Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 77
Filter
1.
Am J Prev Cardiol ; 18: 100680, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38764778

ABSTRACT

Objectives: To determine the relationship between lipoprotein particle size/number with hepatic steatosis (HS), given its association with traditional lipoproteins and coronary atherosclerosis. Methods: Individuals with available CT data and blood samples enrolled in the PROMISE trial were studied. HS was defined based on CT attenuation. Lipoprotein particle size/number were measured by nuclear magnetic resonance spectroscopy. Principal components analysis (PCA) was used for dimensionality reduction. The association of PCA factors and individual lipoprotein particle size/number with HS were assessed in multivariable regression models. Associations were validated in an independent cohort of 59 individuals with histopathology defined HS. Results: Individuals with HS (n=410/1,509) vs those without (n=1,099/1,509), were younger (59±8 vs 61±8 years) and less often females (47.6 % vs 55.9 %). All PCA factors were associated with HS: factor 1 (OR:1.36, 95 %CI:1.21-1.53), factor 3 (OR:1.75, 95 %CI:1.53-2.02) and factor 4 (OR:1.49; 95 %CI:1.32-1.68) were weighted heavily with small low density lipoprotein (LDL) and triglyceride-rich (TRL) particles, while factor 2 (OR:0.86, 95 %CI:0.77-0.97) and factor 5 (OR:0.74, 95 %CI:0.65-0.84) were heavily loaded with high density lipoprotein (HDL) and larger LDL particles. These observations were confirmed with the analysis of individual lipoprotein particles in PROMISE. In the validation cohort, association between HS and large TRL (OR: 8.16, 95 %CI:1.82-61.98), and mean sizes of TRL- (OR: 2.82, 95 %CI:1.14-9.29) and HDL (OR:0.35, 95 %CI:0.13-0.72) were confirmed. Conclusions: Large TRL, mean sizes of TRL-, and HDL were associated with radiographic and histopathologic HS. The use of lipoprotein particle size/number could improve cardiovascular risk assessment in HS.

2.
Invest Ophthalmol Vis Sci ; 65(3): 20, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38470325

ABSTRACT

Purpose: The purpose of this study was to investigate rod photopigment bleaching-driven intrinsic optical signals (IOS) in the human outer retina and its measurement repeatability based on a commercial optical coherence tomography (OCT) platform. Methods: The optical path length of the rod photoreceptor subretinal space (SRS), that is, the distance between signal bands of rod outer segment tips and retinal pigment epithelium, was measured in 15 healthy subjects in ambient light and during a long-duration bleaching white-light exposure. Results: On 2 identical study days (day 1 and day 2 [D1 and D2]), light stimulation resulted in a significant decrease in rod SRS by 21.3 ± 7.6% and 19.8 ± 8.5% (both P < 0.001), respectively. The test-retest reliability of the SRS maximum change of an individual subject was moderate for single measures (intraclass correlation coefficient [ICC] = 0.730, 95% confidence interval [CI] = 0.376, 0.900, P < 0.001) and good for average measures (ICC = 0.844, 95% CI = 0.546, 0.947, P < 0.001). The mean area under the stimulus response curve with values of 14.8 ± 9.4 and 15.5 ± 7.5 µm × minutes (P = 0.782) showed excellent agreement between the stimulus response on D1 and D2. Intermittent dark adaptation of the retina led to an initial increase of the SRS by 6.1% (P = 0.018) and thereafter showed a decrease toward baseline, despite continued dark adaptation. Conclusions: The data indicate the potential of commercial OCT in measuring slow IOS in the outer retina suggesting that the rod SRS could serve as a biomarker for photoreceptor function. The presented approach could provide an easily implementable clinical tool for the early detection of diseases affecting photoreceptor health.


Subject(s)
Retina , Tomography, Optical Coherence , Humans , Reproducibility of Results , Retina/diagnostic imaging , Dark Adaptation , Rod Cell Outer Segment
3.
J Thorac Cardiovasc Surg ; 166(6): 1635-1643.e1, 2023 12.
Article in English | MEDLINE | ID: mdl-37263524

ABSTRACT

OBJECTIVES: Biological composite valve grafts (CVGs) are being performed more frequently, which increases the need for interventions treating bioprosthetic valve failure. The feasibility of valve-in-valve procedures in this population is uncertain. This study aimed to assess changes in aortic root geometry and coronary height following CVG implantation to better understand future interventions. METHODS: We retrospectively identified 64 patients following bioprosthetic CVG replacement with pre- and postoperative computed tomography angiography. Root assessment was conducted as in preprocedural transcatheter aortic valve evaluation using a virtual valve simulation. RESULTS: In 64 patients (age, 67.6 ± 9.3 years; 76.6% men) the preoperative coronary height was 14.3 ± 6.8 mm for the left coronary artery (LCA) and 17.9 ± 5.9 mm for the right coronary artery (RCA), which significantly decreased after CVG implantation, with 8.7 ± 4.4 mm for the LCA and 11.3 ± 4.4 mm for the RCA (P < .001). The virtual valve-to-coronary distances measured 4.0 ± 1.3 mm (LCA) and 4.6 ± 1.4 mm (RCA). Overall, 59.4% (n = 38) of patients with bio-CVGs would have been at risk for coronary obstruction, 29.7% (n = 19) for LCA, 10.9% (n = 7) for RCA, and 18.8% (n = 12) for combined LCA and RCA. CONCLUSIONS: Coronary height significantly decreased following CVG implantation. The majority of patients after bio-CVG were at a potential risk for coronary obstruction in future valve-in-valve procedures. Further studies are needed to identify the best possible technique for coronary reimplantation and other measures to diminish the risk for future coronary obstruction in this population.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Middle Aged , Aged , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aorta, Thoracic/surgery , Retrospective Studies , Aorta/surgery , Heart Valve Prosthesis Implantation/adverse effects , Coronary Occlusion/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve Stenosis/surgery
4.
Hepatol Commun ; 6(12): 3406-3420, 2022 12.
Article in English | MEDLINE | ID: mdl-36281983

ABSTRACT

Cardiovascular disease (CVD) is the leading cause of mortality in adults with hepatic steatosis (HS). However, risk factors for CVD in HS are unknown. We aimed to identify factors associated with coronary artery disease (CAD) and incident major adverse cardiovascular events (MACE) in individuals with HS. We performed a nested cohort study of adults with HS detected on coronary computed tomography in the PROspective Multicenter Imaging Study for Evaluation of chest pain (PROMISE) trial. Obstructive CAD was defined as ≥50% coronary stenosis. MACE included hospitalization for unstable angina, nonfatal myocardial infarction, or all-cause death. Multivariate modeling, adjusted for age, sex, atherosclerotic CVD (ASCVD) risk score and body mass index, identified factors associated with obstructive CAD. Cox regression, adjusted for ASCVD risk score, determined the predictors of MACE. A total of 959 of 3,756 (mean age 59.4 years, 55.0% men) had HS. Obstructive CAD was present in 15.2% (145 of 959). Male sex (adjusted odds ratio [aOR] = 1.83, 95% confidence interval [CI] 1.18-1.2.84; p = 0.007), ASCVD risk score (aOR = 1.05, 95% CI 1.03-1.07; p < 0.001), and n-terminal pro-b-type natriuretic peptide (NT-proBNP; aOR = 1.90, 95% CI 1.38-2.62; p < 0.001) were independently associated with obstructive CAD. In the 25-months median follow-up, MACE occurred in 4.4% (42 of 959). Sedentary lifestyle (adjusted hazard ratio [aHR] = 2.53, 95% CI 1.27-5.03; p = 0.008) and NT-proBNP (aOR = 1.50, 95% CI 1.01-2.25; p = 0.046) independently predicted MACE. Furthermore, the risk of MACE increased by 3% for every 1% increase in ASCVD risk score (aHR = 1.03, 95% CI 1.01-1.05; p = 0.02). Conclusion: In individuals with HS, male sex, NT-pro-BNP, and ASCVD risk score are associated with obstructive CAD. Furthermore, ASCVD, NT-proBNP, and sedentary lifestyle are independent predictors of MACE. These factors, with further validation, may help risk-stratify adults with HS for incident CAD and MACE.


Subject(s)
Cardiovascular Diseases , Coronary Artery Disease , Humans , Male , Middle Aged , Female , Coronary Angiography/methods , Cardiovascular Diseases/epidemiology , Cohort Studies , Prospective Studies , Coronary Artery Disease/epidemiology , Risk Factors , Heart Disease Risk Factors
5.
JACC Cardiovasc Imaging ; 15(8): 1427-1438, 2022 08.
Article in English | MEDLINE | ID: mdl-35926901

ABSTRACT

BACKGROUND: Increased inflammation and myocardial injury can be observed in the absence of myocardial infarction or obstructive coronary artery disease (CAD). OBJECTIVES: The authors determined whether biomarkers of inflammation and myocardial injury-interleukin (IL)-6 and high-sensitivity cardiac troponin (hs-cTn)-were associated with the presence and extent of CAD and were independent predictors of major adverse cardiovascular events (MACEs) in stable chest pain. METHODS: Using participants from the PROMISE trial, the authors measured hs-cTn I and IL-6 concentrations and analyzed computed tomography angiography (CTA) images in the core laboratory for CAD characteristics: significant stenosis (≥70%), high-risk plaque (HRP), Coronary Artery Disease Reporting and Data System (CAD-RADS) categories, segment involvement score (SIS), and coronary artery calcium (CAC) score. The primary endpoint was a composite MACE (death, myocardial infarction, or unstable angina). RESULTS: The authors included 1,796 participants (age 60.2 ± 8.0 years; 47.5% men, median follow-up 25 months). In multivariable linear regression adjusted for atherosclerotic cardiovascular disease (ASCVD) risk, hs-cTn was associated with HRP, stenosis, CAD-RADS, and SIS. IL-6 was only associated with stenosis and CAD-RADS. hs-cTn above median (1.5 ng/L) was associated with MACEs in univariable analysis (HR: 2.1 [95% CI: 1.3-3.6]; P = 0.006), but not in multivariable analysis adjusted for ASCVD and CAD. IL-6 above median (1.8 ng/L) was associated with MACEs in multivariable analysis adjusted for ASCVD and HRP (HR: 1.9 [95% CI: 1.1-3.3]; P = 0.03), CAC (HR: 1.9 [95% CI: 1.0-3.4]; P = 0.04), and SIS (HR: 1.8 [95% CI: 1.0-3.2]; P = 0.04), but not for stenosis or CAD-RADS. In participants with nonobstructive CAD (stenosis 1%-69%), the presence of both hs-cTn and IL-6 above median was strongly associated with MACEs (HR: 2.5-2.7 after adjustment for CAD characteristics). CONCLUSIONS: Concentrations of hs-cTn and IL-6 were associated with CAD characteristics and MACEs, indicating that myocardial injury and inflammation may each contribute to pathways in CAD pathophysiology. This association was most pronounced among participants with nonobstructive CAD representing an opportunity to tailor treatment in this at-risk group. (PROspective Multicenter Imaging Study for Evaluation of Chest Pain [PROMISE]; NCT01174550).


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Myocardial Infarction , Plaque, Atherosclerotic , Aged , Chest Pain , Constriction, Pathologic/complications , Coronary Angiography/methods , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/complications , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Female , Humans , Inflammation/complications , Interleukin-6 , Male , Middle Aged , Myocardial Infarction/complications , Predictive Value of Tests , Prognosis , Prospective Studies , Risk Assessment , Risk Factors , Troponin , Troponin I
6.
Vascular ; 30(5): 856-858, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34256612

ABSTRACT

BACKGROUND/OBJECTIVE: To evaluate the safety and utility of a new in Europe intravascular ultrasound (IVUS) catheter in a case of peripheral arterial disease caused by in-stent restenosis of the superficial femoral artery. METHOD: Pre-therapeutic computed tomographic angiography identified severe stent restenosis related to device underexpansion, which was caused by an underlying eccentric severely calcified stenosis leading to suboptimal device deployment. The OptiCross 18 (30 MHz Peripheral Imaging Catheter, Boston Scientific, USA) is a short rail imaging catheter. It consists of two main assemblies: The imaging core is composed of a hi-torque, flexible, rotating drive cable with a radial looking 30 MHz ultrasonic transducer at the distal tip. An electro-mechanical connector interface at the proximal end of the catheter makes the connection to the Motordrive Unit (MDU5 PLUSTM) Instrument. The MDU5 PLUS-catheter interface consists of an integrated mechanical drive socket and electrical connection. RESULTS: The use of the IVUS-guided imaging revealed in-stent restenosis, fracture, and protrusion of the calcified plaque in the stent and confirmed the preoperative computed tomography angiography which showed stent compression. Use of intravascular litotripsy catheter (intravascular lithotripsy Shockwave Medical, Santa Clara, California) and drug coated balloon led to improvement in stent expansion, having minimal patent diameter of 5.77 mm. The patient's subsequent clinical course was uneventful, and clinically had palpable pulses in the foot and ankle-brachial index of 1. CONCLUSIONS: Whether acoustic pulse application might affect device structure in the long term remains to be determined, use of the novel IVUS system demonstrated excellent visibility of the etiology of the in-stent restenosis improving the perioperative diagnostic modalities of suboptimal endovascular outcome.


Subject(s)
Coronary Restenosis , Lithotripsy , Constriction, Pathologic , Coronary Restenosis/diagnosis , Femoral Artery/diagnostic imaging , Humans , Lithotripsy/adverse effects , Stents , Ultrasonography, Interventional
7.
J Endovasc Ther ; 29(2): 226-239, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34605299

ABSTRACT

PURPOSE: Chimney endovascular abdominal aortic aneurysm repair (CHEVAR) has predominantly been described as an alternative technique for the management of urgent presentations of degenerative pararenal aortic aneurysms (dPAAs). However, the role of CHEVAR in the treatment of asymptomatic patients remains unknown. The aim of current multinational study was to evaluate the outcomes of elective CHEVAR of dPAAs. MATERIAL AND METHODS: Retrospective analysis of 267 consecutive dPAA patients treated with elective CHEVAR at 13 European and US centers from 2008 to 2014. Primary endpoints were 30 days and out of hospital CHEVAR-related mortality. Secondary endpoints included persistent type Ia endoleak or endotension, angiographically confirmed occlusion and/or high-grade chimney graft (CG) or involved splanchnic vessel stenosis identified at index procedure and/or during follow-up, as well as CHEVAR-related re-intervention. RESULTS: Mean follow-up time was 25.5±13.3 months. The 442 visceral vessels were involved and mean number of CGs per patient was 1.63±0.7. 436 targeted vessels were successfully cannulated. The aortic graft intentionally covered 6 renal arteries and immediate technical success was 98.6%. The 30 days mortality was 1.9% (n=5), while the in-hospital complication rate was 10.1% (n=27) including 3 strokes, 1 permanent dialysis, and 1 intestinal ischemia. No 30 day type Ia endoleaks were detected and 3.2% of CGs (n=14, including the intentionally covered) had evidence of occlusion and/or stenosis. The overall CHEVAR-related mortality was 2.2% (n=6). Freedom from primary and secondary type Ia endoleak/endotension rates at 3 years was 93.0% and 98.0%, respectively. Primary and secondary CG patency was 87.0% and 89.0%. Primary and secondary endovascular freedom from any endpoint at 3 years was 81.0% and 94.0% respectively. CONCLUSION: Elective use of CHEVAR in the management of dPAAs seems to be durable. These results are comparable to published outcomes with other total endovascular strategies, which justifies an expanded role for CHEVAR in the treatment of asymptomatic patients presenting with dPAAs.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Humans , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Treatment Outcome
8.
Ann N Y Acad Sci ; 1510(1): 145-157, 2022 04.
Article in English | MEDLINE | ID: mdl-34893981

ABSTRACT

Intrinsic optical signals constitute a noninvasive biomarker promising the objective assessment of retinal photoreceptor function. We employed a commercial optical coherence tomography (OCT) system and an OCT signal model for evaluation of optical path length (OPL) changes in the temporal outer retina of five healthy subjects during light adaptation. Data were acquired at 30 time points, in ambient light and during long duration stimulation with white light, and analyzed, employing a signal model based on the sum of seven Gaussian curves corresponding to all relevant anatomical structures of the outer retina. During light stimulation, mean OPL between rod outer segment tips (ROST) and the retinal pigment epithelium (RPE) decreased by 21.4 ± 3.5%. Further, OPL between the external-limiting membrane (ELM) and the RPE decreased by 5.2 ± 0.9% versus baseline, while OPL between ELM and ROST showed an initial decrease by 2.1 ± 1.6% versus baseline and, thereafter, increased by 2.8 ± 2.1% versus baseline. Thus, the presented approach allowed for assess to dynamic changes in the outer retina in response to light. The change in the subretinal space occurring in the context of light adaptation could be measured using a standard OCT platform and a dedicated signal model.


Subject(s)
Retina , Tomography, Optical Coherence , Humans , Retina/diagnostic imaging , Retina/physiology , Retinal Pigment Epithelium/diagnostic imaging , Tomography, Optical Coherence/methods
9.
JAMA Cardiol ; 7(3): 259-267, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-34935857

ABSTRACT

IMPORTANCE: Race and ethnicity have been studied as risk factors in cardiovascular disease. How risk factors, epicardial coronary artery disease, and cardiac events differ between Black and White individuals undergoing noninvasive testing for coronary artery disease is not known. OBJECTIVE: To assess differences in cardiovascular risk burden, coronary plaque, and major adverse cardiac events between Black and White individuals assigned to receive coronary computed tomography angiography (CCTA) or functional testing for stable chest pain. DESIGN, SETTING, AND PARTICIPANTS: A nested observational cohort study within the PROMISE trial was conducted at 193 outpatient sites in North America. A total of 1071 non-Hispanic Black (hereafter Black) and 7693 non-Hispanic White (hereafter White) participants with stable chest pain undergoing noninvasive cardiovascular testing were included. This analysis was conducted from February 13, 2015, to November 2, 2021. MAIN OUTCOMES AND MEASURES: The primary end point was the composite of death, myocardial infarction, or hospitalization for unstable angina over a median follow-up of 24.4 months. RESULTS: Among 1071 Black individuals (12.2%) (women, 646 [60.3%]; mean [SD] age, 59 [8] years) and 7693 White individuals (87.8%) (women, 4029 [52.4%]; mean [SD] age, 61.1 [8.4] years), Black participants had a higher cardiovascular risk burden (more hypertension and diabetes), yet there was a similarly low major adverse cardiovascular events rate over a median 2-year follow-up (32 [3.0%] vs 243 [3.2%]; P = .84). Sensitivity analyses restricted to the 79.8% (6993 of 8764) individuals with a normal or mildly abnormal noninvasive testing result and the 54.3% (4559 of 8396) not receiving statin therapy yielded similar findings. In comparison of Black and White individuals in the CCTA group (n = 3323), significant coronary stenosis (hazard ratio [HR], 7.21; 95% CI, 1.94-26.76 vs HR, 4.30; 95% CI, 2.62-7.04) and high-risk plaque (HR, 3.47; 95% CI, 1.00-12.06 vs HR, 2.21; 95% CI, 1.37-3.57) were associated with major adverse cardiovascular events in both Black and White patients. However, with respect to epicardial coronary artery disease burden, Black individuals had a less-prevalent coronary artery calcium score greater than 0 (45.1% vs 63.2%; P < .001), coronary stenosis greater than or equal to 50% (32 [8.7%] vs 430 [14.6%]; P = .001), and high-risk plaque (139 [37.6%] vs 1547 [52.4%]; P < .001). CONCLUSIONS AND RELEVANCE: The findings of this study suggest that, despite a greater cardiovascular risk burden in Black persons, rates of coronary artery calcium, stenosis, and high-risk plaque observed via CCTA were lower in Black persons than White persons. This result suggests differences in cardiovascular risk burden and coronary plaque in Black and White individuals with stable chest pain.


Subject(s)
Cardiovascular Diseases , Coronary Artery Disease , Coronary Stenosis , Plaque, Atherosclerotic , Calcium , Cardiovascular Diseases/complications , Cardiovascular Diseases/epidemiology , Chest Pain/etiology , Coronary Angiography/methods , Coronary Artery Disease/complications , Coronary Artery Disease/epidemiology , Coronary Stenosis/complications , Female , Heart Disease Risk Factors , Humans , Middle Aged , Plaque, Atherosclerotic/complications , Risk Factors
10.
JACC Cardiovasc Imaging ; 14(11): 2186-2195, 2021 11.
Article in English | MEDLINE | ID: mdl-33865792

ABSTRACT

OBJECTIVES: The purpose of this study was to develop a risk prediction model for patients with nonobstructive CAD. BACKGROUND: Among stable chest pain patients, most cardiovascular (CV) events occur in those with nonobstructive coronary artery disease (CAD). Thus, developing tailored risk prediction approaches in this group of patients, including CV risk factors and CAD characteristics, is needed. METHODS: In PROMISE (Prospective Multicenter Imaging Study for Evaluation of Chest Pain) computed tomographic angiography patients, a core laboratory assessed prevalence of CAD (nonobstructive 1% to 49% left main or 1% to 69% stenosis any coronary artery), degree of stenosis (minimal: 1% to 29%; mild: 30% to 49%; or moderate: 50% to 69%), high-risk plaque (HRP) features (positive remodeling, low-attenuation plaque, and napkin-ring sign), segment involvement score (SIS), and coronary artery calcium (CAC). The primary end point was an adjudicated composite of unstable angina pectoris, nonfatal myocardial infarction, and death. Cox regression analysis determined independent predictors in nonobstructive CAD. RESULTS: Of 2,890 patients (age 61.7 years, 46% women) with any CAD, 90.4% (n = 2,614) had nonobstructive CAD (mean age 61.6 yrs, 46% women, atherosclerotic cardiovascular disease [ASCVD] risk 16.2%). Composite events were independently predicted by ASCVD risk (hazard ratio [HR]: 1.03; p = 0.001), degree of stenosis (30% to 69%; HR: 1.91; p = 0.011), and presence of ≥2 HRP features (HR: 2.40; p = 0.008). Addition of ≥2 HRP features to: 1) ASCVD and CAC; 2) ASCVD and SIS; or 3) ASCVD and degree of stenosis resulted in a statistically significant improvement in model fit (p = 0.0036; p = 0.0176; and p = 0.0318; respectively). Patients with ASCVD ≥7.5%, any HRP, and mild/moderate stenosis had significantly higher event rates than those who did not meet those criteria (3.0% vs. 6.2%; p = 0.007). CONCLUSIONS: Advanced coronary plaque features have incremental value over total plaque burden for the discrimination of clinical events in low-risk stable chest pain patients with nonobstructive CAD. This may be a first step to improve prevention in this cohort with the highest absolute risk for CV events.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Computed Tomography Angiography , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/epidemiology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Risk Assessment/methods , Risk Factors
11.
Diabetes Care ; 44(4): 1038-1045, 2021 04.
Article in English | MEDLINE | ID: mdl-33558267

ABSTRACT

OBJECTIVE: Obesity and metabolic syndrome are associated with major adverse cardiovascular events (MACE). However, whether distinct metabolic phenotypes differ in risk for coronary artery disease (CAD) and MACE is unknown. We sought to determine the association of distinct metabolic phenotypes with CAD and MACE. RESEARCH DESIGN AND METHODS: We included patients from the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE) who underwent coronary computed tomography (CT) angiography. Obesity was defined as a BMI ≥30 kg/m2 and metabolically healthy as less than or equal to one metabolic syndrome component except diabetes, distinguishing four metabolic phenotypes: metabolically healthy/unhealthy and nonobese/obese (MHN, MHO, MUN, and MUO). Differences in severe calcification (coronary artery calcification [CAC] ≥400), severe CAD (≥70% stenosis), high-risk plaque (HRP), and MACE were assessed using adjusted logistic and Cox regression models. RESULTS: Of 4,381 patients (48.4% male, 60.5 ± 8.1 years of age), 49.4% were metabolically healthy (30.7% MHN and 18.7% MHO) and 50.6% unhealthy (22.3% MUN and 28.4% MUO). MHO had similar coronary CT findings as compared with MHN (severe CAC/CAD and HRP; P > 0.36 for all). Among metabolically unhealthy patients, those with obesity had similar CT findings as compared with nonobese (P > 0.10 for all). However, both MUN and MUO had unfavorable CAD characteristics as compared with MHN (P ≤ 0.017 for all). A total of 130 events occurred during follow-up (median 26 months). Compared with MHN, MUN (hazard ratio [HR] 1.61 [95% CI 1.02-2.53]) but not MHO (HR 1.06 [0.62-1.82]) or MUO (HR 1.06 [0.66-1.72]) had higher risk for MACE. CONCLUSIONS: In patients with stable chest pain, four metabolic phenotypes exhibit distinctly different CAD characteristics and risk for MACE. Individuals who are metabolically unhealthy despite not being obese were at highest risk in our cohort.


Subject(s)
Coronary Artery Disease , Metabolic Syndrome , Chest Pain/epidemiology , Chest Pain/etiology , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Metabolic Syndrome/complications , Metabolic Syndrome/epidemiology , Middle Aged , Phenotype , Prospective Studies , Risk Factors
12.
Eur Radiol ; 31(8): 6200-6210, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33501599

ABSTRACT

OBJECTIVES: The size of the heart may predict major cardiovascular events (MACE) in patients with stable chest pain. We aimed to evaluate the prognostic value of 3D whole heart volume (WHV) derived from non-contrast cardiac computed tomography (CT). METHODS: Among participants randomized to the CT arm of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE), we used deep learning to extract WHV, defined as the volume of the pericardial sac. We compared the WHV across categories of cardiovascular risk factors and coronary artery disease (CAD) characteristics and determined the association of WHV with MACE (all-cause death, myocardial infarction, unstable angina; median follow-up: 26 months). RESULTS: In the 3798 included patients (60.5 ± 8.2 years; 51.5% women), the WHV was 351.9 ± 57.6 cm3/m2. We found smaller WHV in no- or non-obstructive CAD, women, people with diabetes, sedentary lifestyle, and metabolic syndrome. Larger WHV was found in obstructive CAD, men, and increased atherosclerosis cardiovascular disease (ASCVD) risk score (p < 0.05). In a time-to-event analysis, small WHV was associated with over 4.4-fold risk of MACE (HR (per one standard deviation) = 0.221; 95% CI: 0.068-0.721; p = 0.012) independent of ASCVD risk score and CT-derived CAD characteristics. In patients with non-obstructive CAD, but not in those with no- or obstructive CAD, WHV increased the discriminatory capacity of ASCVD and CT-derived CAD characteristics significantly. CONCLUSIONS: Small WHV may represent a novel imaging marker of MACE in stable chest pain. In particular, WHV may improve risk stratification in patients with non-obstructive CAD, a cohort with an unmet need for better risk stratification. KEY POINTS: • Heart volume is easily assessable from non-contrast cardiac computed tomography. • Small heart volume may be an imaging marker of major adverse cardiac events independent and incremental to traditional cardiovascular risk factors and established CT measures of CAD. • Heart volume may improve cardiovascular risk stratification in patients with non-obstructive CAD.


Subject(s)
Cardiac Volume , Coronary Artery Disease , Chest Pain/diagnostic imaging , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Predictive Value of Tests , Prognosis , Prospective Studies , Risk Assessment , Risk Factors
13.
Clin Gastroenterol Hepatol ; 19(7): 1480-1488.e14, 2021 07.
Article in English | MEDLINE | ID: mdl-32707340

ABSTRACT

BACKGROUND & AIMS: Hepatic steatosis has been associated with increased risk of major adverse cardiovascular events (MACE) but it is not clear whether steatosis is independently associated with risk of MACE. We investigated whether steatosis is associated with risk of MACE independently of the presence and extent of baseline coronary artery disease, assessed by comprehensive contrast-enhanced computed tomography angiography (CTA). METHODS: We conducted a nested cohort study of 3756 subjects (mean age, 60.6 years; 48.4% men) who underwent coronary CTA at 193 sites in North America, from July 2010 through September 2013, as part of the PROMISE study, which included noninvasive cardiovascular analyses of symptomatic outpatients without coronary artery disease. Independent core laboratory readers measured hepatic and splenic attenuation, using non-contrast computed tomography images to identify steatosis, and evaluated coronary plaques and stenosis in coronary CTA images. We collected data on participants' cardiovascular risk factors, presence of metabolic syndrome, and body mass index. The primary endpoint was an adjudicated composite of MACE (death, myocardial infarction, or unstable angina) during a median follow-up time of 25 months. RESULTS: Among the 959 subjects who had steatosis (25.5% of the cohort), 42 had MACE (4.4%), whereas among the 2797 subjects without steatosis, 73 had MACE (2.6%) (hazard ratio [HR] for MACE in subjects with steatosis, 1.69; 95% CI, 1.16-2.48; P = .006 for MACE in subjects with vs without steatosis). This association remained after adjustment for atherosclerotic cardiovascular disease risk scores, significant stenosis, and metabolic syndrome (adjusted HR, 1.72; 95% CI, 1.16-2.54; P = .007) or obesity (adjusted HR, 1.75; 95% CI, 1.19-2.59; P = .005). Steatosis remained independently associated with MACE after adjustment for all CTA measures of plaques and stenosis. CONCLUSIONS: Hepatic steatosis is associated with MACE independently of other cardiovascular risk factors or extent of coronary artery disease. Strategies to reduce steatosis might reduce risk of MACE. ClinicalTrials.gov no: NCT01174550.


Subject(s)
Coronary Artery Disease , Cohort Studies , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/epidemiology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Risk Factors
14.
Sci Rep ; 10(1): 13909, 2020 08 17.
Article in English | MEDLINE | ID: mdl-32807858

ABSTRACT

Perioperative stroke is a devastating complication after coronary artery bypass graft (CABG) surgery, with atherosclerosis of the ascending aorta as important risk factor. During surgical manipulation, detachment of plaques can lead to consecutive embolization into brain-supplying arteries. High-pitch computed tomography angiography (HP-CTA) represents a non-invasive imaging modality, which provides the opportunity for comprehensive imaging of the ascending aorta, including plaque detection and advanced characterization. In our present retrospective study on 719 individuals, who had undergone HP-CTA within 6 months prior to CABG, atherosclerotic disease of the ascending aorta was evaluated with respect to perioperative stroke rates. For image analysis, the ascending aorta was divided into a proximal and distal part, consisting of four segments, and evaluated for presence and distribution of calcified and mixed plaques. All patients with perioperative stroke presented with atherosclerotic disease of the ascending aorta. The stroke rate was significantly associated with the presence and extent of atherosclerotic disease. Patients burdened with mixed plaques presented with significantly higher perioperative stroke rates. This study demonstrates that HP-CTA allows accurate evaluation of plaque extent and composition in the ascending aorta, and therefore may improve risk stratification of stroke prior to CABG.


Subject(s)
Aorta/diagnostic imaging , Computed Tomography Angiography , Coronary Artery Bypass/adverse effects , Plaque, Atherosclerotic/diagnostic imaging , Stroke/etiology , Aged , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Perioperative Care
15.
Transl Vis Sci Technol ; 9(7): 34, 2020 06.
Article in English | MEDLINE | ID: mdl-32832239

ABSTRACT

Purpose: To investigate the repeatability and reproducibility of total retinal blood flow measurements using a custom-built dual-beam bidirectional Doppler optical coherence tomography (OCT) system in healthy subjects. Methods: Repeatability and reproducibility were analyzed in 10 and 34 healthy subjects, respectively. For repeatability, measurements were taken twice within 30 minutes, for reproducibility, twice within two to five weeks. Two analysis approaches were compared for calculation of absolute blood velocities: a previously published approach resulting in values for total arterial (QA,abs) and total venous blood flow (QV,abs) and a novel approach taking into account that there is a fixed relation between the phase shift in the two OCT channels (QA,new, QV,new). Repeatability and reproducibility were quantified using intraclass correlation coefficients (ICCs). Results: For QA,abs and QV,abs, ICC values between 0.78 and 0.84 were obtained. QA,new and QV,new values revealed better repeatability and reproducibility as compared to the convential appoach. Repeatability ICCs for QA,new and QV,new were between 0.91 and 0.93, and reproducibility ICCs were between 0.87 and 0.91 indicating excellent reproducibility. Good agreement was observed between total retinal blood flow values as measured from retinal arteries and retinal veins. Conclusions: Measurement of total retinal blood flow using dual-beam Doppler OCT shows excellent reproducibility, which can further be improved by using a novel algorithm for calculating blood velocities in retinal vessels. Translational Relevance: Our data indicate that dual-beam Doppler OCT can be used for longitudinal studies. Hence, quantitative retinal blood flow may be established as a biomarker for progression vascular eye diseases.


Subject(s)
Retinal Vessels , Tomography, Optical Coherence , Fourier Analysis , Humans , Regional Blood Flow , Reproducibility of Results , Retinal Vessels/diagnostic imaging
17.
Mol Vis ; 26: 326-333, 2020.
Article in English | MEDLINE | ID: mdl-32355442

ABSTRACT

Purpose: The aim of the present study was to investigate the effect of a three-month dietary supplementation with a methylfolate formulation on homocysteine plasma concentrations and ocular blood flow parameters in patients with diabetes. Methods: Twenty-four patients with diabetes received a dietary supplement (Oculofolin, Aprofol AG, Switzerland) containing 900 µg L­methylfolate (levomefolate calcium or [6S]-5-methyltetrahydrofolic acid, calcium salt), methylcobalamin, and other ingredients for three consecutive months. The patients' plasma homocysteine concentration and retinal blood flow were assessed at baseline and after three months of folate intake. Retinal blood flow was measured using a custom-built dual-beam Doppler optical coherence tomography (OCT) system. In addition, flicker-induced retinal vasodilatation was assessed by means of a commercially available dynamic vessel analyzer (IMEDOS, Jena, Germany). Results: Supplementation was well tolerated by all patients. After three months, plasma homocysteine concentration significantly decreased from 14.2 ± 9.3 to 9.6 ± 6.6 µmol/L (p < 0.001). In addition, a tendency toward an increased total retinal blood flow from 36.8 ± 12.9 to 39.2 ± 10.8 µl/min was observed, but this effect did not reach the level of significance (p = 0.11). Supplementation had no effect on retinal vessel diameter or flicker-induced vasodilatation. Conclusions: The present data show that a three-month intake of a dietary supplement containing methylfolate can significantly reduce blood homocysteine levels in patients with diabetes. This is of importance because higher homocysteine plasma levels have been found to be associated with an increased risk of vascular associated systemic diseases and eye diseases. Whether systemic methylfolate supplementation affects retinal perfusion must be studied in a larger population.


Subject(s)
Blood Circulation/drug effects , Diabetes Mellitus/blood , Homocysteine/blood , Retina/drug effects , Retinal Vessels/drug effects , Tetrahydrofolates/administration & dosage , Vitamins/administration & dosage , Adolescent , Adult , Aged , Diabetes Mellitus/diet therapy , Dietary Supplements , Female , Humans , Male , Middle Aged , Pilot Projects , Retina/metabolism , Retinal Vessels/physiology , Tetrahydrofolates/blood , Tomography, Optical Coherence , Vitamin B 12/administration & dosage , Vitamin B 12/analogs & derivatives
18.
Invest Ophthalmol Vis Sci ; 61(2): 33, 2020 02 07.
Article in English | MEDLINE | ID: mdl-32084274

ABSTRACT

Purpose: Blood flow autoregulation is an intrinsic mechanism of the healthy retinal vasculature to keep blood flow constant when ocular perfusion pressure (OPP) is changed. In the present study, we set out to investigate retinal blood flow in response to an experimental decrease in OPP in healthy participants using Doppler optical coherence tomography. Methods: Fifteen healthy participants aged between 22 and 31 years (mean, 27 ± 3 years) were included in the present open study. IOP was increased stepwise via the suction cup method to induce a decrease in OPP. Retinal blood flow in arteries and veins was assessed using a custom-built Doppler optical coherence tomography system and pressure-flow relationships were calculated to assess autoregulation. Results: Suction cup application induced a pronounced increase in IOP with a maximum value of 50.5 ± 8.0 mm Hg at the highest level of suction. Pressure-flow relationships revealed that blood flow was autoregulated until the OPP was decreased by approximately 21 mm Hg and started to decrease significantly when the OPP was reduced by 30 mm Hg. Retinal blood flow at the last suction period decreased at a maximum of -57.0 ± 22.3% and 65.2 ± 15.4% in retinal arteries and retinal veins, respectively. These changes in retinal blood flow were less pronounced than the decrease in OPP (-75.2 ± 19.2%), indicating retinal autoregulation. Conclusions: The results of the present study confirm that retinal blood flow is autoregulated in response to changes in the OPP. Doppler optical coherence tomography has the potential to become a clinical tool for the investigation of retinal blood flow autoregulation in the future, because of its ability to assess the blood velocities and diameter of the retinal vessels parallel and therefore also their blood flow in absolute values. (Clinicaltrials.gov number NCT03398616).


Subject(s)
Intraocular Pressure/physiology , Regional Blood Flow/physiology , Retina/physiopathology , Retinal Vessels/physiopathology , Tomography, Optical Coherence/methods , Adult , Female , Healthy Volunteers , Humans , Male , Young Adult
19.
Clin Pharmacol Ther ; 108(1): 155-161, 2020 07.
Article in English | MEDLINE | ID: mdl-31977076

ABSTRACT

It has been hypothesized that besides its intraocular pressure (IOP) lowering potential, tetrahydrocannabinol (THC) may also improve ocular hemodynamics. The aim of the present study was to investigate whether single oral administration of dronabinol, a synthetic THC, alters optic nerve head blood flow (ONHBF) and its regulation in healthy subjects. The study was carried out in a randomized, placebo-controlled, double-masked, two-way crossover design in 24 healthy subjects. For each study participant, 2 study days were scheduled, on which they either received capsules containing 5 mg dronabinol or placebo. ONHBF was measured with laser Doppler flowmetry at rest and while the study participants performed isometric exercise for 6 minutes to increase mean arterial blood pressure (MAP). This was repeated 1 hour after drug intake. Ocular perfusion pressure (OPP) was calculated as 2/3MAP-IOP. Dronabinol was well tolerated and no cannabinoid-related psychoactive effects were reported. Neither administration of dronabinol nor placebo had an effect on IOP, MAP, or OPP. In contrast, dronabinol significantly increased ONHBF at rest by 9.5 ± 8.1%, whereas placebo did not show a change in ONHBF (0.3 ± 7.4% vs. baseline, P < 0.001 between study days). Dronabinol did not alter the autoregulatory response of ONHBF to isometric exercise. In conclusion, the present data indicate that low-dose dronabinol increases ONHBF in healthy subjects without affecting IOP, OPP, or inducing psychoactive side effects. In addition, dronabinol does not alter the autoregulatory response of ONHBF to an experimental increase in OPP. Further studies are needed to investigate whether this effect can also be observed in patients with glaucoma.


Subject(s)
Cannabinoid Receptor Agonists/pharmacology , Dronabinol/pharmacology , Intraocular Pressure/drug effects , Optic Disk/drug effects , Administration, Oral , Adult , Blood Pressure/drug effects , Cross-Over Studies , Double-Blind Method , Exercise , Female , Hemodynamics , Humans , Laser-Doppler Flowmetry , Male , Optic Disk/blood supply , Regional Blood Flow/drug effects , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...