen by 3DTTE. 3DTTE also permitted sectioning of various TV masses for more specific diagnosis of their nature. In addition, color Doppler 3DTTE provided an estimate of quantitative evaluation of TR severity, since the exact shape and size of the vena contracta could be accurately assessed. In conclusion, our preliminary experience with 3DTTE has demonstrated substantial incremental value over 2DTTE in the assessment of various TV pathologies.


Subject(s)
Computer Systems , Echocardiography/methods , Image Processing, Computer-Assisted , Tricuspid Valve Insufficiency/pathology , Tricuspid Valve Prolapse/pathology , Tricuspid Valve Stenosis/pathology , Adult , Aged , Child, Preschool , Echocardiography, Doppler, Color/methods , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Severity of Illness Index , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Prolapse/diagnostic imaging , Tricuspid Valve Stenosis/diagnostic imaging
16.
Echocardiography ; 24(3): 272-3, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17313641

ABSTRACT

We report a patient with disseminated sepsis in whom a large vegetation involving the tricuspid valve was seen on a routine nongated computed tomography (CT) study emphasizing the potential role of CT scan in endocarditis.


Subject(s)
Endocarditis, Bacterial/diagnostic imaging , Staphylococcal Infections/diagnostic imaging , Tomography, X-Ray Computed/methods , Tricuspid Valve/microbiology , Adult , Endocarditis, Bacterial/drug therapy , Endocarditis, Bacterial/microbiology , Humans , Male , Staphylococcal Infections/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...