Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Cardiothorac Surg ; 52(4): 760-767, 2017 Oct 01.
Article in English | MEDLINE | ID: mdl-29156022

ABSTRACT

OBJECTIVES: Meta-analyses from observational and randomized studies have demonstrated benefits of off-pump surgery for hard and surrogate endpoints. In some of them, increased re-revascularization was noted in the off-pump groups, which could impact their long-term survival. Therefore, we analyzed the course of all patients undergoing isolated coronary surgery regarding the major cardiac and cerebrovascular event (MACCE) criteria. METHODS: A prospective register was taken from a high-volume off-pump center recording all anaortic off-pump (ANA), clampless off-pump (PAS-Port) and conventional (CONV) coronary artery bypass operations between July 2009 and June 2015. Propensity Score Matching was performed based on 28 preoperative risk variables. RESULTS: We identified 935 triplets (N = 2805). Compared with CONV, in-hospital mortality of both the ANA group (OR for ANA [95% CI] 0.25 [0.06; 0.83], P = 0.021), and the PAS-Port group was lower (OR for PAS-Port [95% CI] 0.50 [0.17; 1.32], P = 0.17). In the mid-term follow-up there were no significant differences between the groups regarding mortality (HR for ANA [95%-CI] 0.83 [0.55-1.26], P = 0.38; HR for PAS-Port [95%-CI] 1.06 [0.70-1.59], P = 0.79), incidence of stroke (HR for ANA 0.81 [0.43-1.53], P = 0.52; HR for PAS-Port 0.78 [0.41-1.50], P = 0.46), myocardial infarction (HR for ANA 0.53 [0.22-1.31], P = 0.17; HR for PAS-Port 0.78 [0.37-1.66], P = 0.52) or re-revascularization rate (HR for ANA 0.99 [0.67-1.44], P = 0.94; HR for PAS-Port 0.95 [0.65-1.38], P = 0.77). CONCLUSIONS: Both off-pump clampless techniques were associated with lower in-hospital mortality compared with conventional CABG. The mid-term course showed no difference with regard to the MACCE criteria between anaortic off-pump, clampless off-pump using PAS-Port and conventional CABG.


Subject(s)
Coronary Artery Bypass, Off-Pump/instrumentation , Coronary Artery Bypass/instrumentation , Coronary Artery Disease/surgery , Postoperative Complications/epidemiology , Propensity Score , Registries , Aged , Coronary Artery Disease/mortality , Follow-Up Studies , Germany/epidemiology , Hospital Mortality/trends , Humans , Incidence , Middle Aged , Prospective Studies , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...