Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Chir Gynaecol ; 90(4): 286-9, 2001.
Article in English | MEDLINE | ID: mdl-11820418

ABSTRACT

BACKGROUND AND AIMS: The Marshall-Marchetti-Krantz procedure (MMK) is a vesico-urethral suspension, for the correction of urethral hypermobility in women with stress urinary incontinence. This study aims to describe the long-term outcome of the procedure. MATERIAL AND METHODS: 40 women with stress incontinence underwent the MMK. All operations were performed by one surgeon. Analysis of patients' notes yielded the early continence rate and perioperative morbidity. Long-term outcome was measured by means of a postal questionnaire with telephone contact to ensure maximum uptake. RESULTS: The immediate continence rate was 82%. Continence rates at up to 22 years follow-up (mean 8.5 years) is 61%. All failures occurred within 2 years of the operation. CONCLUSION: Patients still continent two years after the MMK will maintain continence in the long-term.


Subject(s)
Urethra/surgery , Urinary Bladder/surgery , Urinary Incontinence, Stress/surgery , Urologic Surgical Procedures , Adult , Aged , Female , Humans , Middle Aged , Treatment Outcome , Urologic Surgical Procedures/adverse effects
2.
Science ; 186(4160): 234-9, 1974 Oct 18.
Article in English | MEDLINE | ID: mdl-4414930

ABSTRACT

Diffraction patterns that are highly reproducible, of useful quality, and consistent with the input generating them can be easily obtained with a microscope system. The input can be either a reduced photograph or a thin section. With two exceptions, the relationships between a thin section and its diffraction pattern produced by a petrographic microscope are the same as the relationships between a photographic input and its diffraction pattern produced by a conventional ODA system. The exceptions are that the diffraction patterns generated directly by the thin sections may be asymmetrical or, if the thin section is sufficiently heterogeneous, may be smeared. The microscope system is generally more useful than a conventional ODA system for the analysis of microfabric in thin sections. One can readily use the microscope system to analyze elements of widely varying spatial frequency simply by changing the objectives. The diffraction patterns can be magnified by changing to a higherpower ocular. In most cases the microscope-generated diffraction pattern transmits the useful spatial information in the thin section more completely than the conventionally produced diffraction pattern; the photographic inputs for the conventionally produced diffraction pattern emphasize lower-frequency spatial information. This property, combined with the microscope system's better response to twinning, makes the microscope more sensitive to commonly used microfabric elements. For the analysis of thin sections, a conventional ODA system is superior to the microscope system in only three cases. First, if one wants to analyze the entire thin section at one time, a conventional system must be used with a photographic input of the thin section. Second, if the thin section is extremely heterogeneous (crystallographically or mineralogically), the microscope-generated diffraction pattern may exhibit gross smearing even with the highestpower objectives available. Finally, the thin section may contain only elements of low spatial frequency that will not generate diffraction dots far enough radially from the central spot to be resolvable. More study will be needed to establish the precision of spatial frequency measurements from diffraction patterns generated directly by thin sections with the microscope system. Experiments with a variety of film types and sources of illumination will, in all likelihood, lead to a reduction in the exposure times used to record diffraction patterns with the microscope (9). A complete ODA system must have directional and frequency-filtering capabilities. In order to establish these capabilities for the microscope system, components will need to be designed and fabricated and the microscope body may have to be modified. The possibility of applying the microscope technique in reflected light on a real-time basis should be investigated. This would be a valuable tool in the quantitative analysis of microfracture initiation and propagation and the analysis of overall fabric changes during experimental deformation of rock both in situ and in the laboratory. The technique presented here can be used with a less expensive microscope, if it has a focusable Bertrand lens. Our experiments with relatively inexpensive microscopes indicated that the only major problem is alignment of the illuminating system (light-filter-condenser).


Subject(s)
Microscopy/methods , Optics and Photonics/methods , Fourier Analysis , Microscopy/instrumentation , Microtomy , Optics and Photonics/instrumentation , Photomicrography
SELECTION OF CITATIONS
SEARCH DETAIL
...