Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 85(24): 11732-8, 2013 Dec 17.
Article in English | MEDLINE | ID: mdl-24187941

ABSTRACT

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NIH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.


Subject(s)
Blood Chemical Analysis/standards , Metabolomics/standards , Adult , Amino Acids/blood , Biomarkers/blood , Carotenoids/blood , Fatty Acids/blood , Female , Humans , Male , National Institutes of Health (U.S.) , Reference Standards , United States , Vitamins/blood
2.
Anal Bioanal Chem ; 397(5): 1779-85, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20568655

ABSTRACT

The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.


Subject(s)
Blood Glucose/analysis , Gas Chromatography-Mass Spectrometry/methods , Carbon Isotopes/analysis , Gas Chromatography-Mass Spectrometry/instrumentation , Gas Chromatography-Mass Spectrometry/standards , Humans , Reference Standards
3.
Anal Bioanal Chem ; 397(2): 501-9, 2010 May.
Article in English | MEDLINE | ID: mdl-20333365

ABSTRACT

A new standard reference material (SRM) for drugs of abuse in human serum (SRM 1959) has been developed. This SRM is intended to be used as a control material for laboratories performing analysis of drugs of abuse in blood to evaluate the accuracy of their methods. SRM 1959 is a frozen human serum material fortified with seven compounds for which analyses are performed to determine evidence of illegal drug use: benzoylecgonine (BZE), methadone (METH), methamphetamine (MAMP), morphine (MOR), nordiazepam (NOR), phencyclidine (PCP), and 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THC-9-COOH). Two independent methods involving isotope dilution (ID)-gas chromatography/mass spectrometry (GC/MS) and ID-liquid chromatography/mass spectrometry (LC/MS) were used for the value assignment. For THC-9-COOH, an additional measurement using LC/tandem mass spectrometry (LC/MS/MS) was also included. All methods used isotopically labeled compounds as internal standards and solid-phase extractions to isolate the analytes from the serum. The GC/MS methods used different clean-up procedures from those used for the LC/MS-based methods. Repeatability with within-set coefficients of variation (CVs) ranged from 0.5% to 4.3% for the GC/MS methods and from 0.2% to 1.2% for the LC/MS-based methods. Intermediate precision with between-set CVs for all the methods ranged from 0.1% to 1.1%. Agreement between the GC/MS and LC/MS methods ranged from 0.8% to 8.8%. The results from the methods were combined to obtain the certified concentrations and their expanded uncertainties.


Subject(s)
Illicit Drugs/blood , Substance Abuse Detection/methods , Adult , Chromatography, Liquid/methods , Gas Chromatography-Mass Spectrometry/methods , Humans , Reference Standards , Sensitivity and Specificity , Solid Phase Extraction/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...