Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Clin Med Phys ; 13(2): 3667, 2012 Mar 08.
Article in English | MEDLINE | ID: mdl-22402383

ABSTRACT

A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X-ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The absorbed dose differences with and without the mesh are less than 1%. No metallic artifacts have been observed in radiographic images associated with the mesh, nor significant disturbances in Hounsfield Units. The TiLOOP Bra mesh does not disturb the dosimetry of a typical radiotherapy treatment and its influence in the quality of the CT scan required for planning is negligible.


Subject(s)
Breast Implants , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Radiographic Image Interpretation, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted , Surgical Mesh , Tomography, X-Ray Computed , Breast Neoplasms/pathology , Female , Humans , Phantoms, Imaging , Radiotherapy Dosage
2.
J Contemp Brachytherapy ; 3(1): 32-35, 2011 Mar.
Article in English | MEDLINE | ID: mdl-27877198

ABSTRACT

PURPOSE: The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. MATERIAL AND METHODS: Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in which 2 mm lead slab was located at 3 mm depth; b) radiochromic EBT films, used to verify the Monte Carlo results, positioning the films at 1.5, 3, 5 and 7 mm depth, inside the phantom. Two irradiations, with and without the lead shielding slab, were carried out. RESULTS: The Monte Carlo results showed that due to the backscatter component from the lead, the dose level raised to about 200% with a depth range of 0.5 mm. Under the lead the dose level was enhanced to about 130% with a depth range of 1 mm. Two millimeters of lead reduce the dose under the slab with about 60%. These results agree with film measurements within uncertainties. CONCLUSIONS: In conclusion, the use of 2 mm internal lead shielding in eyelid skin treatments with the Valencia applicators were evaluated using MC methods and EBT film dosimetry. The minimum bolus thickness that was needed above and below the shielding was 0.5 mm and 1 mm respectively, and the shielding reduced the absorbed dose delivered to the ocular globe by about 60%.

SELECTION OF CITATIONS
SEARCH DETAIL
...