Clin Transl Radiat Oncol ; 40: 100628, 2023 May.
Article in English | MEDLINE | ID: mdl-37138702

ABSTRACT

Background and purpose: Definitive radiochemotherapy (RCT) for non-small cell lung cancer (NSCLC) in UICC/TNM I-IVA (singular, oligometastatic) is one of the treatment methods with a potentially curative concept. However, tumour respiratory motion during RT requires exact pre-planning. There are various techniques of motion management like creating internal target volume (ITV), gating, inspiration breath-hold and tracking. The primary goal is to cover the PTV with the prescribed dose while at the same time maximizing dose reduction of surrounding normal tissues (organs at risk, OAR). In this study, two standardized online breath-controlled application techniques used alternately in our department are compared with respect to lung and heart dose. Materials and methods: Twenty-four patients who were indicated for thoracic RT received planning CTs in voluntary deep inspiration breath-hold (DIBH) and in free shallow breathing, prospectively gated in expiration (FB-EH). A respiratory gating system by Varian (Real-time Position Management, RPM) was used for monitoring. OAR, GTV, CTV and PTV were contoured on both planning CTs. The PTV margin to the CTV was 5 mm in the axial and 6-8 mm in the cranio-caudal direction. The consistency of the contours was checked by elastic deformation (Varian Eclipse Version 15.5). RT plans were generated and compared in both breathing positions using the same technique, IMRT over fixed irradiation directions or VMAT. The patients were treated in a prospective registry study with the approval of the local ethics committee. Results: The PTV in expiration (FB-EH) was on average significantly smaller than the PTV in inspiration (DIBH): for tumours in the lower lobe (LL) 431.5 vs. 477.6 ml (Wilcoxon test for connected samples; p = 0.004), in the upper lobe (UL) 659.5 vs. 686.8 ml (p = 0.005). The intra-patient comparison of plans in DIBH and FB-EH showed superiority of DIBH for UL-tumours and equality of DIBH and FB-EH for LL-tumours. The dose for OAR in UL-tumours was lower in DIBH than in FB-EH (mean lung dose p = 0.011; lungV20, p = 0.002; mean heart dose p = 0.016). The plans for LL-tumours in FB-EH showed no difference in OAR compared to DIBH (mean lung dose p = 0.683; V20Gy p = 0.33; mean heart dose p = 0.929). The RT setting was controlled online for each fraction and was robustly reproducible in FB-EH. Conclusion: RT plans for treating lung tumours implemented depend on the reproducibility of the DIBH and advantages of the respiratory situation with respect to OAR. The primary tumour localization in UL correlates with advantages of RT in DIBH, compared to FB-EH. For LL-tumours there is no difference between RT in FB-EH and RT in DIBH with respect to heart or lung exposure and therefore, reproducibility is the dominant criterion. FB-EH is recommended as a very robust and efficient technique for LL-tumours.

2.
Phys Med ; 43: 15-24, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29195558

ABSTRACT

PURPOSE: To commission the treatment planning system (TPS) RayStation for proton therapy including beam models for spot scanning and for uniform scanning. METHODS: Tests consist of procedures from ESTRO booklet number 7, the German DIN for constancy checks of TPSs, and extra tests checking the dose perturbation function. The dose distributions within patients were verified in silico by a comparison of 65 clinical treatment plans with the TPS XiO. Dose-volume parameters, dose differences, and three-dimensional gamma-indices serve as measures of similarity. The monthly constancy checks of Raystation have been automatized with a script. RESULTS: The basic functionality of the software complies with ESTRO booklet number 7. For a few features minor enhancements are suggested. The dose distribution in RayStation agrees with the calculation in XiO. This is supported by a gamma-index (3mm/3%) pass rate of >98.9% (median over 59 plans) for the volume within the 20% isodose line and a difference of <0.3% of V95 of the PTV (median over 59 plans). If spot scanning is used together with a range shifter, the dose level calculated by RayStation can be off by a few percent. CONCLUSIONS: RayStation can be used for the creation of clinical proton treatment plans. Compared to XiO RayStation has an improved modelling of the lateral dose fall-off in passively delivered fields. For spot scanning fields with range shifter blocks an empirical adjustment of monitor units is required. The computation of perturbed doses also allows the evaluation of the robustness of a treatment plan.


Subject(s)
Proton Therapy , Radiotherapy Planning, Computer-Assisted/methods , Computer Simulation , Humans , Quality Control
SELECTION OF CITATIONS
SEARCH DETAIL
...