Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomech Eng ; 142(5)2020 05 01.
Article in English | MEDLINE | ID: mdl-31701120

ABSTRACT

The goals of this study are to compare the lumbar spine response variance between the hybrid III, test device for human occupant restraint (THOR), and global human body models consortium simplified 50th percentile (GHBMC M50-OS) finite element models and evaluate the sensitivity of lumbar spine injury metrics to multidirectional acceleration pulses for spaceflight landing conditions. The hybrid III, THOR, and GHBMC models were positioned in a baseline posture within a generic seat with side guards and a five-point restraint system. Thirteen boundary conditions, which were categorized as loading condition variables and environmental variables, were included in the parametric study using a Latin hypercube design of experiments. Each of the three models underwent 455 simulations for a total of 1365 simulations. The hybrid III and THOR models exhibited similar lumbar compression forces. The average lumbar compression force was 45% higher for hybrid III (2.2 ± 1.5 kN) and 51% higher for THOR (2.0 ± 1.6 kN) compared to GHBMC (1.3 ± 0.9 kN). Compared to hybrid III, THOR sustained an average 64% higher lumbar flexion moment and an average 436% higher lumbar extension moment. The GHBMC model sustained much lower bending moments compared to hybrid III and THOR. Regressions revealed that lumbar spine responses were more sensitive to loading condition variables than environmental variables across all models. This study quantified the intermodel lumbar spine response variations and sensitivity between hybrid III, THOR, and GHBMC. Results improve the understanding of lumbar spine response in spaceflight landings.


Subject(s)
Lumbar Vertebrae , Acceleration , Accidents, Traffic , Biomechanical Phenomena , Computer Simulation , Finite Element Analysis , Weight-Bearing
2.
Ann Biomed Eng ; 47(2): 487-511, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30311040

ABSTRACT

A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk exposure. However, these experiments are expensive and time consuming compared to computational simulations of similar impact events. This study aimed to simulate human volunteer biodynamic response to unidirectional accelerative loading. Data from seven experimental studies involving 212 volunteer tests performed at the Air Force Research Laboratory were used to reconstruct 13 unique loading conditions across four different loading directions using finite element human body model (HBM) simulations. Acceleration pulses and boundary conditions from the experimental tests were applied to the Global Human Body Models Consortium (GHBMC) simplified 50th percentile male occupant (M50-OS) using the LS-Dyna finite element solver. Head acceleration, chest acceleration, and seat belt force traces were compared between the experimental and matched simulation signals using correlation and analysis (CORA) software and averaged into a comprehensive response score ranging from 0 to 1 with 1 representing a perfect match. The mean comprehensive response scores were 0.689 ± 0.018 (mean ± 1 standard deviation) in two frontal simulations, 0.683 ± 0.060 in four rear simulations, 0.676 ± 0.043 in five lateral simulations, and 0.774 ± 0.013 in two vertical simulations. The CORA scores for head and chest accelerations in these simulations exceeded mean scores reported in the original development and validation of the GHBMC M50-OS model. Collectively, the CORA scores indicated that the HBM in these boundary conditions closely replicated the kinematics of the human volunteers across all loading directions.


Subject(s)
Acceleration , Gravitation , Models, Biological , Volunteers , Adult , Biomechanical Phenomena , Female , Finite Element Analysis , Humans , Male
3.
J Biomech Eng ; 141(3)2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30383185

ABSTRACT

The use of anthropomorphic test devices (ATDs) for calculating injury risk of occupants in spaceflight scenarios is crucial for ensuring the safety of crewmembers. Finite element (FE) modeling of ATDs reduces cost and time in the design process. The objective of this study was to validate a Hybrid III ATD FE model using a multidirection test matrix for future spaceflight configurations. Twenty-five Hybrid III physical tests were simulated using a 50th percentile male Hybrid III FE model. The sled acceleration pulses were approximately half-sine shaped, and can be described as a combination of peak acceleration and time to reach peak (rise time). The range of peak accelerations was 10-20 G, and the rise times were 30-110 ms. Test directions were frontal (-GX), rear (GX), vertical (GZ), and lateral (GY). Simulation responses were compared to physical tests using the correlation and analysis (CORA) method. Correlations were very good to excellent and the order of best average response by direction was -GX (0.916±0.054), GZ (0.841±0.117), GX (0.792±0.145), and finally GY (0.775±0.078). Qualitative and quantitative results demonstrated the model replicated the physical ATD well and can be used for future spaceflight configuration modeling and simulation.

4.
Stapp Car Crash J ; 62: 415-442, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30609003

ABSTRACT

Computational models of anthropomorphic test devices (ATDs) can be used in crash simulations to quantify the injury risks to occupants in both a cost-effective and time-sensitive manner. The purpose of this study was to validate the performance of a 50th percentile THOR finite element (FE) model against a physical THOR ATD in 11 unique loading scenarios. Physical tests used for validation were performed on a Horizontal Impact Accelerator (HIA) where the peak sled acceleration ranged from 8-20 G and the time to peak acceleration ranged from 40-110 ms. The directions of sled acceleration relative to the THOR model consisted of -GX (frontal impact), +GY (left-sided lateral impact), and +GZ (downward vertical impact) orientations. Simulation responses were compared to physical tests using the CORrelation and Analysis (CORA) method. Using a weighted method, the average response and standard error by direction was +GY (0.83±0.03), -GX (0.80±0.01), and +GZ (0.76±0.03). Qualitative and quantitative results demonstrated the FE model's kinetics and kinematics were sufficiently validated against its counterpart physical model in the tested loading directions.


Subject(s)
Accidents, Traffic , Models, Theoretical , Acceleration , Biomechanical Phenomena , Finite Element Analysis
5.
Accid Anal Prev ; 82: 244-56, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26103438

ABSTRACT

New vehicles are currently being developed to transport humans to space. During the landing phases, crewmembers may be exposed to spinal and frontal loading. To reduce the risk of injuries during these common impact scenarios, the National Aeronautics and Space Administration (NASA) is developing new safety standards for spaceflight. The Test Device for Human Occupant Restraint (THOR) advanced multi-directional anthropomorphic test device (ATD), with the National Highway Traffic Safety Administration modification kit, has been chosen to evaluate occupant spacecraft safety because of its improved biofidelity. NASA tested the THOR ATD at Wright-Patterson Air Force Base (WPAFB) in various impact configurations, including frontal and spinal loading. A computational finite element model (FEM) of the THOR to match these latest modifications was developed in LS-DYNA software. The main goal of this study was to calibrate and validate the THOR FEM for use in future spacecraft safety studies. An optimization-based method was developed to calibrate the material models of the lumbar joints and pelvic flesh. Compression test data were used to calibrate the quasi-static material properties of the pelvic flesh, while whole body THOR ATD kinematic and kinetic responses under spinal and frontal loading conditions were used for dynamic calibration. The performance of the calibrated THOR FEM was evaluated by simulating separate THOR ATD tests with different crash pulses along both spinal and frontal directions. The model response was compared with test data by calculating its correlation score using the CORrelation and Analysis rating system. The biofidelity of the THOR FEM was then evaluated against tests recorded on human volunteers under 3 different frontal and spinal impact pulses. The calibrated THOR FEM responded with high similarity to the THOR ATD in all validation tests. The THOR FEM showed good biofidelity relative to human-volunteer data under spinal loading, but limited biofidelity under frontal loading. This may suggest a need for further improvements in both the THOR ATD and FEM. Overall, results presented in this study provide confidence in the THOR FEM for use in predicting THOR ATD responses for conditions, such as those observed in spacecraft landing, and for use in evaluating THOR ATD biofidelity.


Subject(s)
Safety , Space Flight , Biomechanical Phenomena , Calibration , Finite Element Analysis , Humans , Models, Biological , Reproducibility of Results , Weight-Bearing
6.
Traffic Inj Prev ; 15(8): 844-54, 2014.
Article in English | MEDLINE | ID: mdl-24433158

ABSTRACT

INTRODUCTION/OBJECTIVE: In an effort to continually improve upon the design of the test device for human occupant restraint (THOR) dummy, a series of modifications have recently been applied. The first objective of this study was to update the THOR head-neck finite element (FE) model to the specifications of the latest dummy modifications. The second objective was to develop and apply a new optimization-based methodology to calibrate the FE head-neck model based on experimental test data. The calibrated head-neck model was validated against both frontal and lateral impact test data. Finally, the sensitivities of the model, in terms of head and neck injury criteria, to pretest positioning conditions were evaluated in a frontal crash test simulation. METHODS: The updated parts of the head-neck THOR FE model were remeshed from CAD geometries of the modified parts. In addition, further model modifications were made to improve the effectiveness of the model (e.g., model stability). A novel calibration methodology, which incorporates the CORA (CORelation and Analysis) rating system with an optimization algorithm implemented in Isight software, was developed to improve both kinematic and kinetic responses of the model in various THOR dummy certification and biomechanical response tests. A parametric study was performed to evaluate head and neck injury criteria values in the calibrated head-neck model during a 40 km/h frontal crash test with respect to variation in the THOR model upper body and belt pretest position. RESULTS: Material parameter optimization was shown to greatly improve the updated model response by increasing the average rating score from 0.794 ± 0.073 to 0.964 ± 0.019. The calibrated neck showed the biggest improvement in the pendulum flexion simulation from 0.681 in the original model up to 0.96 in the calibrated model. The fully calibrated model proved to be effective at predicting dummy response in frontal and lateral loading conditions during the validation phase (0.942 average score). Upper body position was shown to have a greater effect on head-neck response than belt position. The pretest positioning variation resulted in a 10 percent maximum change in HIC36 values and 14 percent maximum change in NIJ values. CONCLUSION: The optimization-based calibration methodology was effective as it markedly improved model performance. The calibrated head-neck model demonstrated application in a crash safety analysis, showing slight head-neck injury sensitivity to pretest positioning in a frontal crash impact scenario.


Subject(s)
Accidents, Traffic/statistics & numerical data , Head/physiology , Manikins , Models, Biological , Neck/physiology , Biomechanical Phenomena , Calibration , Equipment Design , Finite Element Analysis , Humans , Male , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...