Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 154
Filter
1.
Can J Cardiol ; 40(3): 457-467, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37923124

ABSTRACT

BACKGROUND: The risks of prefrail and frail women undergoing transcatheter aortic valve replacement (TAVR) have not been fully examined. The aim of the analysis was to assess the prognostic impact of prefrailty and frailty in women undergoing TAVR. METHODS: Women at intermediate or high surgical risk with severe aortic stenosis undergoing TAVR from the prospective multicentre WIN-TAVI (Women's International Transcatheter Aortic Valve Implantation) registry were stratified based on the number of Fried frailty criteria (weight loss, exhaustion, low physical activity, slow gait, weakness) met: nonfrail (no criteria), prefrail (1 or 2 criteria), or frail (3 or more criteria). The primary outcome at 1 year was the Valve Academic Research Consortium 2 (VARC-2) efficacy end point, a composite of mortality, stroke, myocardial infarction, hospitalisation for valve-related symptoms or heart failure, and valve-related dysfunction; secondary outcomes included the composite of VARC-2 life-threatening or major bleeding. RESULTS: Out of 1019 women, 297 (29.1%) met at least 1 frailty criterion: 264 (25.9%) had prefrailty and 33 (3.2%) frailty. The 1-year risk of the primary outcome was significantly higher in prefrail and frail (20.2%) than in nonfrail (14.9%) women (adjusted hazard ratio [aHR] 1.51, 95% confidence interval [CI] 1.07-2.12). The risk of VARC-2 life-threatening or major bleeding was higher in prefrail or frail (19.9%) than in nonfrail (10.0%) women (aHR 2.06, 95% CI 1.42-2.97). These risks were consistently increased in the prefrail and frail groups assessed separately. CONCLUSIONS: In women undergoing TAVR, the presence of prefrailty or frailty conferred an increased risk of the VARC-2 efficacy end point and of VARC-2 life-threatening or major bleeding.


Subject(s)
Aortic Valve Stenosis , Frailty , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Frailty/complications , Frailty/epidemiology , Frailty/diagnosis , Prognosis , Risk Factors , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Risk Assessment , Prospective Studies , Treatment Outcome , Hemorrhage/etiology , Registries , Aortic Valve/surgery
2.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Article in English | MEDLINE | ID: mdl-37968032

ABSTRACT

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Subject(s)
Atrial Fibrillation , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Constriction, Pathologic/etiology , Treatment Outcome , Cardiac Catheterization/adverse effects , Hemodynamics , Registries , Prosthesis Design
3.
Am J Cardiol ; 192: 221-227, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36848691

ABSTRACT

Early menopause is associated with an increased risk of cardiovascular diseases, including aortic stenosis (AS). We sought to investigate the prevalence and impact of early menopause on clinical outcomes in patients who underwent transcatheter aortic valve implantation (TAVI) for severe symptomatic AS. Women's International TAVI is a multinational, prospective, observational registry of women who underwent TAVI for severe symptomatic AS (n = 1,019). Patients were divided into 2 groups based on age of menopause: early menopause (age ≤45 years) and regular menopause (age >45 years). The primary outcome of interest was Valve Academic Research Consortium 2 efficacy end point, a composite of mortality, stroke, myocardial infarction, hospitalization for valve-related symptoms, or heart failure or valve-related dysfunction at 1-year follow-up. Of 732 patients with available data on menopause age, 173 (23.6%) were classified as having early menopause. These patients presented for TAVI at a younger age (81.6 ± 6.9 vs 82.7 ± 5.9, p = 0.05) and had a significantly lower Society of Thoracic Surgeons score (6.6 ± 4.8 vs 8.2 ± 7.1, p = 0.03) than those with regular menopause. However, the total valve calcium volume was smaller among patients with early versus regular menopause (731.8 ± 850.9 mm3 vs 807.6 ± 633.8 mm3, p = 0.002). Other co-morbidities were similar between the 2 groups. At 1-year follow-up, there were no significant differences in clinical outcomes between patients with early versus regular menopause (hazard ratio 1.00, 95% confidence interval 0.61 to 1.63, p = 1.00). In conclusion, despite presenting for TAVI at a younger age, patients with early menopause had a similar risk of adverse events as patients with regular menopause at 1 year after TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Risk Factors , Treatment Outcome , Aortic Valve Stenosis/surgery , Menopause , Aortic Valve/surgery
4.
Int J Cardiol ; 372: 40-45, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36455701

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become an accepted treatment for patients with severe aortic stenosis (AS). Predicting which patients are at risk for adverse clinical outcomes after TAVI remains difficult, especially in women. AIM: To identify predictors of adverse events in the WIN-TAVI cohort. METHODS: The WIN-TAVI study is an observational registry of 1019 women undergoing TAVI for severe symptomatic AS. Follow-up was 1 year. The primary outcome was defined according to VARC-2: a composite of mortality, stroke, myocardial infarction or hospitalization for valve-related symptoms or heart failure. The secondary outcome was a composite of cardiovascular mortality or hospitalization for valve-related symptoms or heart failure. RESULTS: We included 1019 women with severe AS (mean age of 82.5 ± 6.3 years). At 1 year, 16.4% of the patients experienced the primary endpoint and 12.6% the secondary endpoint. The use of oral anticoagulants (OAC) was the strongest independent predictor of the primary outcome (adjusted hazard ratio [aHR] 1.51, 95% confidence interval [CI] 1.079-2.106, p = 0.016). Independent predictors of the secondary endpoint were age (aHR 1.04 per year, 95% CI 1.01-1.074, p = 0.016) and use of OAC (aHR: 1.79, 95% CI 1.24-2.60, p = 0.002). OAC use was not associated with higher bleeding risk. CONCLUSION: Pre-procedural use of OAC was the strongest predictor of adverse outcomes during 1-year follow-up, likely reflecting a combination of high-risk factors and comorbidities, but was not related to increased bleeding risk.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Anticoagulants/adverse effects , Treatment Outcome , Risk Factors , Heart Failure/etiology
5.
Am J Cardiol ; 172: 73-80, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35461697

ABSTRACT

Although most patients with small aortic annulus are women, there is paucity of data on the prognostic impact of small aortic prosthesis in women who underwent transcatheter aortic valve implantation (TAVI). Therefore, we aimed to evaluate the impact of small valve size on 1-year clinical outcomes after TAVI in women. The Women's INternational Transcatheter Aortic Valve Implantation is an all-women registry evaluating patients with severe aortic stenosis who underwent TAVI. Based on the size of the aortic bioprosthesis implanted, women were stratified into small (≤23 mm) and nonsmall (>23 mm) valve. The primary efficacy endpoint was the Valve Academic Research Consortium-2 composite of all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction at 1-year follow-up. Of 934 women who underwent TAVI, 388 (41.5%) received a small valve. Women with a small valve size had a lower body mass index, lower surgical risk scores, were less likely to suffer from atrial fibrillation, less often required postdilation and had a lower rate of residual aortic regurgitation grade ≥2. The occurrence of the Valve Academic Research Consortium-2 efficacy endpoint was similar between women treated with small and nonsmall valve (16.0% vs 16.3%, p = 0.881; adjusted hazard ratio 1.34, 95% confidence interval 0.90 to 2.00). Likewise, there were no significant differences in the occurrence of other secondary endpoints after multivariable adjustment. In conclusion, women with severe aortic stenosis who underwent TAVI with the implantation of a small valve bioprosthesis had similar 1-year outcomes as those receiving a nonsmall bioprosthesis.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Female , Humans , Male , Registries , Risk Factors , Time Factors , Treatment Outcome
6.
J Am Heart Assoc ; 11(6): e023454, 2022 03 15.
Article in English | MEDLINE | ID: mdl-35114814

ABSTRACT

Background It is unknown whether contemporary drug-eluting stents have a similar safety profile in high bleeding risk patients treated with 1-month dual antiplatelet therapy following percutaneous coronary interventions. Methods and Results We performed an interventional, prospective, multicenter, single-arm trial, powered for noninferiority with respect to an objective performance criterion to evaluate the safety of percutaneous coronary interventions with Synergy bioresorbable-polymer everolimus-eluting stent followed by 1-month dual antiplatelet therapy in patients with high bleeding risk. In case of need for an oral anticoagulant, patients received an oral anticoagulant in addition to a P2Y12 inhibitor for 1 month, followed by an oral anticoagulant only. The primary end point was the composite of cardiac death, myocardial infarction, or definite or probable stent thrombosis at 1-year follow-up. The study was prematurely interrupted because of slow recruitment. From April 2017 to October 2019, 443 patients (age, 74.8±9.2 years; women, 29.1%) at 10 Italian centers were included. The 1-year primary outcome occurred in 4.82% (95% CI, 3.17%-7.31%) of patients, meeting the noninferiority compared with the predefined objective performance criterion of 9.4% and the noninferiority margin of 3.85% (Pnoninferiority<0.001) notwithstanding the lower-than-expected sample size. The rates of cardiac death, myocardial infarction, and definite or probable stent thrombosis were 1.88% (95% CI, 0.36%-2.50%), 3.42% (95% CI, 2.08%-5.62%), and 0.94% (95% CI, 0.35%-2.49%), respectively. Conclusions Among high bleeding risk patients undergoing percutaneous coronary interventions with the Synergy bioresorbable-polymer everolimus-eluting stent, a 1-month dual antiplatelet therapy regimen is safe, with low rates of ischemic and bleeding events. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03112707.


Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Thrombosis , Absorbable Implants , Aged , Aged, 80 and over , Anticoagulants , Death , Drug-Eluting Stents/adverse effects , Everolimus/adverse effects , Female , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/adverse effects , Polymers , Prospective Studies , Thrombosis/etiology , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 98(6): E908-E917, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34117817

ABSTRACT

OBJECTIVES: To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. BACKGROUND: Data on pacemaker insertion complicating TAVR in women are scarce. METHODS: The Women's International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. RESULTS: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85-7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30-0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9-16] days in PPI vs. 9 [7-14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adj HR 0.95, 95% CI 0.60-1.52, p = 0.84 and adj HR 1.22, 95% CI 0.83-1.79, p = 0.31, respectively). CONCLUSION: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Incidence , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32865860

ABSTRACT

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Female , Humans , Postoperative Complications , Prevalence , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
Int J Cardiol ; 322: 65-69, 2021 01 01.
Article in English | MEDLINE | ID: mdl-32814108

ABSTRACT

BACKGROUND: Female subjects constitute half of all transcatheter aortic valve implantation (TAVI) candidates, but the association between important comorbidities such as diabetes mellitus (DM) and clinical outcomes after TAVI remains unclear in this group. METHOD: WIN-TAVI is a real-world international registry of exclusively female subjects undergoing TAVI. The study population was stratified into those with (DM) and those without DM (NDM). Valve Academic Research Consortium (VARC)-2 efficacy (composite of all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or worsening congestive heart failure, or valve-related dysfunction) was the primary endpoint for this analysis. RESULTS: Of the 1012 subjects included in this study, 264 (26.1%) had DM at baseline. DM patients were younger but had a higher burden of comorbidities. There were no differences in VARC-2 efficacy events between DM and NDM patients at 30 days or 1 year. Conversely, patients with DM had a lower risk of VARC-2 life threatening bleeding at 30 days and 1 year after TAVI compared to NDM patients, which remained significant even after multivariable adjustment (HR, 0.34, 95% CI, 0.12-0.99; p = .047). In the subgroup analysis, insulin-dependent DM was not associated with an increased risk of adverse outcomes. CONCLUSIONS: Among female patients undergoing TAVI, more than one-fourth of the subjects presented with DM. At 1-year follow-up, DM was associated with lower bleeding complications and no increase in the risk of other adverse events, including mortality, after TAVI.


Subject(s)
Aortic Valve Stenosis , Diabetes Mellitus , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Diabetes Mellitus/diagnosis , Diabetes Mellitus/epidemiology , Female , Humans , Registries , Risk Assessment , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
11.
Catheter Cardiovasc Interv ; 97(5): E704-E715, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33002302

ABSTRACT

OBJECTIVES: To assess the impact of anemia on clinical outcomes in female patients enrolled in the Women's InterNational transcatheter aortic valve implantation (WIN-TAVI) registry. BACKGROUND: Anemia is highly prevalent among females who constitute half of TAVI candidates, yet, its clinical significance remains poorly investigated. METHODS: Patients were divided into three groups according to preprocedural hemoglobin (Hb) level: (1) no anemia (Hb ≥12 g/dl), (2) mild-to-moderate anemia (10 ≤ Hb <12 g/dl), and (3) severe anemia (Hb <10 g/dl). The primary outcome was the occurrence of Valve Academic Research Consortium (VARC)-2 efficacy endpoint, a composite of mortality, stroke, myocardial infarction (MI), hospitalization for valve-related symptoms or heart failure or valve-related dysfunction at 1-year follow-up. RESULTS: Hemoglobin level was available in 877 (86.1%) patients: 412 (47.0%) had no anemia, 363 (41.4%) had mild-to-moderate anemia, and 102 (11.6%) had severe anemia. The latter group had a higher prevalence of cardiovascular risk factors. Compared with patients without anemia, severe anemia was associated with a greater risk of VARC-2 efficacy endpoint (adj HR 1.71, 95% CI: 1.02-2.87, p = .04), all-cause death (adj HR 2.36, 95% CI: 1.31-4.26, p = .004) and a composite of death, MI or stroke (adj HR 1.88, 95% CI: 1.10-3.22, p = .02) at 1 year. Moreover, an increased risk of late mortality (adj HR 1.15, 95% CI: 1.02-1.30, p = .03) was observed with every 1 g/dl decrease in hemoglobin level. CONCLUSION: Severe anemia in females undergoing TAVI was independently associated with increased rates of VARC-2 efficacy endpoint and mortality at 1 year.


Subject(s)
Anemia , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Anemia/epidemiology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
Circ Cardiovasc Interv ; 13(7): e008714, 2020 07.
Article in English | MEDLINE | ID: mdl-32646304

ABSTRACT

BACKGROUND: Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis. METHODS: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve. RESULTS: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P=0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P=0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P=0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P=0.043). CONCLUSIONS: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/physiopathology , Europe , Feasibility Studies , Female , Hemodynamics , Humans , Male , Prosthesis Design , Recovery of Function , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Article in English | MEDLINE | ID: mdl-32592401

ABSTRACT

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Female , Humans , Male , Prosthesis Design , Prosthesis Failure , Treatment Outcome
15.
Catheter Cardiovasc Interv ; 96(1): 198-207, 2020 07.
Article in English | MEDLINE | ID: mdl-31977142

ABSTRACT

BACKGROUND: The prevalence of both chronic kidney disease (CKD) and aortic stenosis (AS) increase with age. Although baseline CKD is frequent in patients undergoing transcatheter aortic valve replacement (TAVR), its significance among women is largely unknown. METHODS: Women's INternational Transcatheter Aortic Valve Implantation (WIN-TAVI) is a multinational, prospective registry of women undergoing TAVR for severe AS. We included patients with available baseline estimated glomerular filtration rate (eGFR) and completed 1-year follow-up. Patients were categorized into three groups based on their eGFR: No CKD (normal kidney function to stage 2 CKD: eGFR ≥60 ml/min/1.73 m2 ); (b) mild CKD (stage 3a CKD: eGFR = 45-59 ml/min/1.73 m2 ); and (c) moderate/severe CKD (stage ≥3b CKD: eGFR <45 ml/min/1.73 m2 ). All events were adjudicated according to the Valve Academic Research Consortium (VARC)-2 criteria. RESULT: Out of 852 women undergoing TAVR, 326 (38.3%) had no CKD, 225 (26.4%) had mild CKD, and 301 (35.3%) had moderate/severe CKD. Women with higher stage of CKD at baseline were more likely to have a history of hypertension, diabetes, atrial fibrillation, anemia, chronic lung disease, hemodialysis, prior percutaneous coronary intervention, and pacemaker implantation. After multivariate adjustment, moderate/severe CKD was associated with a greater risk of 1-year VARC-2 safety endpoints [hazard ratio (HR) 1.68, 95% confidence interval (CI): 1.10-2.60], all-cause death (HR 2.00, 95% CI: 1.03-3.90), and composite of death, myocardial infarction, stroke or life-threatening bleeding (HR 1.70, 95% CI: 1.04-2.76). There were no differences in 30-day and 1-year VARC-2 efficacy and 30-day VARC-2 safety outcomes. CONCLUSION: CKD is associated with substantial and independent risk for mortality and morbidity at 1-year follow-up in women undergoing TAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Glomerular Filtration Rate , Humans , Kidney/physiopathology , Registries , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/mortality , Renal Insufficiency, Chronic/physiopathology , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Sex Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
16.
Heart ; 106(7): 487-492, 2020 04.
Article in English | MEDLINE | ID: mdl-31932287

ABSTRACT

There are important dissimilarities in clinical presentation, aggregation of comorbidities, cardiovascular risk factors and the quality of delivery of medical care among men and women with acute coronary syndrome (ACS). Compared with men, despite the well-known older age and more pronounced frailty, women with ACS present later from symptom onset and are at high bleeding risk after invasive procedures. In addition, autoimmune/inflammatory disease, fibromuscular dysplasia, polycystic ovary, early menopause and history of pre-eclampsia are risk factors preceding ACS among younger women. They more often experience myocardial infarction in the absence of obstructive coronary arteries (MINOCA), which makes diagnosis and treatment of ACS among women more challenging compared with men. Women and men do both benefit from guideline-recommended treatment, although, compared with men, women with ACS have a higher adjusted risk of early death, which equalises between both sexes within the first year. Young women with ACS suffer frequently of depression and present often with MINOCA. Compared with young men, they (young women) have a higher risk of death. Therefore, focusing on young patients with ACS, understanding the particular physiopathology of MINOCA and developing programmes targeting comorbidities and depression-related behavioural risk factors are urgently needed.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy , Coronary Artery Disease/diagnosis , Coronary Artery Disease/therapy , Female , Humans , Women's Health
17.
Am J Cardiol ; 125(3): 441-448, 2020 02 01.
Article in English | MEDLINE | ID: mdl-31813530

ABSTRACT

We sought to analyze outcomes of women receiving balloon-expandable valves (BEV) or self-expanding valves (SEV) in contemporary transcatheter aortic valve implantation (TAVI). WIN TAVI (Women's INternational Transcatheter Aortic Valve Implantation) is the first all-female TAVI registry to study the safety and performance of TAVI in women. We compared women treated with BEV (n = 408, 46.9%) versus those treated with SEV (n = 461, 53.1%). The primary efficacy end point was the Valve Academic Research Consortium-2 (VARC-2) composite of 1-year all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction. Women receiving SEV had higher surgical risk scores, higher rate of previous stroke and pulmonary hypertension whereas women receiving BEV were more frequently denied surgical valve replacement due to frailty. BEV patients were less likely to require post-dilation and had significantly lower rates of residual aortic regurgitation grade ≥2 (9.8% vs 4.7%, p = 0.007). At 1 year, the crude incidence and adjusted risk of the primary VARC-2 efficacy end point was similar between groups (17.1% with SEV and 14.3% with BEV, p = 0.25; hazards ratio 1.09, 95% confidence interval 0.68 to 1.75). Conversely the crude rate and adjusted risk of new pacemaker implantation was higher with SEV than BEV (15% vs 8.6%, p = 0.001; hazards ratio 1.97, 95% confidence interval 1.13 to 3.43). A subanalysis on new generation valves showed no difference in the need for pacemaker implantation between the 2 devices (10.1% vs 8.0%, p = 0.56). In conclusion, in contemporary TAVI, SEV are used more frequently in women with greater co-morbidities. While there were no differences in unadjusted and adjusted risk of 1-year primary efficacy end point between the valve types, there was a greater need for permanent pacemakers after SEV implantation.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Postoperative Complications/epidemiology , Registries , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Cause of Death/trends , Europe/epidemiology , Female , Humans , Incidence , Multidetector Computed Tomography/methods , Postoperative Complications/diagnosis , Prosthesis Design , Risk Factors , Survival Rate/trends , Treatment Outcome , United States/epidemiology
19.
JACC Cardiovasc Interv ; 12(16): 1566-1576, 2019 08 26.
Article in English | MEDLINE | ID: mdl-31202946

ABSTRACT

OBJECTIVES: The purpose of the study was to investigate the impact of oral anticoagulation (OAC) type on clinical outcomes 1 year after transcatheter aortic valve replacement (TAVR). BACKGROUND: Non-vitamin K oral anticoagulants (NOACs) are superior to vitamin K antagonists (VKAs) in nonvalvular atrial fibrillation (AF), while their comparative performance among patients in need of OAC undergoing TAVR is underinvestigated. METHODS: The study enrolled 962 consecutive patients who underwent TAVR in 4 tertiary European centers and were discharged on either NOACs (n = 326) or VKAs (n = 636). By using propensity scores for inverse probability of treatment weighting (IPTW), the comparison of treatment groups was adjusted to correct for potential confounding. RESULTS: Mean age and Society of Thoracic Surgeons score of the population were 81.3 ± 6.3 years and 4.5% (interquartile range: 3.0% to 7.3%); 52.5% were women and a balloon-expandable valve was used in 62.7% of cases. The primary outcome of interest, combined incidence of all-cause mortality, myocardial infarction, and any cerebrovascular event at 1-year after TAVR, was 21.2% with NOACs versus 15.0% with VKAs (hazard ratio [HR]: 1.44; 95% confidence interval [CI]: 1.00 to 2.07; p = 0.050, IPTW-adjusted). The 1-year incidence of any Bleeding Academic Research Consortium bleeds and all-cause mortality were comparable between the NOAC and VKA groups, 33.9% versus 34.1% (HR: 0.97; 95% CI: 0.74 to 1.26; p = 0.838, IPTW-adjusted) and 16.5% versus 12.2% (HR: 1.36; 95% CI: 0.90 to 2.06; p = 0.136, IPTW-adjusted), respectively. CONCLUSIONS: Chronic use of both NOACs and VKAs among patients in need of OAC after TAVR are comparable regarding 1-year bleeding risk. The higher ischemic event rate observed with NOACs needs to be evaluated in large randomized trials.


Subject(s)
Anticoagulants/administration & dosage , Aortic Valve Stenosis/surgery , Atrial Fibrillation/drug therapy , Fibrinolytic Agents/administration & dosage , Transcatheter Aortic Valve Replacement , Administration, Oral , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Europe , Factor Xa Inhibitors/administration & dosage , Female , Fibrinolytic Agents/adverse effects , Hemorrhage/chemically induced , Hemorrhage/mortality , Humans , Male , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Vitamin K/antagonists & inhibitors
SELECTION OF CITATIONS
SEARCH DETAIL
...