1.
Analyst ; 144(1): 68-86, 2018 Dec 17.
Article in English | MEDLINE | ID: mdl-30394455

ABSTRACT

Bacterial biofilms are among the oldest and most prevalent multicellular life forms on Earth and are increasingly relevant in research areas related to industrial fouling, medicine and biotechnology. The main hurdles to obtaining definitive experimental results include time-varying biofilm properties, structural and chemical heterogeneity, and especially their strong sensitivity to environmental cues. Therefore, in addition to judicious choice of measurement tools, a well-designed biofilm study requires strict control over experimental conditions, more so than most chemical studies. Due to excellent control over a host of physiochemical parameters, microfluidic flow cells have become indispensable in microbiological studies. Not surprisingly, the number of lab-on-chip studies focusing on biofilms and other microbiological systems with expanded analytical capabilities has expanded rapidly in the past decade. In this paper, we comprehensively review the current state of microfluidic bioanalytical research applied to bacterial biofilms and offer a perspective on new approaches that are expected to drive continued advances in this field.


Subject(s)
Biofilms , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/methods , Bacteria/metabolism , Electrochemical Techniques/methods , Microfluidic Analytical Techniques/instrumentation , Microscopy/methods , Spectrophotometry/methods , Spectrum Analysis, Raman/methods
2.
Anal Chem ; 90(24): 14475-14483, 2018 12 18.
Article in English | MEDLINE | ID: mdl-30449089

ABSTRACT

A fully automated linear scanning attenuated total reflection (ATR) accessory is presented for Fourier transform infrared (FTIR) spectroscopy. The approach is based on the accurate displacement of a multibounce ATR crystal relative to a stationary infrared beam. To ensure accurate positioning and to provide a second sample characterization mode, a custom-built microscope was integrated into the system and the computerized work flow. Custom software includes automated control and measurement routines with a straightforward user interface for selecting parameters and monitoring experimental progress. This cost-effective modular system can be implemented on any research-grade spectrometer with a standard sample compartment for new bioanalytical chemistry studies. The system was validated and optimized for use with microfluidic flow cells containing growing Pseudomonas sp. bacterial biofilms. The complementarity among the scan positioning accuracy, measurement spatial resolution, and the microchannel dimensions paves the way for parallel biological assays with real-time control over environmental parameters and minimal manual labor. By rotating the channel orientation relative to the beam path, the system could also be used for acquisition of linear biochemical maps and stitched microscope images along the channel length.


Subject(s)
Biofilms , Microscopy/methods , Pseudomonas/chemistry , Spectroscopy, Fourier Transform Infrared , Biofilms/growth & development , Microfluidics , Microscopy/instrumentation , Pseudomonas/physiology , Reproducibility of Results , Software
3.
Sensors (Basel) ; 16(12)2016 Nov 29.
Article in English | MEDLINE | ID: mdl-27916849

ABSTRACT

We build on the concept of hot intrusion embossing to develop a one-step fabrication method for thermoplastic microfluidic channels containing integrated three-dimensional features. This was accomplished with simple, rapid-to-fabricate imprint templates containing microcavities that locally control the intrusion of heated thermoplastic based on their cross-sectional geometries. The use of circular, rectangular and triangular cavity geometries was demonstrated for the purposes of forming posts, multi-focal length microlense arrays, walls, steps, tapered features and three-dimensional serpentine microchannels. Process variables, such as temperature and pressure, controlled feature dimensions without affecting the overall microchannel geometry. The approach was demonstrated for polycarbonate, cycloolefin copolymer and polystyrene, but in principle is applicable to any thermoplastic. The approach is a step forward towards rapid fabrication of complex, robust, microfluidic platforms with integrated multi-functional elements.

4.
Braz. j. pharm. sci ; 51(1): 213-219, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-751361

ABSTRACT

In the present work, acid dissociation constant (pKa) values of muscimol derivatives were calculated using the Density Functional Theory (DFT) method. In this regard, free energy values of neutral, protonated and deprotonated species of muscimol were calculated in water at the B3LYP/6-31G(d) basis sets. The hydrogen bond formation of all species had been analyzed using the Tomasi's method. It was revealed that the theoretically calculated pKa values were in a good agreement with the existing experimental pKa values, which were determined from capillary electrophoresis, potentiometric titration and UV-visible spectrophotometric measurements.


No presente trabalho, calculou-se a constante de dissociação do ácido (pKa) dos derivados de muscimol, utilizando-se o método da teoria do funcional de densidade (DFT). Com esse objetivo, calcularam-se os valores das espécies neutra, protonada e desprotonada do muscimol em água em base B3LYP/6-31G(d). A formação da ligação de hidrogênio de todas as espécies foi analisada utilizando o método de Tomasi. Demonstrou-se que os valores de pKa calculados teoricamente estavam em boa concordância com os valores experimentais disponíveis, determinados por eletroforese capilar, titulação potenciométrica e medidas por espectrofotometria UV-visível.


Subject(s)
Dissolution , Muscimol/analysis , Hydrogen Bonding