1.
Rev Sci Instrum ; 80(10): 103704, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19895067

ABSTRACT

A high frame rate active pixel sensor designed to track the position of up to six optically trapped objects simultaneously within the field of view of a microscope is described. The sensor comprises 520 x 520 pixels from which a flexible arrangement of six independent regions of interest is accessed at a rate of up to 20 kHz, providing the capability to measure motion in multiple micron scale objects to nanometer accuracy. The combined control of both the sensor and optical traps is performed using unique, dedicated electronics (a field programmable gate array). The ability of the sensor to measure the dynamic position and the forces between six optically trapped spheres, down to femtonewton level, is demonstrated paving the way for application in the physical and life sciences.

2.
Med Phys ; 34(12): 4612-25, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18196789

ABSTRACT

Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525 x 525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25 x 25 microm pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10(5) electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 microm, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at approximately 0.44 microC/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a: Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.


Subject(s)
Empirical Research , Mammography/instrumentation , Metals , Oxides , Adipose Tissue/diagnostic imaging , Breast/cytology , Humans , Lasers , Metals/chemistry , Oxides/chemistry , Phantoms, Imaging , Photons , Radiation Dosage , Transistors, Electronic , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...