Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 21002, 2023 11 28.
Article in English | MEDLINE | ID: mdl-38017262

ABSTRACT

The accuracy of three-dimensional (3D) facial skeletal surface models derived from radiographic volumes has not been extensively investigated yet. For this, ten human dry skulls were scanned with two Cone Beam Computed Tomography (CBCT) units, a CT unit, and a highly accurate optical surface scanner that provided the true reference models. Water-filled head shells were used for soft tissue simulation during radiographic imaging. The 3D surface models that were repeatedly segmented from the radiographic volumes through a single-threshold approach were used for reproducibility testing. Additionally, they were compared to the true reference model for trueness measurement. Comparisons were performed through 3D surface approximation techniques, using an iterative closest point algorithm. Differences between surface models were assessed through the calculation of mean absolute distances (MAD) between corresponding surfaces and through visual inspection of facial surface colour-coded distance maps. There was very high reproducibility (approximately 0.07 mm) and trueness (0.12 mm on average, with deviations extending locally to 0.5 mm), and no difference between radiographic scanners or settings. The present findings establish the validity of lower radiation CBCT imaging protocols at a similar level to the conventional CT images, when 3D surface models are required for the assessment of facial morphology.


Subject(s)
Spiral Cone-Beam Computed Tomography , Humans , Reproducibility of Results , Imaging, Three-Dimensional/methods , Skull/diagnostic imaging , Face/diagnostic imaging
2.
Sci Rep ; 12(1): 22549, 2022 12 29.
Article in English | MEDLINE | ID: mdl-36581665

ABSTRACT

In radiology research soft tissues are often simulated on bone specimens using liquid materials such as water, or gel-like materials, such as ballistic gel. This study aimed to test the effect of hydration on the anatomical form of dry craniofacial bone specimens. Sixteen human dry skulls and 16 mandibles were scanned with an industrial scanner in dry conditions and after water embedding. Ten skulls were also embedded for different time periods (5 or 15 min). The subsequent 3D surface models were best-fit superimposed and compared by calculating mean absolute distances between them at various measurement areas. There was a significant, primarily enlargement effect of hydration on the anatomical form of dry skeletal specimens as detected after water embedding for a short time period. The effect was smaller in dry skulls (median 0.20 mm, IQR 0.17 mm) and larger in mandibles (median 0.56 mm, IQR 0.57 mm). The effect of different water embedding times was negligible. Based on the present findings, we suggest to shortly hydrate the skeletal specimens prior to reference model acquisition so that they are comparable to hydrated specimens when liquid materials are used as soft-tissue simulants for various radiologic research purposes.


Subject(s)
Mandible , Skull , Humans , Skull/diagnostic imaging , Mandible/diagnostic imaging , Water
3.
Diagnostics (Basel) ; 12(9)2022 Sep 18.
Article in English | MEDLINE | ID: mdl-36140652

ABSTRACT

Three-dimensional surface scans of skeletal structures have various clinical and research applications in medicine, anthropology, and other relevant fields. The aim of this study was to test the precision of a widely used hand-held surface scanner and the associated software's 3D model generation-error in both dry and wet skeletal surfaces. Ten human dry skulls and ten mandibles (dry and wet conditions) were scanned twice with an industrial scanner (Artec Space Spider) by one operator. Following a best-fit superimposition of corresponding surface model pairs, the mean absolute distance (MAD) between them was calculated on ten anatomical regions on the skulls and six on the mandibles. The software's 3D model generation process was repeated for the same scan of four dry skulls and four mandibles (wet and dry conditions), and the results were compared in a similar manner. The median scanner precision was 31 µm for the skulls and 25 µm for the mandibles in dry conditions, whereas in wet conditions it was slightly lower at 40 µm for the mandibles. The 3D model generation-error was negligible (range: 5-10 µm). The Artec Space Spider scanner exhibits very high precision in the scanning of dry and wet skeletal surfaces.