1.
Opt Express ; 30(15): 26027-26042, 2022 Jul 18.
Article in English | MEDLINE | ID: mdl-36236801

ABSTRACT

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh's criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

2.
Appl Opt ; 61(23): 6811-6818, 2022 Aug 10.
Article in English | MEDLINE | ID: mdl-36255769

ABSTRACT

Scanning of lightweight circular diffractive optics, separate from central stops and apertures, is emerging as an approach to exploit advances in synchrotron x-ray sources. We consider the effects in a scanning microscope of offsets between the optic and its central stop and find that scan ranges of up to about half the diameter of the optic are possible with only about a 10% increase in the focal spot width. For large scanning ranges, we present criteria for the working distance between the last aperture and the specimen to be imaged.


Subject(s)
Microscopy , Optics and Photonics , X-Rays
3.
J Synchrotron Radiat ; 28(Pt 1): 309-317, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33399582

ABSTRACT

Ptychography is a rapidly developing scanning microscopy which is able to view the internal structures of samples at a high resolution beyond the illumination size. The achieved spatial resolution is theoretically dose-limited. A broadband source can provide much higher flux compared with a monochromatic source; however, it conflicts with the necessary coherence requirements of this coherent diffraction imaging technique. In this paper, a multi-wavelength reconstruction algorithm has been developed to deal with the broad bandwidth in ptychography. Compared with the latest development of mixed-state reconstruction approach, this multi-wavelength approach is more accurate in the physical model, and also considers the spot size variation as a function of energy due to the chromatic focusing optics. Therefore, this method has been proved in both simulation and experiment to significantly improve the reconstruction when the source bandwidth, illumination size and scan step size increase. It is worth mentioning that the accurate and detailed information of the energy spectrum for the incident beam is not required in advance for the proposed method. Further, we combine multi-wavelength and mixed-state approaches to jointly solve temporal and spatial partial coherence in ptychography so that it can handle various disadvantageous experimental effects. The significant relaxation in coherence requirements by our approaches allows the use of high-flux broadband X-ray sources for high-efficient and high-resolution ptychographic imaging.

4.
Rev Sci Instrum ; 90(8): 083701, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31472643

ABSTRACT

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 × 104 resolution elements per second.

5.
J Synchrotron Radiat ; 15(Pt 5): 427-32, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18728312

ABSTRACT

A dedicated high-resolution high-throughput X-ray powder diffraction beamline has been constructed at the Advanced Photon Source (APS). In order to achieve the goals of both high resolution and high throughput in a powder instrument, a multi-analyzer detector system is required. The design and performance of the 12-analyzer detector system installed on the powder diffractometer at the 11-BM beamline of APS are presented.


Subject(s)
X-Ray Diffraction/methods , Equipment Design/methods , Powder Diffraction/methods , Synchrotrons/instrumentation , X-Ray Diffraction/instrumentation
6.
J Synchrotron Radiat ; 15(Pt 1): 12-8, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18097073

ABSTRACT

The design and performance of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been commissioned at undulator beamline 8-ID-I at the Advanced Photon Source are presented. Details of the mechanical and optical design, control system implementation and performance of the new device are given. The monochromator was designed to meet the challenging stability and optical requirements of the X-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine-tuning the pitch and roll of the second crystal relative to the first crystal. The monochromator delivers an exceptionally uniform and stable beam and thereby improved brilliance preservation.