Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Cardiol J ; 31(1): 124-132, 2024.
Article in English | MEDLINE | ID: mdl-37519054

ABSTRACT

BACKGROUND: The aim of the study was to evaluate bio-functionality of a novel, proprietary balloon-expandable biological transcatheter aortic valve implantation (TAVI) system (InFlow, CardValve Consortium, Poland) in an ovine model of aortic banding. METHODS: Surgical ascending aorta banding was created in 21 sheep. Two weeks later, 18 biological valves were implanted within the model using 15-16 F InFlow TAVI systems and carotid cut-down approach. Follow-up transthoracic echocardiography was performed at 30, 90, and 180-day. At designated time, animals were euthanized and valves harvested for analysis. RESULTS: All sheep survived the banding procedure. There were 4 (22%) procedure related deaths within a 7-day period. During the observation an additional 2 sheep died. In one, the valve dislocated after the procedure - the animal was excluded. Two animals completed 30-day follow up, five 90-day follow-up and four terminal follow-up of 180 days. Valves examined via transesophageal echocardiography showed proper hemodynamic parameters without evidence of structural valve deterioration. The maximum and average flow gradients at 180 days were 31.4 (23.3-37.7) and 17.5 (13.1-20.2) mmHg, respectively. There was one case of moderate insufficiency and no case of perivalvular leaks. By histopathology, there were no inflammation, thrombosis, nor calcifications in any tested valves at long-term follow-up. Neointimal coverage of stent struts increased with time from basal part in "early" groups to nearly 3/4 of stent length in the 180-day group. The pannus tissue showed maturation that increased with time with no stenotic "collar" visible in orthotopically implanted valves. CONCLUSIONS: The study showed good hemodynamic performance, durability and biocompatibility of the novel biological THV.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Animals , Sheep , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prosthesis Design , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
2.
JACC Basic Transl Sci ; 7(5): 486-495, 2022 May.
Article in English | MEDLINE | ID: mdl-35663633

ABSTRACT

The aim of the study was to evaluate a balloon expandable transcatheter heart valve (THV) system (Myval) at 6-month follow-up in ovine banding model. Eleven THV systems were implanted via carotid approach. There were 2 procedure-related deaths and 2 premature deaths. At 6 months all valves that completed follow-up (n = 7) were functional, with no significant regurgitation, calcification, thrombi, or vegetation. Mean pressure gradient was 21.9 ± 11 mm Hg, maximum velocity = 3.3 ± 1 m/s, and ejection fraction was 53.3 ± 6%. Myval THV showed optimal hemodynamic performance and biocompatibility.

3.
Front Cardiovasc Med ; 9: 977006, 2022.
Article in English | MEDLINE | ID: mdl-36606288

ABSTRACT

Objectives: The aim of the study is to evaluate the functionality, durability, and temporal biocompatibility of a novel, balloon-expandable polymeric transcatheter heart valve (ATHV) system (InFlow, CardValve Consortium, Poland). Along with expanding TAVI indications, the demand for new transcatheter valves is increasing. Methods: A surgical ascending aortic banding model was created in 20 sheep. Two weeks later, 16 sheep were implanted with ATHV systems (15-16F). Three animals were euthanized after a 30-day follow-up, four animals after a 90-day follow-up, and six animals after a 180-day follow-up. A follow-up transthoracic echocardiography (TTE) was performed. Results: There was one procedure-related (6,25%) and two model-related deaths (12,5%; banding site calcification with subsequent infection originating externally from banding). TTE revealed the flow gradients (max/average) of 30,75/17,91; 32,57/19,21; and 21,34/10,63 mmHg at 30, 90, and 180 days, respectively. There were two cases of low-degree regurgitation after 180 days with no perivalvular leak observed. Histopathological analysis showed no valve degeneration at terminal follow-up with optimal healing. Small thrombi were present at the aortic wall adjacent to the base of the leaflets, and between the aortic wall and the stent in most of the valves; however, leaflets remained free from thrombi in all cases. Scanty calcifications of leaflets were reported in three animals evaluated 180 days after implantation. Conclusion: This preclinical study in the aortic banding model showed good hemodynamic performance, durability, and biocompatibility of the novel ATHV. Furthermore, regulatory studies with longer follow-ups are warranted.

4.
Postepy Kardiol Interwencyjnej ; 16(1): 76-81, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32368239

ABSTRACT

INTRODUCTION: The rate of atherectomy utilization in peripheral artery diseases (PAD) is growing. The two atherectomy devices available on the market and used most frequently are the directional and rotational ones. Nonetheless, there is a lack of direct comparison between these two types of atherectomy in PAD. AIM: To compare the long-term outcomes after PAD endovascular revascularization with two types of atherectomies: rotational (AR) (Phoenix Philips) and directional (AD) (SilverHawk Medtronic). MATERIAL AND METHODS: This was a single-center, retrospective study of obstructive and symptomatic PAD patients who underwent revascularization with atherectomy. The endpoints were considered as target lesion revascularization (TLR), death, amputations and bailout stenting (BS). RESULTS: The AR group consisted of 97 patients, while the AD group consisted of 85 individuals. There were no significant differences between the groups in terms of baseline characteristics except for an increased critical limb ischemia (CLI) prevalence in the AR group. The mean follow-up for AD and AR was 282.6 ±147.4 and 255.7 ±186.1 days, respectively (p = 0.44). There were no significant differences in the death rate (AD: 1 (1.7%) vs. AR: 5 (5.7%); p = 0.54), amputations (AD: 2 (2.3%) vs. AR: 5 (5.7%); p = 0.45) or bailout stenting (AD: 2 (2.3%) vs. AR: 3 (3.2%); p = 0.74), whereas TLR was more frequent in the AD group (AD: 25 (29%) vs. AR: 15 (15.9%; p = 0.03). The Kaplan-Meier analysis showed no significant differences between the groups in time to TLR, amputation or death. CONCLUSIONS: In this hypothesis-generating study the AR had a lower rate of TLR when compared to the AD. Nevertheless, this should be confirmed in further controlled randomized trials.

5.
Cardiol J ; 27(5): 600-607, 2020.
Article in English | MEDLINE | ID: mdl-30394507

ABSTRACT

BACKGROUND: The prevalence of diabetes has increased significantly in well-developed countries during the last decade and it continues to grow. Diabetes increases the risk of restenosis in patients treated percutaneously for peripheral artery disease. The present study sought to compare outcomes of atherectomy treatment in diabetic (DM) vs. non-diabetic (nDM) patients suffering from peripheral artery disease. METHOD: Between 2008 and 2012, 204 revascularization atherectomy procedures were performed on arteries of the lower extremities. The endpoints included target lesion revascularization (TLR), amputation and death. The type of atherectomy (excisional-soft plaque, orbital-calcified plaque, with active aspiration - with a thrombus) was left to operator discretion. RESULTS: This study contains 132 DM (66% male, age 68 ± 11.2 years) and 72 nDM (63% male, age 75 ± 11.3 years) subjects. DM were younger but had a higher prevalence of coronary artery disease (DM: 91% vs. nDM: 62%, p < 0.0001) and end-stage renal disease (DM: 22% vs. nDM: 2.5%, p < 0.0001). There were no differences in critical limb ischemia between the groups (DM: 21% vs. nDM: 12%, p = = 0.13). Mean time of follow-up was 384 and 411 days in DM and nDM, respectively (p = 0.43). There were no significant differences in TLR (DM: 15.2% vs. nDM: 22.2%, p = 0.249), amputations (DM: 3.0% vs. nDM: 1.5%, p = NS) or death rates (DM: 2.2% vs. nDM: 2.7%, p = NS). Kaplan-Mayer analysis showed no significant differences between the groups in the time to TLR, amputation or death. CONCLUSIONS: Plaque modification with adjusted atherectomy appears to have similar outcomes in diabetic as well as in non-diabetic patients. Nonetheless, a randomized study would be warranted to confirm the findings of the current study.


Subject(s)
Diabetes Mellitus , Peripheral Arterial Disease , Aged , Aged, 80 and over , Amputation, Surgical , Atherectomy , Coronary Artery Disease , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 91(3): 515-520, 2018 02 15.
Article in English | MEDLINE | ID: mdl-28980380

ABSTRACT

OBJECTIVE: The aim of the study was to assess safety and feasibility of one-day early discharge (ODD) after endovascular revascularization (ER) of lower extremities in elderly. BACKGROUND: Safety and feasibility of ODD after ER have never been investigated in the elderly, despite the PAD rate has been rising in well-developed countries as their populations are getting older. METHODS: The consecutive data of 477 patients after ER who were intended to ODD were reviewed. The ER procedure (balloon angioplasty, atherectomy, stenting) was performed due to significant, angiographically confirmed arterial stenosis with at least Rutheford III claudication. The population was divided into two groups: ≥70 years old (y. o.) in which were 235 patients and 220 patients <70 y. o., the younger control cohort. The follow-up was performed 24 hr after (24FU) the procedure and 30 days (30FU) after discharge. RESULTS: There were no differences between the groups in the ratio of same-day discharge (99% vs 99.5%, P = 0.6) and the mean time to ambulation was 287.4 ± 43.4 min versus 285.8 ± 45.7 min (P = 0.603). The ODD was not applied in 2 patients ≥70 y. o. due to two pseudoaneurysms requiring surgical repairs and in one from the control group due to retroperitoneal bleeding. There was no MACE or creatinine increase at 24 hr in both groups. At 30 days, there was no incidence of MACE in the ≥70 y. o. group while 3 MACE occurred in the control. The ratio of access site complications was comparable between the groups. CONCLUSION: The study allows for a hypothesis that the advantages of ODD could be safely extended to the patients ≥70 y. o.


Subject(s)
Endovascular Procedures , Intermittent Claudication/surgery , Length of Stay , Lower Extremity/blood supply , Patient Discharge , Peripheral Arterial Disease/surgery , Adult , Age Factors , Aged , Aged, 80 and over , Angioplasty, Balloon , Atherectomy , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Feasibility Studies , Female , Humans , Intermittent Claudication/diagnostic imaging , Intermittent Claudication/physiopathology , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Registries , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome
7.
Circ J ; 81(3): 376-382, 2017 Feb 24.
Article in English | MEDLINE | ID: mdl-28090010

ABSTRACT

BACKGROUND: The impact of endovascular revascularization of the lower extremity arteries with atherectomy (AT) compared with percutaneous transluminal angioplasty (PTA) is still unclear. Therefore, the aim of the study was to compare long-term outcomes after percutaneous PTA and AT in patients requiring endovascular revascularization.Methods and Results:This was a single-center, retrospective registry of obstructive and symptomatic PAD patients who underwent endovascular revascularization. PTA was performed in 215 patients, and AT in 204 (Silver Hawk, EV3, n=125; CSI 360°, n=66; Pathway Medical Technologies, n=13). There were no significant between-group differences in baseline characteristics except for increased CAD, dialysis and CLI prevalence in the PTA group. Following propensity score analysis 131 well-matched pairs were included in analysis. Bail-out stenting was more frequent in the reference group (PTA, 6.1% vs. AT, 0%; P=0.004). At 6- and 12-month follow-up there were no differences in TLR between the groups (PTA, 8.3% vs. AT, 5.3%; P=0.47; and PTA, 16.7% vs. AT, 13.7%; P=0.73, respectively). The difference was in favor of AT at 24-month follow-up (PTA, 29.0% vs. AT, 16.7%; P=0.05). No difference was observed in amputation rate (PTA, 0.7% vs AT, 1.5%; P=0.62). On Kaplan-Meier analysis there were no significant differences between groups in time to TLR, amputation or death. CONCLUSIONS: AT was associated with lower risk of TLR, and this should be confirmed in randomized controlled trials.


Subject(s)
Angioplasty, Balloon , Atherectomy , Registries , Aged , Aged, 80 and over , Disease-Free Survival , Female , Follow-Up Studies , Humans , Lower Extremity/surgery , Male , Middle Aged , Retrospective Studies , Survival Rate
8.
Vasc Endovascular Surg ; 51(2): 67-71, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28103752

ABSTRACT

BACKGROUND: This was the first prospective study to assess the safety and efficiency of MynxGrip vascular closure device (VCD) in peripheral interventions with antegrade access. METHODS AND RESULTS: We enrolled 66 consecutive patients from 1 center. All patients were discharged home on the day of procedure and were observed for adverse events at 1 and 30 days of follow-up. No major complications were observed. The rate of minor complications (conversion to manual or mechanical compression) was 7.6%. Postdischarge, 3% of patients experienced minor complications-small abscess, ipsilateral deep vein thrombosis. In 1 patient, a second VCD was deployed after device failure. The derived device failure rate was 5.9%. No patients required hospitalization. No late bleeding and no hematomas >6 cm were noted. The mean time to discharge was 4 hours and 5 minutes. CONCLUSION: The MynxGrip was safe and effective in sealing access sites after antegrade femoral artery puncture with same-day discharge.


Subject(s)
Catheterization, Peripheral , Femoral Artery , Hemorrhage/prevention & control , Hemostatic Techniques/instrumentation , Length of Stay , Patient Discharge , Peripheral Arterial Disease/therapy , Vascular Closure Devices , Aged , Catheterization, Peripheral/adverse effects , Equipment Design , Equipment Failure , Female , Femoral Artery/diagnostic imaging , Hemorrhage/etiology , Hemostatic Techniques/adverse effects , Humans , Male , Peripheral Arterial Disease/diagnostic imaging , Poland , Prospective Studies , Punctures , Registries , Time Factors , Treatment Outcome
9.
Cardiol J ; 23(6): 657-666, 2016.
Article in English | MEDLINE | ID: mdl-27976797

ABSTRACT

BACKGROUND: Novel sirolimus eluting stents (SES) have shown non-inferior clinical outcomes when compared to everolimus eluting stents (EES), however only limited preclinical data have been published. Therefore, we evaluate vascular response of a new generation biodegradable polymer SES (BP-SES: Alex Plus, Balton) and fluoropolymer EES (EES: Xience Pro, Abbott) in the porcine coronary restenosis model. METHODS: A total of 40 stents were implanted with 120% overstretch in coronaries of 17 domestic swine: 16 BP-SES, 16 EES and 8 bare metal controls (BMS). Following 28 and 90 days, coronary angiography and optical coherence tomography (OCT) was performed, animals sacrificed and stented segments harvested for pathological evaluation. RESULTS: At 28 days neointimal thickness in OCT was lowest in the BP-SES when compared to EES and BMS (0.18 ± 0.1 vs. 0.39 ± 0.1 vs. 0.34 ± 0.2 mm, respectively; p = 0.04). There was no difference in the proportion of malapposed or uncovered struts, although protruding covered struts were more common in BP-SES (14.8 ± 10% vs. 4.1 ± 4% vs. 3.7 ± 6%; p = 0.03). In pathology, the lowest neointimal thickness was confirmed in BP-SES (p < 0.05). The inflammation score was significantly lower in BP-SES and EES when compared to BMS (0.24 ± 0.1 vs. 0.4 ± 0.1 vs. 0.77 ± 0.4; p < 0.01) whilst EES and BP-SES had higher fibrin scores than BMS (1.2 ± 0.4 vs. 1.3 ± 0.3 vs. 0.17 ± 0.2; p < 0.01). At 90 days neointimal coverage and thickness in OCT was comparable between groups and healing in histopathology was complete. CONCLUSIONS: New generation, BP-SES show similar vascular healing and biocompatibility profile with marginally higher degree of restenosis inhibition, when compared to fluoropolymer EES in the porcine coronary restenosis model.


Subject(s)
Absorbable Implants , Coronary Restenosis/surgery , Drug-Eluting Stents , Everolimus/pharmacology , Percutaneous Coronary Intervention/methods , Polymers , Sirolimus/pharmacology , Animals , Coronary Angiography , Coronary Restenosis/diagnosis , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Disease Models, Animal , Female , Immunosuppressive Agents/pharmacology , Male , Prosthesis Design , Swine , Tomography, Optical Coherence
10.
Catheter Cardiovasc Interv ; 82(3): E155-62, 2013 Sep 01.
Article in English | MEDLINE | ID: mdl-23109067

ABSTRACT

BACKGROUND: The biodegradable polymer drug-eluting stents have been proposed as an alternative to durable polymer DES, theoretically improving vessel healing and reducing the need for prolonged double anti platelet therapy (DAPT), however clinical significance of this technology is under debate. Therefore, we sought to compare the clinical outcomes of two Paclitaxel eluting stents (PES) containing different polymer-based eluting matrices. METHODS: In this multicenter registry of 392 consecutive patients who underwent PCI between June 2006 and September 2008, we included patients with stable angina or NSTE-ACS displaying at least one significant lesion (>50% diameter stenosis) in native coronary arteries. RESULTS: Biodegradable polymer PES (BP-PES, LUC Chopin(2) , Balton, Poland) was implanted in 206 patients, whereas durable polymer PES (DP-PES, Taxus, Boston Scientific, USA) was implanted in 186 patients. There were no significant differences in baseline characteristics between groups with the exception of increased diabetes and number of lesions for BP-PES. In risk-unadjusted analysis at 1-year follow-up, there were no significant differences in TLR (BP-PES: 8.4% vs. DP-PES: 6%; P = 0.36), TVR (BP-PES: 11.1% vs. DP-PES: 8.4%; P = 0.36) and incidence of stent thromboses (BP-PES: 2.15% vs. DP-PES: 3.4%; P = 0.42) between groups. There was also no difference in MACCE between groups (17.6% vs. 14.4%, P = 0.49). The mean dual antiplatelet therapy (DAPT) compliance at 1 year was 77% for BP-PES versus 92% for DP-PES (P = 0.03). Kaplan-Meier analysis showed a significantly higher long-term stroke free survival in BP-PES (P = 0.04). After adjustment, this was sustained with an additional tendency toward higher MI free survival for BP-PES (P = 0.059). CONCLUSIONS: In this observational analysis, BP-PES were comparable to DP-PES, with regard to incidence of repeated revascularizations, stent thromboses and MACCE despite earlier DAPT discontinuation.


Subject(s)
Absorbable Implants , Acute Coronary Syndrome/therapy , Angina, Stable/therapy , Cardiovascular Agents/administration & dosage , Coronary Stenosis/therapy , Drug-Eluting Stents , Paclitaxel/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Platelet Aggregation Inhibitors/administration & dosage , Polymers , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/drug therapy , Acute Coronary Syndrome/mortality , Aged , Angina, Stable/diagnosis , Angina, Stable/drug therapy , Angina, Stable/mortality , Coronary Stenosis/diagnosis , Coronary Stenosis/drug therapy , Coronary Stenosis/mortality , Coronary Thrombosis/mortality , Coronary Thrombosis/prevention & control , Disease-Free Survival , Drug Administration Schedule , Drug Therapy, Combination , Female , Humans , Incidence , Kaplan-Meier Estimate , Male , Medication Adherence , Middle Aged , Myocardial Infarction/mortality , Myocardial Infarction/prevention & control , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Poland/epidemiology , Propensity Score , Prosthesis Design , Registries , Retrospective Studies , Risk Factors , Stroke/mortality , Stroke/prevention & control , Time Factors , Treatment Outcome
11.
Diabetes Care ; 32(8): 1421-4, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19435959

ABSTRACT

OBJECTIVE To compare the effect of short-term metformin and fenofibrate treatment, administered alone or in sequence, on glucose and lipid metabolism, cardiovascular risk factors, and monocyte cytokine release in type 2 diabetic patients with mixed dyslipidemia. RESEARCH DESIGN AND METHODS We studied 128 type 2 diabetic patients with mixed dyslipidemia complying throughout the study with lifestyle intervention who were randomized twice, initially to either metformin or placebo, and then to micronized fenofibrate or placebo. RESULTS Fenofibrate alleviated diabetic dyslipidemia-induced changes in plasma high-sensitivity C-reactive protein, fibrinogen, and plasminogen activator inhibitor (PAI)-1 and in monocyte cytokine release, whereas metformin or lifestyle intervention improved mainly glucose and lipid metabolism. The strongest pleiotropic effect was observed when fenofibrate was added to metformin. CONCLUSIONS Fenofibrate, particularly administered together with metformin, is superior to metformin and lifestyle intervention in exhibiting beneficial effects on systemic inflammation, hemostasis, and monocyte secretory function in type 2 diabetic patients with mixed dyslipidemia.


Subject(s)
Diabetes Mellitus, Type 2/drug therapy , Dyslipidemias/drug therapy , Fenofibrate/therapeutic use , Life Style , Metformin/therapeutic use , Blood Glucose/drug effects , Blood Glucose/metabolism , C-Reactive Protein/metabolism , Cardiovascular Diseases/epidemiology , Combined Modality Therapy , Cytokines/blood , Diabetes Mellitus, Type 2/complications , Diabetic Angiopathies/epidemiology , Double-Blind Method , Drug Therapy, Combination , Dyslipidemias/complications , Fenofibrate/administration & dosage , Fibrinogen/metabolism , Humans , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Hypolipidemic Agents/administration & dosage , Hypolipidemic Agents/therapeutic use , Metformin/administration & dosage , Placebos , Plasminogen Activator Inhibitor 1/blood , Risk Factors
12.
Przegl Lek ; 63(5): 246-8, 2006.
Article in Polish | MEDLINE | ID: mdl-17036497

ABSTRACT

Cardiac pacemaker was implanted as a therapeutic method for children with atrio-ventricular block, sick sinus syndrome, LQT syndrome, cardio-depressive syncope. Twenty six children (aged 1-17) underwent pacemaker implantation or exchange of pacemaker and electrode. In nineteen cases cardiac peacemaker was implanted in the endocardial system; in the next seven cases epicardial system was required. The difference between the implantations depended on patient's age and the character of the disease. The single chamber peacemaker was implanted in twenty children, dual-chamber in six patients. There were no visible complications in follow up observation and constant heart stimulation can be considered as a safe way of children's severe bradycardia treatment.


Subject(s)
Arrhythmias, Cardiac/therapy , Heart Defects, Congenital/surgery , Pacemaker, Artificial , Adolescent , Arrhythmias, Cardiac/complications , Cardiac Pacing, Artificial , Child , Child, Preschool , Electrodes, Implanted , Female , Follow-Up Studies , Heart Defects, Congenital/complications , Humans , Infant , Male , Prognosis , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...