Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 62(20): 7938-7958, 2017 Oct 03.
Article in English | MEDLINE | ID: mdl-28858854

ABSTRACT

Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson's correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r > 0.87 and p-values >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed model are compatible with the observed clinical outcome. The extension of the photon iso-effective dose model has allowed, for the first time, the determination of the photon iso-effective dose for unacceptable complications in the dose-limiting normal tissue. Finally, the formalism developed in this work to compute photon-equivalent doses can be applied to other therapies that combine mixed radiation fields, such as hadron therapy.


Subject(s)
Boron Neutron Capture Therapy , Disease Models, Animal , Head and Neck Neoplasms/radiotherapy , Melanoma/radiotherapy , Mouth Neoplasms/radiotherapy , Mucositis/radiotherapy , Photons , Animals , Carcinoma, Squamous Cell/radiotherapy , Cricetinae , Humans , Precancerous Conditions/radiotherapy , Radiometry
2.
Med Phys ; 42(7): 4161-73, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26133616

ABSTRACT

PURPOSE: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (l)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. METHODS: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. RESULTS: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect quantification of the estimated value in the explanted healthy lung. The proposed preclinical animal model allowed for the study of the explanted lung. As expected, the boron concentration values fell as a result of the application of the preservation protocol required to preserve the lung function. The distribution of the boron concentration retention factor was obtained for healthy lung, with a mean value of 0.46 ± 0.14 consistent with that reported for metastatic colon carcinoma model in rat perfused lung. Considering the human lung model and suitable tumor control probability for lung cancer, a promising average fraction of controlled lesions higher than 85% was obtained even for a low tumor-to-normal boron concentration ratio of 2. CONCLUSIONS: This work reports for the first time data supporting the validity of the ovine model as an adequate human surrogate in terms of boron kinetics and uptake in clinically relevant tissues. Collectively, the results and analysis presented would strongly suggest that ex situ whole lung BNCT irradiation is a feasible and highly promising technique that could greatly contribute to the treatment of metastatic lung disease in those patients without extrapulmonary spread, increasing not only the expected overall survival but also the resulting quality of life.


Subject(s)
Boron Neutron Capture Therapy/methods , Lung Neoplasms/radiotherapy , Animals , Argentina , Boron/pharmacokinetics , Boron/therapeutic use , Boron Compounds/pharmacokinetics , Boron Neutron Capture Therapy/instrumentation , Feasibility Studies , Fructose/analogs & derivatives , Fructose/pharmacokinetics , Humans , Lung/metabolism , Lung/radiation effects , Lung Neoplasms/metabolism , Models, Animal , Models, Biological , Photons , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Sheep , Time Factors , Tissue Distribution
3.
Appl Radiat Isot ; 88: 50-4, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24447934

ABSTRACT

A model of multiple lung metastases in BDIX rats is under study at CNEA (Argentina) to evaluate the feasibility of BNCT for multiple, non-surgically resectable lung metastases. A practical shielding device that comfortably houses a rat, allowing delivery of a therapeutic, uniform dose in lungs while protecting the body from the neutron beam is presented. Based on the final design obtained by numerical simulations, the shield was constructed, experimentally characterized and recently used in the first in vivo experiment at RA-3.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Lung Neoplasms/radiotherapy , Lung Neoplasms/secondary , Radiation Protection/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Animals , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Radiotherapy Dosage , Rats
4.
Appl Radiat Isot ; 88: 94-8, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24360862

ABSTRACT

BNCT was proposed for the treatment of diffuse, non-resectable tumors in the lung. We performed boron biodistribution studies with 5 administration protocols employing the boron carriers BPA and/or GB-10 in an experimental model of disseminated lung metastases in rats. All 5 protocols were non-toxic and showed preferential tumor boron uptake versus lung. Absolute tumor boron concentration values were therapeutically useful (25-76ppm) for 3 protocols. Dosimetric calculations indicate that BNCT at RA-3 would be potentially therapeutic without exceeding radiotolerance in the lung.


Subject(s)
Boron Compounds/administration & dosage , Boron Compounds/pharmacokinetics , Boron Neutron Capture Therapy/methods , Lung Neoplasms/metabolism , Lung Neoplasms/secondary , Phenylalanine/analogs & derivatives , Animals , Cell Line, Tumor , Drug Combinations , Lung Neoplasms/radiotherapy , Metabolic Clearance Rate , Organ Specificity , Phenylalanine/administration & dosage , Phenylalanine/pharmacokinetics , Radiotherapy Dosage , Rats , Tissue Distribution
5.
Oral Dis ; 19(8): 789-95, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23410091

ABSTRACT

OBJECTIVES: Field-cancerized tissue can give rise to second primary tumours, causing therapeutic failure. Boron neutron capture therapy (BNCT) is based on biological targeting and would serve to treat undetectable foci of malignant transformation. The aim of this study was to optimize BNCT for the integral treatment for oral cancer, with particular emphasis on the inhibitory effect on tumour development originating in precancerous conditions, and radiotoxicity of different BNCT protocols in a hamster cheek pouch oral precancer model. MATERIALS AND METHODS: Groups of cancerized hamsters were locally exposed to single or double (2 or 4 weeks apart) applications of BNCT at different dose levels, mediated by the boron compounds boronophenylalanine (BPA) or BPA and decahydrodecaborate (GB-10) administered jointly. Cancerized, sham-irradiated hamsters served as controls. Clinical status, tumour development from field-cancerized tissue and mucositis were followed for 8 months. RESULTS: A double application (4 weeks apart) of BNCT mediated by GB-10+ BPA at a total dose of 10 Gy in two 5-Gy doses rendered the best therapeutic advantage (63-100% inhibition of tumour development from field-cancerized tissue), minimizing dose-limiting mucositis. CONCLUSION: BNCT can be optimized for the integral treatment for head and neck cancer, considering the implications for field-cancerized tissue.


Subject(s)
Boron Neutron Capture Therapy , Mouth Neoplasms/radiotherapy , Precancerous Conditions/radiotherapy , Animals , Cricetinae , Disease Models, Animal
6.
Appl Radiat Isot ; 69(12): 1924-7, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21478026

ABSTRACT

A facility for the irradiation of a section of patients' explanted liver and lung was constructed at RA-3 reactor, Comisión Nacional de Energía Atómica, Argentina. The facility, located in the thermal column, is characterized by the possibility to insert and extract samples without the need to shutdown the reactor. In order to reach the best levels of security and efficacy of the treatment, it is necessary to perform an accurate dosimetry. The possibility to simulate neutron flux and absorbed dose in the explanted organs, together with the experimental dosimetry, allows setting more precise and effective treatment plans. To this end, a computational model of the entire reactor was set-up, and the simulations were validated with the experimental measurements performed in the facility.

SELECTION OF CITATIONS
SEARCH DETAIL
...