Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Hip Int ; 19(2): 102-8, 2009.
Article in English | MEDLINE | ID: mdl-19462365

ABSTRACT

We retrospectively reviewed the clinical, radiographic, and survivorship outcomes in a series of 180 patients that underwent 204 primary Total Hip Arthroplasties with the use of a second generation threaded hydroxyapatite-coated acetabular cup that was implanted without any supplementary supporting screws. At an average follow-up period of 10.2 (range: 8-14) years, one hundred and seventy-four patients (198 cups) were available for assessment. All patients underwent detailed physical and radiographic examination; their functional status was evaluated according to the Harris Hip Score (HHS). Following their digitization, all radiographs were further reviewed in order to determine the existence of any migration of the acetabular cup. Osteolytic lesions, radiolucent lines or zones of increased bone density were also recorded and classified according to the system of DeLee & Charnley. The modified Engh's criteria were used in order to evaluate the stability of the prosthesis. The patients' mean HHS at their latest follow-up visit (97.24 points) was statistically significantly better than the preoperative mean score of 40.31 points (p<0.001). Radiographic analysis showed "stable with bone ingrowth" fixation (modified Engh's criteria) of all implants with no significant migration of the cup (mean cranial migration: 0.597 mm, mean horizontal migration: 0.607 mm, mean observed difference of the cup's inclination angle: 0.26 degrees). No areas of significant osteolysis were found. The cumulative survival rate of the implants was 97.05%. Our results suggest that second generation hydroxyapatite-coated threaded acetabular cups can be successfully implanted (and achieve excellent results) without the use of any supplementary supporting screws.


Subject(s)
Coated Materials, Biocompatible , Durapatite , Hip Prosthesis , Prosthesis Design , Adult , Aged , Equipment Failure Analysis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies
2.
J Arthroplasty ; 24(3): 414-20, 2009 Apr.
Article in English | MEDLINE | ID: mdl-18555655

ABSTRACT

From 1998 until 2004, we performed 26 consecutive cementless total hip arthoplasties in 15 patients who had developed advanced avascular necrosis of the femoral head after allogenic bone marrow transplantation. The average age at transplantation was 31.1 years, and the mean age at implantation was 33.6 years. Follow-up period ranged from 2 to 8 years with an average of 56.4 months. The mean D'Aubigne-Postel score improved from 7.5 points preoperatively to 17 points postoperatively. The overall result was excellent in 92.3%, good in 3.8%, and fair in 3.8% of cases. There were no radiological signs of components loosening and no severe complications. Cementless total hip arthroplasty appears as a favorable alternative for the treatment of avascular necrosis of the femoral heads after allogenic bone marrow transplantation.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Marrow Transplantation/adverse effects , Femur Head Necrosis/surgery , Glucocorticoids/adverse effects , Hematologic Diseases/surgery , Adolescent , Adult , Antineoplastic Agents/therapeutic use , Bone Cements , Femur Head Necrosis/etiology , Graft vs Host Disease/drug therapy , Graft vs Host Disease/etiology , Hematologic Diseases/drug therapy , Humans , Middle Aged , Transplantation, Homologous , Young Adult
3.
J Arthroplasty ; 24(2): 168-74, 2009 Feb.
Article in English | MEDLINE | ID: mdl-18534474

ABSTRACT

From 1985 to 2001, the Burch-Schneider antiprotrusio cage (B-S APC) was implanted in 57 cases (55 patients) with massive acetabular deficiency. The B-S APC survived until the last review 5 to 21 years after operation in 89.5% of the cases, produced substantial pain relief, and increased range of hip motion and walking capacity. The 10.5% failure rate was due to aseptic loosening in 2 cases and mechanical failure in 4 cases. It appears that application of the B-S APC in extensive acetabular deficiency presents a durable solution provided that proper indications and technique are used.


Subject(s)
Acetabulum/physiopathology , Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Adult , Aged , Bone Screws , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Kaplan-Meier Estimate , Longitudinal Studies , Male , Middle Aged , Polyethylene , Radiography , Range of Motion, Articular/physiology , Retrospective Studies , Treatment Outcome
4.
J Orthop Surg Res ; 3: 9, 2008 Feb 22.
Article in English | MEDLINE | ID: mdl-18294381

ABSTRACT

BACKGROUND: Tension band wiring (TBW) remains the most common operative technique for the internal fixation of olecranon fractures despite the potential occurrence of subjective complaints due to subcutaneous position of the hardware. Aim of this long term retrospective study was to evaluate the elbow function and the patient-rated outcome after TBW fixation of olecranon fractures. METHODS: We reviewed 62 patients (33 men and 29 women) with an average age of 48.6 years (range, 18-85 years) who underwent TBW osteosynthesis for isolated olecranon fractures. All patients were assessed both clinically with measurement of flexion-extension and pronation-supination arcs and radiologically with elbow X-Rays. Functional outcome was estimated using the Mayo Elbow Performance Score (MEPS), Visual Analogue Scale (VAS) subjective pain score and VAS patient satisfaction score. Follow up: 6-13 years (average 8.2 years). RESULTS: There was a higher prevalence of fractures among men until the 5th decade of life and among women in elderly (p = 0.032). Slip or simple fall onto the arm was the main mechanism of injury for 38 fractures (61.3%) while high energy trauma, such as fall from a height (> 2 m) or road accident, was reported in 24 fractures (38.7%). Hardware removal performed in 51 patients (82.3%) but 34 of them (66.6% of removals) were still complaining for mild pain during daily activities. The incidence of pin migration and loosening was not statistically decreased when penetration of the anterior ulnar cortex was accomplished (p = 0.304). Supination was more often affected than pronation (p = 0.027). According to MEPS, 53 patients (85.5%) had a good to excellent result, 6 (9.7%) fair and 3 (4.8%) poor result. The average satisfaction rating was 9.3 out of 10 (range, 6-10) with 31 patients (50%) to remain completely satisfied from the final result. Degenerative changes recorded in 30 elbows (48.4%). However, no correlation could be found between radiographic findings and MEPS (p = 0.073). CONCLUSION: Tension band wiring fixation remains the "gold standard" for the treatment of displaced and minimally comminuted olecranon fractures. In long term, low levels of pain may be evident regardless of whether the metalware is removed and degenerative changes have been developed.

5.
J Arthroplasty ; 20(4): 436-42, 2005 Jun.
Article in English | MEDLINE | ID: mdl-16124958

ABSTRACT

A total of 233 Autophor 900-S fully porous coated stems were implanted in 220 patients with an average age of 47.5 years and an average follow-up of 13.5 years. The mean d' Aubigne-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (P < .001). The overall result was excellent in 74.6%, good in 18.1%, fair in 5.8%, and poor in 1.5% of cases. One hip was revised for septic and two for aseptic loosening. The overall survival rate of this prosthesis was 98.1% in 17 years. The Autophor 900-S femoral stem has offered a very satisfactory clinical outcome together with considerable prosthesis longevity in the young patient population studied. It combines adequate initial stability, satisfactory subsequent bone ingrowth, smooth load transfer, and low-friction bearing surfaces.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Porosity , Prosthesis Design , Reoperation
SELECTION OF CITATIONS
SEARCH DETAIL
...