Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Sep Sci ; 44(11): 2234-2249, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33813799

ABSTRACT

Per- and polyfluorinated alkyl substances are large class of man-made compounds known in the media as "forever chemicals". In 2015, ASTM International published ASTM D7979, for the analysis of per- and polyfluorinated alkyl substances in non-potable water samples. This method extracts the substances by co-solvation with methanol and measures targeted compounds using liquid chromatography-tandem mass spectrometry. ASTM D7979 is a performance-based method that analyzes 31 compounds plus 14 isotopically labeled surrogates. The minimum reporting limit is approximately 10 ng/L with an analytical range of 10-200 ng/L for most compounds. Expected recovery of surrogates and spiked matrices is 70-130%. Samples containing high suspended solids can be analyzed with minimal interferences and potential loss of analyte. The method is consistent with ASTM and EPA's sustainable development goals by using reduced volumes of sample, solvent, and minimizing hazardous solvents and sample preparation materials while maintaining data quality and detection limits that are suitable for the intended use. This paper covers the rationale, outlines some of the challenges associated with analysis of per- and polyfluorinated alkyl substances, and describes the steps taken by the ASTM Committee D19 task group to develop, optimize, and validate this method.

2.
J Minim Access Surg ; 12(2): 170-2, 2016.
Article in English | MEDLINE | ID: mdl-27073312

ABSTRACT

Acute appendicitis is one of the commonest surgical emergencies worldwide. There is considerable variation in prevalence of appendicoliths with appendicitis. Most of the patients with appendicoliths are asymptomatic and they are not pathognomic for acute appendicitis. However, appendicoliths show increased association with perforation and abscess formation. Appendicolith are quite common, being present in 3% of general population and in nearly 10% cases of appendicitis. However, giant appendicoliths measuring over 2 centimeters (cms) are extremely rare. Computed Tomography (CT) has increased their pre-operative diagnosis considerably. Use of spectral analysis can give us the details of composition of the stone pre-operatively. We present a young male diagnosed pre-operatively on Non-Contrast Computed Tomography (NCCT) to have a giant calcium struvite appendicolith. On laparoscopy he had a 3 cm stone and an incidental Meckel's diverticulum and underwent appendectomy. The case is presented for the unique size of the appendicolith alongwith review of literature.

3.
Asian J Psychiatr ; 3(3): 157, 2010 Sep.
Article in English | MEDLINE | ID: mdl-23051577
4.
Environ Sci Technol ; 39(13): 4996-5004, 2005 Jul 01.
Article in English | MEDLINE | ID: mdl-16053102

ABSTRACT

Method 527 was developed to address the occurrence monitoring needs of the U.S. Environmental Protection Agency (EPA) under its second unregulated contaminant monitoring rule (UCMR 2). This method includes a wide range of semivolatile organic contaminants, including pesticides that were deferred during the first UCMR, flame retardants, and pyrethroid pesticides. This paper discusses the rationale for selection and inclusion of the various contaminants included in Method 527 and describes the challenges associated with developing analytical methods that will be used for the occurrence monitoring of such a diverse group of organic molecules. Method 527 employs solid-phase extraction with analysis by gas chromatography/ mass spectrometry (GC/MS). The final method preservation scheme requires the storage of samples in amber bottles buffered at pH 3.8 using citric acid to prevent degradation from acid-catalyzed hydrolysis and from UV light. Citric acid is also an effective antimicrobial reagent, preventing this mode of loss during storage. Ethylenediaminetetraacetic acid (EDTA) is added to remove transition metals such as copper, which was determined to degrade target analytes upon storage. Finally, free available chlorine (FAC), which is present in many finished waters and found to degrade a number of the targets, is removed using ascorbic acid. The final method meets all of the EPA UCMR survey requirements for sample storage, precision, accuracy, and sensitivity and will be proposed for use under the UCMR 2.


Subject(s)
Environmental Pollutants/analysis , Flame Retardants/analysis , Pesticides/analysis , Data Collection , Environmental Monitoring/methods , Hydrogen-Ion Concentration , United States , United States Environmental Protection Agency
SELECTION OF CITATIONS
SEARCH DETAIL
...