Am J Med ; 126(8): 709-17, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23764266

ABSTRACT

OBJECTIVE: The study objective was to determine how best to use high-sensitivity cardiac troponin T (hscTnT) to diagnose myocardial infarction. METHODS: A total of 358 patients presenting with acute coronary syndromes sampled at admission and 2, 4, and 6 to 8 hours. Both contemporary cardiac troponin T (cTnT) and hscTnT were measured. Patients were classified with conventional cTnT values by independent investigators. Myocardial infarction required a cTnT value ≥99th reference percentile and a ≥20% change. RESULTS: Seventy-nine patients had non-ST-segment elevation myocardial infarction, 105 patients had unstable angina, and 174 patients had nonacute coronary syndromes. A cTnT cutoff at the 10% coefficient of variation value missed 14.5% of infarctions. hscTnT had a sensitivity at admission of 89.9%, but specificity was only 75.1% because of elevations in 45.3% and 25.3% of those with unstable angina and nonacute coronary syndromes, respectively. The optimal value for myocardial infarction diagnosis with hscTnT was 25 ng/L at admission and 30 ng/L during serial sampling. All infarctions were diagnosed within 4 hours, with a time saving of 11 and 68 minutes compared with a cTnT value at the 99th reference percentile value and a cTnT value at a coefficient of variation of 10%. By using the 99th percentile of hsTnT plus a ≥20% change, 25 additional infarctions were identified. With these included, the optimal cutoff decreased to 12 ng/L at admission and 13 ng/L over time, but time to diagnosis increased. CONCLUSIONS: The gold standard used to diagnose myocardial infarction makes a major difference in the results. When myocardial infarction is diagnosed using hscTnT 99th percentile values with a 20% change, more are identified, diagnosis is delayed, and the optimal value for use is reduced.


Subject(s)
Acute Coronary Syndrome/blood , Myocardial Infarction/blood , Troponin T/blood , Acute Coronary Syndrome/diagnosis , Adult , Aged , Aged, 80 and over , Angina, Unstable/blood , Angina, Unstable/diagnosis , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnosis , Prospective Studies , Reference Values , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...