Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
Indian J Pathol Microbiol ; 54(4): 764-8, 2011.
Article in English | MEDLINE | ID: mdl-22234106

ABSTRACT

BACKGROUND: The hemoglobincyanide method (HiCN) method for measuring hemoglobin is used extensively worldwide; its advantages are the ready availability of a stable and internationally accepted reference standard calibrator. However, its use may create a problem, as the waste disposal of large volumes of reagent containing cyanide constitutes a potential toxic hazard. AIMS AND OBJECTIVE: As an alternative to drabkin`s method of Hb estimation, we attempted to estimate hemoglobin by other non-cyanide methods: alkaline hematin detergent (AHD-575) using Triton X-100 as lyser and alkaline- borax method using quarternary ammonium detergents as lyser. MATERIALS AND METHODS: The hemoglobin (Hb) results on 200 samples of varying Hb concentrations obtained by these two cyanide free methods were compared with a cyanmethemoglobin method on a colorimeter which is light emitting diode (LED) based. Hemoglobin was also estimated in one hundred blood donors and 25 blood samples of infants and compared by these methods. Statistical analysis used was Pearson`s correlation coefficient. RESULTS: The response of the non cyanide method is linear for serially diluted blood samples over the Hb concentration range from 3 gm/dl -20 gm/dl. The non cyanide methods has a precision of + 0.25 g/dl (coefficient of variation= (2.34%) and is suitable for use with fixed wavelength or with colorimeters at wavelength- 530 nm and 580 nm. Correlation of these two methods was excellent (r=0.98). The evaluation has shown it to be as reliable and reproducible as HiCN for measuring hemoglobin at all concentrations. The reagents used in non cyanide methods are non-biohazardous and did not affect the reliability of data determination and also the cost was less than HiCN method. CONCLUSIONS: Thus, non cyanide methods of Hb estimation offer possibility of safe and quality Hb estimation and should prove useful for routine laboratory use. Non cyanide methods is easily incorporated in hemoglobinometers by using very minute quantities of reagents and test sample; hence, these methods can be used to provide point of care testing in blood banks for hemoglobin (Hb) estimation in blood donors.


Subject(s)
Clinical Laboratory Techniques/methods , Hemoglobins/analysis , Colorimetry/methods , Humans
4.
Indian J Hematol Blood Transfus ; 23(3-4): 99-103, 2007 Dec.
Article in English | MEDLINE | ID: mdl-23100924

ABSTRACT

AIMS: Blood donors are of voluntary and replacement type. All donors, especially voluntary, are considered as slow risk for seropositive status for Hepatitis B and C, HIV and syphilis. The present study endeavors to screen blood donors-a slow risk group and evaluate the resultant data. METHODOLOGY: We screened 23,068 donors serologically over 2 years for the above blood transmissible diseases. Serum alanine aminotranferase (ALT) and bilirubin were evaluated as surrogate markers in hepatitis B and C positive donors. RESULTS: Seroprevalence rates were found to be HIV (1.96 %), syphilis (2.15 %), hepatitis B (1.98 %) and hepatitis C (0.9 %). Majority donors were voluntary (70.37 %) and male (96.2 %). However seroprevalence rates showed no significant difference: voluntary (7.02 %), replacement (6.67 %) male (6.85 %) and female (6.95 %). HCV and HIV showed highest (29.6 %) while HBV and HCV (2.5 %) showed lowest concomitance. Serum ALT and bilirubin were not effective surrogate markers. No demographic or behavioral variable was found as a significant risk factor. CONCLUSION: Thus, all donors need adequate privacy, information, counseling and motivation in order to reduce the seropositive rates in donors. Advent of sensitive tests renders surrogate markers redundant.

5.
Indian J Gastroenterol ; 10(3): 109-10, 1991 Jul.
Article in English | MEDLINE | ID: mdl-1916958

ABSTRACT

Primary esophageal melanoma is a rare tumor. A 35 year old male with primary malignant melanoma of the esophagus is reported. He presented with dysphagia and weight loss. At autopsy a fusiform polypoidal growth was seen in the middle third of the esophagus. Microscopic sections showed a malignant melanoma in an in situ as well as invasive form.


Subject(s)
Esophageal Neoplasms/pathology , Melanoma/pathology , Adult , Humans , Male , Neoplasm Invasiveness
SELECTION OF CITATIONS
SEARCH DETAIL
...