Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Dent Traumatol ; 25(3): 338-40, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19583581

ABSTRACT

A 42-year-old woman had sustained a severe dental trauma with an alveolar fracture after an epileptic attack. A tooth block 31, 32, 33 and 34 was dislocated about 7 mm in buccal direction. Panoramic X-rays and CT-scan disclosed the alveolar fracture without total disjunction of the fragment. An orthodontic appliance was used to reduce the fracture with gentle forces during a 5-month period. Normal function was established and the teeth remained vital.


Subject(s)
Alveolar Process/injuries , Fracture Fixation/instrumentation , Mandibular Fractures/therapy , Orthodontic Appliances , Adult , Female , Fracture Fixation/methods , Humans , Treatment Outcome
2.
Anal Chem ; 79(5): 2137-49, 2007 Mar 01.
Article in English | MEDLINE | ID: mdl-17269654

ABSTRACT

A series of fluorophores with single-exponential fluorescence decays in liquid solution at 20 degrees C were measured independently by nine laboratories using single-photon timing and multifrequency phase and modulation fluorometry instruments with lasers as excitation source. The dyes that can serve as fluorescence lifetime standards for time-domain and frequency-domain measurements are all commercially available, are photostable under the conditions of the measurements, and are soluble in solvents of spectroscopic quality (methanol, cyclohexane, water). These lifetime standards are anthracene, 9-cyanoanthracene, 9,10-diphenylanthracene, N-methylcarbazole, coumarin 153, erythrosin B, N-acetyl-l-tryptophanamide, 1,4-bis(5-phenyloxazol-2-yl)benzene, 2,5-diphenyloxazole, rhodamine B, rubrene, N-(3-sulfopropyl)acridinium, and 1,4-diphenylbenzene. At 20 degrees C, the fluorescence lifetimes vary from 89 ps to 31.2 ns, depending on fluorescent dye and solvent, which is a useful range for modern pico- and nanosecond time-domain or mega- to gigahertz frequency-domain instrumentation. The decay times are independent of the excitation and emission wavelengths. Dependent on the structure of the dye and the solvent, the excitation wavelengths used range from 284 to 575 nm, the emission from 330 to 630 nm. These lifetime standards may be used to either calibrate or test the resolution of time- and frequency-domain instrumentation or as reference compounds to eliminate the color effect in photomultiplier tubes. Statistical analyses by means of two-sample charts indicate that there is no laboratory bias in the lifetime determinations. Moreover, statistical tests show that there is an excellent correlation between the lifetimes estimated by the time-domain and frequency-domain fluorometries. Comprehensive tables compiling the results for 20 (fluorescence lifetime standard/solvent) combinations are given.


Subject(s)
Luminescent Measurements/standards , Spectrometry, Fluorescence/standards , Fluorescence , Fluorescent Dyes/chemistry , Solvents/chemistry , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...