Cardiology ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38714182

ABSTRACT

INTRODUCTION: This pooled analysis was conducted to assess the clinical safety and performance of the Supra family (Sahajanand Medical Technologies Ltd., Surat, India) of sirolimus-eluting stents (SES) in patients with acute coronary syndromes (ACS) including ST segment elevation myocardial infarction (STEMI) from two real-world all-comers Indian registries at one-year. METHODS: We evaluated 1824 patients with ACS who underwent percutaneous coronary intervention with the Supra family of SES from two real-world Indian registries (891 patients from T-Flex registry and 933 patients from Tetriflex real-world registry). The primary endpoint was the incidence of target lesion failure (TLF) defined as a composite of cardiac death, target vessel myocardial infarction (TV-MI), and target lesion revascularization (TLR) at one-year follow-up. The safety endpoint was stent thrombosis at one-year follow-up. RESULTS: Among a total of 1824 patients with ACS, 689 (37.8%) patients presented with STEMI. In ACS and STEMI groups, 47.6% and 41.8% patients had multi-vessel disease, respectively. Of 2128 lesions in ACS group, 76.7% lesions were type B2/C and 16.2% lesions were totally occluded. In the STEMI group, out of 784 treated lesions, 76.7% were type B2/C lesions and 21.9% were totally occluded. At one-year follow-up, incidence of TLF was 5.3% (cardiac death: 0.9%, TV-MI: 2.5%, TLR: 1.9%) in patients with ACS and 6.2% (cardiac death: 1.4%, TV-MI: 2.1%, TLR: 2.7%) in patients with STEMI. The one-year rate of definite/probable stent thrombosis were 0.3% and 0.7% in patients with ACS and STEMI, respectively. CONCLUSION: This patient-level pooled analysis provides evidence for the safe and effective use of the Supra family of SES in complex patient populations such as ACS and even in STEMI with favourable rates of TLF and stent thrombosis at one-year follow-up.

2.
Cureus ; 15(7): e41940, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37588334

ABSTRACT

Electric injuries are uncommon but can lead to numerous long-term complications as well as death. Occupational exposure is the most common cause of injury among the affected population. Both low-voltage and high-voltage electrocution are associated with significant morbidity and mortality. Patients with certain presentations are at a high risk of arrhythmia post-injury. Here, we discuss the presentation and management of high-voltage electrocution in a 35-year-old electrician.

4.
Anatol J Cardiol ; 25(10): 706-715, 2021 10.
Article in English | MEDLINE | ID: mdl-34622785

ABSTRACT

OBJECTIVE: T-Flex registry was designed to investigate the safety and clinical performance of the ultrathin (60 µm) strut biodegradable polymer-coated sirolimus-eluting stent (SES) with a unique long dual Z (LDZ) link design on a cobalt-chromium stent platform (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) in a real-world all-comer population including high-risk subgroups. METHODS: This was an observational, multicenter, single-arm, and investigator-initiated retrospective registry. A total of 1,203 patients treated with an ultrathin biodegradable polymer-coated SES, irrespective of lesion complexity, comorbidities, and acute presentation were analyzed from May 2016 to January 2017. The primary endpoint was the one-year incidence of target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction (TV-MI), and clinically-indicated target lesion revascularization (CI-TLR). Stent thrombosis was assessed as an additional safety endpoint. RESULTS: At the one-year follow-up, TLF was observed in 3.8% [95% confidence interval (CI) 2.9-5.1] patients, composed of 0.6% (95% CI: 0.3-1.3) cardiac death, 1.3% (95% CI: 0.8-2.2) TV-MI, and 1.9% (95% CI: 1.3-2.9) CI-TLR. In the high-risk subgroups, TLF at one-year was 6.8% (95% CI: 4.6-9.8) in patients with diabetes, 5.2% (95% CI: 3.4-8) in patients with small-vessel disease, 6.1% (95% CI: 3.9-9.6) in patients with ST-elevation myocardial infarction, and 4.5% (95% CI: 2.4-8.3) in patients with total occlusion. During follow-up, stent thrombosis was reported in 0.8% (95% CI: 0.4-1.5) patients in the overall population. CONCLUSION: Low event rates of TLF and stent thrombosis at one-year follow-up indicate that this ultrathin biodegradable polymer-coated SES has encouraging safety and clinical performance in real-world all-comer populations as well as in high-risk subgroups.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Coronary Artery Disease/therapy , Humans , Polymers , Registries , Retrospective Studies , Risk Factors , Sirolimus , Treatment Outcome