Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Food Chem ; 340: 127904, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-32890856

ABSTRACT

The present study aims at developing an analytical methodology which allows correlating sensory poles of chocolate to their chemical characteristics and, eventually, to those of the cocoa beans used for its preparation. Trained panelists investigated several samples of chocolate, and they divided them into four sensorial poles (characterized by 36 different descriptors) attributable to chocolate flavor. The same samples were analyzed by six different techniques: Proton Transfer Reaction-Time of Flight-Mass Spectrometry (PTR-ToF-MS), Solid Phase Micro Extraction-Gas Chromatography-Mass Spectroscopy (SPME-GC-MS), High-Performance Liquid Chromatography (HPLC) (for the quantification of eight organic acids), Ultra High Performance Liquid Chromatography coupled to triple-quadrupole Mass Spectrometry (UHPLC-QqQ-MS) for polyphenol quantification, 3D front face fluorescence Spectroscopy and Near Infrared Spectroscopy (NIRS). A multi-block classification approach (Sequential and Orthogonalized-Partial Least Squares - SO-PLS) has been used, in order to exploit the chemical information to predict the sensorial poles of samples. Among thirty-one test samples, only two were misclassified.


Subject(s)
Cacao/chemistry , Chocolate/analysis , Chocolate/classification , Food Analysis/methods , Chromatography, High Pressure Liquid , Food Analysis/statistics & numerical data , Gas Chromatography-Mass Spectrometry/methods , Humans , Least-Squares Analysis , Mass Spectrometry/methods , Polyphenols/analysis , Solid Phase Microextraction , Spectrometry, Fluorescence , Spectroscopy, Near-Infrared , Taste
2.
Metabolites ; 10(8)2020 Jul 29.
Article in English | MEDLINE | ID: mdl-32751281

ABSTRACT

Chocolate quality is largely due to the presence of polyphenols and especially of flavan-3-ols and their derivatives that contribute to bitterness and astringency. The aim of the present work was to assess the potential of a quantitative polyphenol targeted metabolomics analysis based on mass spectrometry for relating cocoa bean polyphenol composition corresponding chocolate polyphenol composition and sensory properties. One-hundred cocoa bean samples were transformed to chocolates using a standard process, and the latter were attributed to four different groups by sensory analysis. Polyphenols were analyzed by an ultra-high-performance liquid chromatography (UPLC) system hyphenated to a triple quadrupole mass spectrometer. A multiblock method called a Common Component and Specific Weights Analysis (CCSWA) was used to study relationships between the three datasets, i.e., cocoa polyphenols, chocolate polyphenols and sensory profiles. The CCSWA multiblock method coupling sensory and chocolate polyphenols differentiated the four sensory poles. It showed that polyphenolic and sensory data both contained information enabling the sensory poles' separation, even if they can be also complementary. A large amount of variance in the cocoa bean and corresponding chocolate polyphenols has been linked. The cocoa bean phenolic composition turned out to be a major factor in explaining the sensory pole separation.

3.
J Mass Spectrom ; 54(1): 92-119, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30478865

ABSTRACT

Direct-injection mass spectrometry (DIMS) techniques have evolved into powerful methods to analyse volatile organic compounds (VOCs) without the need of chromatographic separation. Combined to chemometrics, they have been used in many domains to solve sample categorization issues based on volatilome determination. In this paper, different DIMS methods that have largely outperformed conventional electronic noses (e-noses) in classification tasks are briefly reviewed, with an emphasis on food-related applications. A particular attention is paid to proton transfer reaction mass spectrometry (PTR-MS), and many results obtained using the powerful PTR-time of flight-MS (PTR-ToF-MS) instrument are reviewed. Data analysis and feature selection issues are also summarized and discussed. As a case study, a challenging problem of classification of dark chocolates that has been previously assessed by sensory evaluation in four distinct categories is presented. The VOC profiles of a set of 206 chocolate samples classified in the four sensory categories were analysed by PTR-ToF-MS. A supervised multivariate data analysis based on partial least squares regression-discriminant analysis allowed the construction of a classification model that showed excellent prediction capability: 97% of a test set of 62 samples were correctly predicted in the sensory categories. Tentative identification of ions aided characterisation of chocolate classes. Variable selection using dedicated methods pinpointed some volatile compounds important for the discrimination of the chocolates. Among them, the CovSel method was used for the first time on PTR-MS data resulting in a selection of 10 features that allowed a good prediction to be achieved. Finally, challenges and future needs in the field are discussed.


Subject(s)
Chocolate/analysis , Volatile Organic Compounds/analysis , Food Quality , Mass Spectrometry/methods , Sensation
4.
Int J Pharm ; 473(1-2): 219-31, 2014 Oct 01.
Article in English | MEDLINE | ID: mdl-25003830

ABSTRACT

The implementation of a blend monitoring and control method based on a process analytical technology such as near infrared spectroscopy requires the selection and optimization of numerous criteria that will affect the monitoring outputs and expected blend end-point. Using a five component formulation, the present article contrasts the modeling strategies and end-point determination of a traditional quantitative method based on the prediction of the blend parameters employing partial least-squares regression with a qualitative strategy based on principal component analysis and Hotelling's T(2) and residual distance to the model, called Prototype. The possibility to monitor and control blend homogeneity with multivariate curve resolution was also assessed. The implementation of the above methods in the presence of designed experiments (with variation of the amount of active ingredient and excipients) and with normal operating condition samples (nominal concentrations of the active ingredient and excipients) was tested. The impact of criteria used to stop the blends (related to precision and/or accuracy) was assessed. Results demonstrated that while all methods showed similarities in their outputs, some approaches were preferred for decision making. The selectivity of regression based methods was also contrasted with the capacity of qualitative methods to determine the homogeneity of the entire formulation.


Subject(s)
Chemistry, Pharmaceutical/methods , Models, Theoretical , Acetaminophen/chemistry , Carboxymethylcellulose Sodium/chemistry , Cellulose/chemistry , Excipients/chemistry , Lactose/chemistry , Least-Squares Analysis , Principal Component Analysis , Spectroscopy, Near-Infrared , Stearic Acids/chemistry
5.
Phytochemistry ; 69(18): 3131-8, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18455206

ABSTRACT

Lower molecular weight polyphenols including proanthocyanidin oligomers can be analyzed after HPLC separation on either reversed-phase or normal phase columns. However, these techniques are time consuming and can have poor resolution as polymer chain length and structural diversity increase. The detection of higher molecular weight compounds, as well as the determination of molecular weight distributions, remain major challenges in polyphenol analysis. Approaches based on direct mass spectrometry (MS) analysis that are proposed to help overcome these problems are reviewed. Thus, direct flow injection electrospray ionization mass spectrometry analysis can be used to establish polyphenol fingerprints of complex extracts such as in wine. This technique enabled discrimination of samples on the basis of their phenolic (i.e. anthocyanin, phenolic acid and flavan-3-ol) compositions, but larger oligomers and polymers were poorly detectable. Detection of higher molecular weight proanthocyanidins was also restricted with matrix-assisted laser desorption ionization (MALDI) MS, suggesting that they are difficult to desorb as gas-phase ions. The mass distribution of polymeric fractions could, however, be determined by analyzing the mass distributions of bovine serum albumin/proanthocyanidin complexes using MALDI-TOF-MS.


Subject(s)
Complex Mixtures/chemistry , Flavonoids/chemistry , Mass Spectrometry/methods , Phenols/chemistry , Molecular Structure , Polyphenols , Proanthocyanidins/chemistry , Wine/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...