Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Prosthet Dent ; 110(5): 389-96, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24011801

ABSTRACT

STATEMENT OF PROBLEM: The predictable nature of the hot pressing ceramic technique has several applications, but no study was identified that evaluated its application to the fabrication of custom implant abutments. PURPOSE: The purpose of this study was to compare the fracture resistance of an experimentally designed pressable metal ceramic custom implant abutment (PR) with that of a duplicate zirconia abutment (ZR). MATERIALS AND METHODS: Two groups of narrow platform (NP) (Nobel Replace) implant abutment specimens were fabricated (n=10). The experimental abutment (PR) had a metal substructure cast with ceramic alloy (Lodestar) and veneered with leucite pressable glass ceramic (InLine PoM). Each PR abutment was individually scanned and 10 duplicate CAD/CAM ZR abutments were fabricated for the control group. Ceramic crowns (n=20) with the average dimensions of a human lateral incisor were pressed with lithium disilicate glass ceramic (IPS e.max Press) and bonded on the abutments with a resin luting agent (Multilink Automix). The specimens were subjected to thermocycling, cyclic loading, and finally static loading to failure with a computer-controlled Universal Testing Machine. An independent t test (1 sided) determined whether the mean values of the fracture load differed significantly (α=.05) between the 2 groups. RESULTS: No specimen failed during cyclic loading. Upon static loading, the mean (SD) load to failure was significantly higher for the PR group (525.89 [143.547] N) than for the ZR group (413.70 [35.515] N) for internal connection narrow platform bone-level implants (P=.025). Failure was initiated at the screw and internal connection level for both groups. CONCLUSIONS: It is possible to fabricate PR abutments that are stronger than ZR abutments for Nobel Biocare internal connection NP bone-level implants. The screw and the internal connection are the weak links for both groups.


Subject(s)
Computer-Aided Design , Dental Abutments , Dental Implant-Abutment Design , Dental Materials/chemistry , Metal Ceramic Alloys/chemistry , Zirconium/chemistry , Aluminum Silicates/chemistry , Ceramics/chemistry , Crowns , Dental Porcelain/chemistry , Dental Prosthesis Design , Dental Restoration Failure , Dental Stress Analysis/instrumentation , Humans , Materials Testing , Resin Cements/chemistry , Stress, Mechanical , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...