Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Lab Chip ; 22(16): 3045-3054, 2022 08 09.
Article in English | MEDLINE | ID: mdl-35833547

ABSTRACT

Thread-based microfluidic analytical devices have received growing attention since threads have some advantages over other materials. Compared to paper, threads are also capable of spontaneously transporting fluid due to capillary action, but they have superior mechanical strength and do not require hydrophobic barriers. Therefore, thread-based microfluidic devices can be inexpensively fabricated with no need for external pumps or sophisticated microfabrication apparatus. Despite these outstanding features, achieving a controlled and continuous flow rate is still a challenging task, mainly due to fluid evaporation. Here, we overcome this challenge by inserting a cotton thread into a polyethylene tube aiming to minimize fluid evaporation. Also, a cotton piece was inserted into the outlet reservoir to improve the wicking ability of the device. This strategy enabled the fabrication of an innovative electrochemical thread in a tubing microfluidic device that was capable to hold a consistent flow rate (0.38 µL s-1) for prolonged periods, allowing up to 100 injections in a single device by simply replacing the cotton piece in the outlet reservoir. The proposed device displayed satisfactory analytical performance for selected model analytes (dopamine, hydrogen peroxide, and tert-butylhydroquinone), in addition to being successfully used for quantification of nitrite in spiked artificial saliva samples. Beyond the flow rate improvement, this "thread-in-tube" strategy ensured the protection of the fluid from external contamination while making it easier to connect the electrode array to the microchannels. Thus, we envision that the thread in a tube strategy could bring interesting improvements to thread-based microfluidic analytical devices.


Subject(s)
Lab-On-A-Chip Devices , Microfluidic Analytical Techniques , Electrodes , Hydrogen Peroxide , Textiles
2.
Anal Chim Acta ; 1143: 53-64, 2021 Jan 25.
Article in English | MEDLINE | ID: mdl-33384130

ABSTRACT

Lactose (LAC) is a disaccharide - major sugar, present in milk and dairy products. LAC content is an important indicator of milk quality and abnormalities in food industries, as well as in human and animal health. The present study reports the development of an innovative imprinted voltammetric sensor for sensitive detection of LAC. The sensor was constructed using electropolymerized pyrrole (Py) molecularly imprinted polymer (MIP) on graphite paper electrode (PE). The MIP film was constructed through the electrosynthesis of polypyrrole (PPy) in the presence of LAC (template molecule) on PE (PPy/PE). To optimize the detection conditions, several factors affecting the PPy/PE sensor performance were assessed by multivariate methods (Plackett-Burman design and central composite design). Under optimized conditions, the proposed analytical method was applied for LAC detection in whole and LAC-free milks, where it demonstrated high sensitivity and selectivity, with two dynamic linear ranges of concentration (1.0-10 nmol L-1 and 25-125 nmol L-1) and a detection limit of 0.88 nmol L-1. The MIP sensor showed selective molecular recognition for LAC in the presence of structurally related molecules. The proposed PPy/PE sensor exhibited good stability, as well as excellent reproducibility and repeatability. Based on the results obtained, the PPy/PE is found to be highly promising for sensitive detection of LAC.


Subject(s)
Graphite , Molecular Imprinting , Animals , Electrochemical Techniques , Electrodes , Humans , Lactose , Limit of Detection , Polymers , Pyrroles , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...