Circ Arrhythm Electrophysiol ; 17(6): e012635, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38804141

ABSTRACT

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% (P<0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P=0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P=0.004, and odds ratio, 29.93; P<0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


Subject(s)
Catheter Ablation , Echocardiography , Saline Solution , Steam , Tachycardia, Ventricular , Therapeutic Irrigation , Humans , Male , Female , Saline Solution/administration & dosage , Middle Aged , Catheter Ablation/adverse effects , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnostic imaging , Aged , Embolism, Air/prevention & control , Embolism, Air/etiology , Embolism, Air/diagnostic imaging , Treatment Outcome , Risk Factors , Predictive Value of Tests , Electric Impedance
2.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38367008

ABSTRACT

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Tachycardia, Ventricular , Male , Humans , Middle Aged , Female , Saline Solution/adverse effects , Steam , Prospective Studies , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Tachycardia, Ventricular/surgery , Therapeutic Irrigation/adverse effects
3.
JACC Clin Electrophysiol ; 10(2): 193-202, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38069975

ABSTRACT

BACKGROUND: Risks of radiofrequency catheter ablation for ventricular arrhythmias include emboli and bleeding complications but data on antithrombotic regimens are limited and guidelines do not specify a systematic approach. OBJECTIVES: This study sought to assess embolic and bleeding complications in relation to pre-periprocedure and post-periprocedure antithrombotic regimens. METHODS: Prospective assessment for complications was performed for 663 endocardial radiofrequency catheter ablation procedures in 616 consecutive patients (median age 64 years [Q1-Q3: 54-73 years], 70.3% men, 71.6% with cardiomyopathy, 44.5% with sustained ventricular tachycardia). RESULTS: There were 2 strokes (0.3%; 95% CI: 0.0%-0.8%), 1 transient ischemic attack (0.15%), and 2 pulmonary emboli (0.3%). There were 39 bleeding complications (5.9%) including 11 pericardial effusions (1.7%), and 28 related to vascular access (4.2%). Consistent with the prevalence of coronary artery disease (47.5%), atrial fibrillation (30.0%), and prior stroke (10.6%), preprocedure, 464 patients (70.0%) were taking antithrombotic agents including 220 (33.2%) taking aspirin alone (ASA), and 163 (24.6%) taking warfarin or a direct acting oral anticoagulant (DOAC). Preprocedure non-ASA antiplatelet use (OR: 2.846; P = 0.011) and DOAC use (OR: 2.585; P = 0.032) were associated with risk of bleeding complications. Following ablation, 49.8% of patients were treated with ASA 325 mg/d and 30.3% received DOACs or warfarin. New DOAC or warfarin administration was initiated in only 6.6% of patients. Overall, 39.7% of patients continued the same preprocedure antithrombotic regimen. CONCLUSIONS: Stroke is a rare complication of radiofrequency catheter ablation for ventricular arrhythmia using ASA 325 mg/d as a minimal postprocedure regimen with more potent regimens for selected patients.


Subject(s)
Atrial Fibrillation , Stroke , Male , Humans , Middle Aged , Female , Warfarin/adverse effects , Anticoagulants/adverse effects , Hemorrhage/etiology , Hemorrhage/chemically induced , Fibrinolytic Agents , Prospective Studies , Stroke/etiology , Stroke/epidemiology , Atrial Fibrillation/surgery , Aspirin/adverse effects
4.
J Cardiovasc Electrophysiol ; 34(11): 2403-2405, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37787011

ABSTRACT

INTRODUCTION: Intracardiac echocardiography (ICE) reveals mobile thrombus on implantable electronic device leads in some patients undergoing electrophysiologic procedures. METHODS: ICE was performed in a patient undergoing ventricular tachycardia (VT) ablation. RESULTS: ICE showed extensive mobile thrombi on the implantable cardioverter defibrillator lead. Radiofrequency catheter ablation of VT from perimitral scar was safely performed via a retrograde aortic approach. After the procedure, chronic anticoagulation was initiated. CT-angiography of the chest 2 months later showed no pulmonary emboli. CONCLUSIONS: The significance of these thrombi, as related to chronic pulmonary embolization, warrants further study.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Thrombosis , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Wind , Heart Diseases/surgery , Thrombosis/diagnostic imaging , Thrombosis/etiology , Catheter Ablation/methods , Hair , Treatment Outcome
9.
Proc (Bayl Univ Med Cent) ; 34(4): 530-531, 2021 Mar 05.
Article in English | MEDLINE | ID: mdl-34219949

ABSTRACT

Abdominal pregnancy is a rare form of ectopic pregnancy with high morbidity and mortality. There are a limited number of case reports of abdominal ectopic pregnancies. We present a case of a 29-year-old woman who presented to her obstetrician at 17 weeks' gestation with abdominal pain. A sonogram and confirmatory magnetic resonance imaging demonstrated an abdominal ectopic pregnancy. The patient underwent exploratory laparotomy with removal of the ectopic pregnancy. Our case presents an opportunity to discuss a rare form of ectopic pregnancy and the importance of proper diagnosis and treatment to reduce morbidity and mortality.

13.
MMWR Morb Mortal Wkly Rep ; 69(19): 599-602, 2020 May 15.
Article in English | MEDLINE | ID: mdl-32407299

ABSTRACT

The threat of introduction of coronavirus disease 2019 (COVID-19) into the United States with the potential for community transmission prompted U.S. federal officials in February 2020 to screen travelers from China, and later Iran, and collect and transmit their demographic and contact information to states for follow-up. During February 5-March 17, 2020, the California Department of Public Health (CDPH) received and transmitted contact information for 11,574 international travelers to 51 of 61 local health jurisdictions at a cost of 1,694 hours of CDPH personnel time. If resources permitted, local health jurisdictions contacted travelers, interviewed them, and oversaw 14 days of quarantine, self-monitoring, or both, based on CDC risk assessment criteria for COVID-19. Challenges encountered during follow-up included errors in the recording of contact information and variation in the availability of resources in local health jurisdictions to address the substantial workload. Among COVID-19 patients reported to CDPH, three matched persons previously reported as travelers to CDPH. Despite intensive effort, the traveler screening system did not effectively prevent introduction of COVID-19 into California. Effectiveness of COVID-19 screening and monitoring in travelers to California was limited by incomplete traveler information received by federal officials and transmitted to states, the number of travelers needing follow-up, and the potential for presymptomatic and asymptomatic transmission. More efficient methods of collecting and transmitting passenger data, including electronic provision of flight manifests by airlines to federal officials and flexible text-messaging tools, would help local health jurisdictions reach out to all at-risk travelers quickly, thereby facilitating timely testing, case identification, and contact investigations. State and local health departments should weigh the resources needed to implement incoming traveler monitoring against community mitigation activities, understanding that the priorities of each might shift during the COVID-19 pandemic.


Subject(s)
Coronavirus Infections/epidemiology , Coronavirus Infections/prevention & control , Disease Outbreaks , Pandemics/prevention & control , Pneumonia, Viral/epidemiology , Pneumonia, Viral/prevention & control , Public Health Surveillance , COVID-19 , California/epidemiology , Humans , Internationality , Travel
15.
IEEE Trans Biomed Eng ; 52(5): 859-68, 2005 May.
Article in English | MEDLINE | ID: mdl-15887535

ABSTRACT

In this paper, the effects of visual feedback and aging on postural sway systems and signals are investigated by analyzing the transient phase difference between "input" and "output" which correspond to center of pressure (COP) and center of mass (COM), respectively. In order to analyze the transient phase difference characteristics of COP and COM, a relatively new cross time-frequency analysis technique that provides time- and frequency-localized phase difference information is utilized. The feedback control process in the postural sway is interpreted in terms of a feedback compensator which is characterized in terms of a phase difference. Using the experimental results of the transient phase difference obtained from the cross time-frequency distribution, it is demonstrated that the postural control of young persons are more stable and rely more on visual sensory feedback to stabilize postural control compared to that of the elderly persons.


Subject(s)
Aging/physiology , Diagnosis, Computer-Assisted/methods , Models, Neurological , Movement/physiology , Postural Balance/physiology , Posture/physiology , Vision, Ocular/physiology , Adaptation, Physiological/physiology , Adult , Aged , Algorithms , Computer Simulation , Feedback/physiology , Humans , Motor Activity/physiology , Regression Analysis , Statistics as Topic