J Ultrasound ; 18(3): 265-77, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26261467

ABSTRACT

We report our experience in B-mode ocular ultrasonography, focusing on its contribution when the clinical examination proves to be difficult, mainly due to the existence of intraocular opacities of the ocular fundus or diagnostic doubts. We revise the ocular ultrasound technique, its indications and contraindications, comparing to the other imaging techniques. In our experience ultrasonography revealed pathological findings which confirmed the clinical suspicion in most of cases or provide additional information. With understanding of the indications for ultrasonography and proper examination technique, one can gather a vast amount of information not possible with clinical examination alone.