Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Athl Train ; 2020 Jun 18.
Article in English | MEDLINE | ID: mdl-34129675

ABSTRACT

CONTEXT: State laws provide general guidelines for sport-related concussion (SRC) management, but do not comprehensively address the multiple layers of management for this complex injury. While high schools are encouraged to develop a SRC protocol that includes both state law tenets and additional management practices, the execution of this warrants examination. OBJECTIVE: To investigate state law compliance and practice components included in high school SRC protocols, and determine whether the degree of sports medicine coverage influenced protocol quality. DESIGN: Qualitative document analysis. SETTING: High school athletics. PARTICIPANTS: In total, 184 Pennsylvania high schools [24.3% of schools statewide; full-time athletic trainer=149, part-time athletic trainer=13, missing=21] voluntarily provided copies of their protocol from the 2018-2019 academic year. MAIN OUTCOME MEASURES: Four athletic trainers conducted document analyses using a 67-item component analysis guide. Frequencies were computed for included protocol components related to the state law, preparticipation and prevention, recognition and assessment, and management. The difference in the total number of included components (max 60) by sports medicine coverage was assessed using a Mann-Whitney U test. RESULTS: There was heterogeneity in components included in the submitted protocols. Only 23.4% included all mandatory state law tenets. Immediate removal from play was noted in 67.4% of protocols, while only 1.6% contained prevention strategies. Return-to-play was addressed more frequently than return-to-learn (74.5% versus 32.6%). The sample had a mean of 15.5±9.7 total components per protocol. Schools with full-time sports medicine coverage had significantly more protocol components than those with part-time athletic trainers (15 [8.5-22.5] versus 6 [3-10.5] median components; U = 377.5, p < .001) Conclusions: School-level written SRC protocols were often missing components of the state law and additional best practice recommendations. Full-time sports medicine coverage in high schools is recommended to increase SRC protocol and healthcare quality.

2.
J Pediatr ; 181: 248-253.e3, 2017 02.
Article in English | MEDLINE | ID: mdl-27866821

ABSTRACT

OBJECTIVE: To evaluate a novel technique designed to reduce the negative impact of motion artifacts in infant dual-energy X-ray absorptiometry (DXA) scans. STUDY DESIGN: Using cross-sectional data from a large multicenter study, we developed and tested advanced methods for infant scan analysis. Newborns (n = 750) received spine and whole-body DXA scans with up to 3 attempts to acquire a motion free scan. Precision of infant DXA was estimated from visits with multiple valid scans. Accuracy of regional reflection, fusion, and omission techniques was estimated by comparing modified scans to unmodified valid scans. The effectiveness of the acquisition and analysis protocol was represented by the reduction in rate of failure to acquire valid results from infant visits. RESULTS: For infant whole-body DXA, arm reflection and all fusion techniques caused no significant changes to bone mineral content, bone mineral density, bone area, total mass, fat mass, lean mass, and percentage fat. Leg reflection and arm/leg dual-reflection caused significant changes to total mass, but the percentage change remained small. For infant spine DXA, fusion and omission caused no significant changes. Advanced analysis techniques reduced the failure rate of whole-body scanning from 20.8% to 9.3% and the failure rate of spine scanning from 8.9% to 2.4%. CONCLUSIONS: Advanced analysis techniques significantly reduced the impact of motion artifacts on infant DXA scans. We suggest this protocol be used in future infant DXA research and clinical practice.


Subject(s)
Absorptiometry, Photon/methods , Body Composition , Bone Density , Bone and Bones/metabolism , Cross-Sectional Studies , Humans , Infant , Infant, Newborn , Reproducibility of Results
3.
J Clin Densitom ; 18(1): 76-85, 2015.
Article in English | MEDLINE | ID: mdl-24200863

ABSTRACT

Few studies have described the long-term repeatability of dual-energy X-ray absorptiometry scans. Even fewer studies have been performed with enough participants to identify possible precision covariates such as sex, age, and body mass index (BMI). Our objective was to investigate the long-term repeatability of both total and subregional body composition measurements and their associations with covariates in a large sample. Two valid whole-body dual-energy X-ray absorptiometry scans were available for 609 participants in the National Health and Nutrition Examination Survey 2000-2002. Participants with scan-quality issues were excluded. Participants varied in race and ethnicity, sex, age (mean 38.8±17.5; range 16-69 yr), and BMI (mean, 26.9±5.2; range 14.1-43.5 kg/m2). The length of time between scans ranged from 3 to 51 days (mean, 18.7±8.4). Precision error estimates for total body measures (bone mineral density, bone mineral content, lean mass, total mass, fat mass, and percent body fat) were calculated as root mean square percent coefficients of variation and standard deviations. The average root mean square percent coefficients of variation and root mean square standard deviations of the precision error for total body variables were 1.12 and 0.01 g/cm2 for bone mineral density, 1.14 and 27.3 g for bone mineral content, 1.97 and 505 g for fat mass, 1.46 and 760 g for lean mass, 1.10 and 858 g for total mass, and 1.80 and 0.59 for percent body fat. In general, only fat and lean masses were impacted by participant and scan qualities (obesity category, sex, the magnitude of the body composition variables, and time between scans). We conclude that long-term precision error values are impacted by BMI, and sex. Our long-term precision error estimates may be more suitable than short-term precision for calculating least significant change and monitoring time intervals.


Subject(s)
Body Composition , Bone Density , Absorptiometry, Photon/methods , Adult , Analysis of Variance , Body Mass Index , Ethnicity , Female , Humans , Male , Middle Aged , Nutrition Surveys , Time , United States
4.
Am J Clin Nutr ; 95(1): 25-31, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22134952

ABSTRACT

BACKGROUND: Total body volume (TBV), with the exclusion of internal air voids, is necessary to quantify body composition in Lohman's 4-compartment (4C) model. OBJECTIVE: This investigation sought to derive a novel, TBV measure with the use of only dual-energy X-ray absorptiometry (DXA) attenuation values for use in Lohman's 4C body composition model. DESIGN: Pixel-specific masses and volumes were calculated from low- and high-energy attenuation values with the use of first principle conversions of mass attenuation coefficients. Pixel masses and volumes were summed to derive body mass and total body volume. As proof of concept, 11 participants were recruited to have 4C measures taken: DXA, air-displacement plethysmography (ADP), and total body water (TBW). TBV measures with the use of only DXA (DXA-volume) and ADP-volume measures were compared for each participant. To see how body composition estimates were affected by these 2 methods, we used Lohman's 4C model to quantify percentage fat measures for each participant and compared them with conventional DXA measures. RESULTS: DXA-volume and ADP-volume measures were highly correlated (R(2) = 0.99) and showed no statistically significant bias. Percentage fat by DXA volume was highly correlated with ADP-volume percentage fat measures and DXA software-reported percentage fat measures (R(2) = 0.96 and R(2) = 0.98, respectively) but were slightly biased. CONCLUSIONS: A novel method to calculate TBV with the use of a clinical DXA system was developed, compared against ADP as proof of principle, and used in Lohman's 4C body composition model. The DXA-volume approach eliminates many of the inherent inaccuracies associated with displacement measures for volume and, if validated in larger groups of participants, would simplify the acquisition of 4C body composition to a single DXA scan and TBW measure.


Subject(s)
Absorptiometry, Photon/methods , Adipose Tissue/diagnostic imaging , Body Composition , Body Size , Obesity/diagnostic imaging , Plethysmography/methods , Adult , Female , Humans , Male , Middle Aged , Models, Biological , Obesity/diagnosis , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...