Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Radiat Isot ; 70(4): 602-8, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22326369

ABSTRACT

In this work the production of (64)Cu via the (64)Ni(p,n)(64)Cu reaction with optimized conditions for low current irradiation is presented. Different target setups and cleaning steps for lowering metal contaminations in the product were applied. (64)Cu with high specific activities up to 1685 GBq/µmol was produced despite low overall activity (≈ 4.2 GBq per run). The module processing leads to a highly reproducible, reliable product quality (<1 µg Cu and <7 µg Ni). Besides its diagnostic value (64)Cu may be of interest even for therapeutic purposes due to its decay characteristics.


Subject(s)
Copper Radioisotopes/chemistry , Radiopharmaceuticals/chemical synthesis , Nickel , Radioactive Waste/prevention & control , Radioactivity
2.
Nuklearmedizin ; 47(3): 116-9, 2008.
Article in English | MEDLINE | ID: mdl-18493691

ABSTRACT

AIM: Characterisation of the influence of different polymeric tube materials of a water target system, used for the production of 18F activity, on the specific activity of radiotracers. MATERIAL, METHODS: Target water samples taken from different locations of the 18F water target system of a Cyclone 18/9 cyclotron, equipped with Teflon (PTFE) or polypropylene (PP) tubes, were analyzed for non-radioactive [19F]fluoride content. [19F]Fluoride content was measured by ion chromatography (IC20, Dinoex) with suppressed conductivity detection. Both the ion chromatographic results and the amount of 18F activity produced were used for the calculation of the specific activity (SA) of [18F]fluoride at the start of the labelling synthesis. To check these results, the SA of the labelled receptor ligand [18F]ZK811460 was also determined by using the different tubing materials. RESULTS: Dose-exposed PTFE tubes of the target dispensing (loading) system were identified to be a major source of [19F]fluoride contamination. CONCLUSION: By replacing PTFE tubes of the target dispensing system with PP tubes, the content of 19F was reduced considerably resulting in an increase of SA of the radiotracer [18F]ZK811460 by factor of two.


Subject(s)
Fluorides/analysis , Fluorine Radioisotopes/analysis , Oxygen Isotopes , Water , Cyclotrons , Drug Contamination/prevention & control , Polypropylenes , Polytetrafluoroethylene
SELECTION OF CITATIONS
SEARCH DETAIL
...