1.
J Sep Sci ; 40(3): 779-788, 2017 02.
Article in English | MEDLINE | ID: mdl-27868374

ABSTRACT

Many bioanalytical methods rely on electrophoretic separation of structurally labile and surface active biomolecules such as proteins and peptides. Often poor separation efficiency is due to surface adsorption processes leading to protein denaturation and surface fouling in the separation channel. Flexible and reliable approaches for preventing unwanted protein adsorption in separation science are thus in high demand. We therefore present new coating approaches based on an automated in-capillary surface-initiated atom transfer radical polymerization process (covalent coating) as well as by electrostatically adsorbing a presynthesized polymer leading to functionalized molecular brushes. The electroosmotic flow was measured following each step of the covalent coating procedure providing a detailed characterization and quality control. Both approaches resulted in good fouling resistance against the four model proteins cytochrome c, myoglobin, ovalbumin, and human serum albumin in the pH range 3.4-8.4. Further, even samples containing 10% v/v plasma derived from human blood did not show signs of adsorbing to the coated capillaries. The covalent as well as the electrostatically adsorbed coating were both found to be stable and provided almost complete suppression of the electroosmotic flow in the pH range 3.4-8.4. The coating procedures may easily be integrated in fully automated capillary electrophoresis methodologies.


Subject(s)
Blood Chemical Analysis/methods , Electrophoresis, Capillary/instrumentation , Polyethylene Glycols/chemistry , Adsorption , Blood Chemical Analysis/instrumentation , Cytochromes c/blood , Humans , Myoglobin/blood , Ovalbumin/blood , Proteins/metabolism , Serum Albumin/analysis , Silicon Dioxide/chemistry
2.
Anal Chem ; 88(18): 9056-61, 2016 09 20.
Article in English | MEDLINE | ID: mdl-27571264

ABSTRACT

Detection of immune responses is important in the diagnosis of many diseases. For example, the detection of circulating autoantibodies against double-stranded DNA (dsDNA) is used in the diagnosis of Systemic Lupus Erythematosus (SLE). It is, however, difficult to reach satisfactory sensitivity, specificity, and accuracy with established assays. Also, existing methodologies for quantification of autoantibodies are challenging to transfer to a point-of-care setting. Here we present the use of flow-induced dispersion analysis (FIDA) for rapid (minutes) measurement of autoantibodies against dsDNA. The assay is based on Taylor dispersion analysis (TDA) and is fully automated with the use of standard capillary electrophoresis (CE) based equipment employing fluorescence detection. It is robust toward matrix effects as demonstrated by the direct analysis of samples composed of up to 85% plasma derived from human blood samples, and it allows for flexible exchange of the DNA sequences used to probe for the autoantibodies. Plasma samples from SLE positive patients were analyzed using the new FIDA methodology as well as by standard indirect immunofluorescence and solid-phase immunoassays. Interestingly, the patient antibodies bound DNA sequences with different affinities, suggesting pronounced heterogeneity among autoantibodies produced in SLE. The FIDA based methodology is a new approach for autoantibody detection and holds promise for being used for patient stratification and monitoring of disease activity.


Subject(s)
Antibodies, Antinuclear/immunology , DNA/immunology , Electrophoresis, Capillary/instrumentation , Immunoassay/instrumentation , Lupus Erythematosus, Systemic/diagnosis , Antibodies, Antinuclear/blood , Enzyme-Linked Immunosorbent Assay , Equipment Design , Humans , Lupus Erythematosus, Systemic/blood , Lupus Erythematosus, Systemic/immunology , Patient Satisfaction
3.
Analyst ; 140(13): 4365-9, 2015 Jul 07.
Article in English | MEDLINE | ID: mdl-26031223

ABSTRACT

Rapid and sensitive quantification of protein based biomarkers and drugs is a substantial challenge in diagnostics and biopharmaceutical drug development. Current technologies, such as ELISA, are characterized by being slow (hours), requiring relatively large amounts of sample and being subject to cumbersome and expensive assay development. In this work a new approach for quantification based on changes in diffusivity is presented. The apparent diffusivity of an indicator molecule interacting with the protein of interest is determined by Taylor Dispersion Analysis (TDA) in a hydrodynamic flow system. In the presence of the analyte the apparent diffusivity of the indicator changes due to complexation. This change in diffusivity is used to quantify the analyte. This approach, termed Flow Induced Dispersion Analysis (FIDA), is characterized by being fast (minutes), selective (quantification is possible in a blood plasma matrix), fully automated, and being subject to a simple assay development. FIDA is demonstrated for quantification of the protein Human Serum Albumin (HSA) in human plasma as well as for quantification of an antibody against HSA. The sensitivity of the FIDA assay depends on the indicator-analyte dissociation constant which in favourable cases is in the sub-nanomolar to picomolar range for antibody-antigen interactions.


Subject(s)
Blood Proteins/analysis , Flow Injection Analysis/methods , Plasma/chemistry , Humans , Time Factors