1.
Vasc Health Risk Manag ; 11: 211-7, 2015.
Article in English | MEDLINE | ID: mdl-25848302

ABSTRACT

OBJECTIVE: The objective of this study is to explore the feasibility and efficacy of a new technique for sutureless vascular anastomosis, using glued prosthesis, as a sole anastomosis fixation method in rabbits. METHODS: Ten rabbits were randomly selected to conduct the experiment. Five rabbits underwent direct anastomosis of infrarenal abdominal aorta, with glued prosthesis. In five other rabbits, reconstruction was done by sutured anastomosis. All animals were immediately examined by echo-Doppler for patency of anastomosis. The burst pressure of the glued anastomosis was measured and compared with that of a sutured artery. The animals were euthanized, and tissue samples were taken for histological examination immediately after the experiment. RESULTS: Compared to conventional anastomoses, sutureless vascular anastomoses required shorter time of creation and significantly reduced blood loss (P<5%). There was no significant difference on the average blood flow through the anastomosis between two groups at the end of surgery. All anastomoses with glued prosthesis, examined by echo-Doppler, were patent at the anastomotic site, except one, which was stenosed immediately after surgery. In the control group, except one with stenosis, all conventional anastomoses were patent. Mean burst pressure at the anastomotic site for sutureless anastomoses was lower than in control group. Macroscopically, the BioGlue did not demonstrate any adhesion to the surrounding tissue as it was covered by the vascular prosthesis. Histological examination showed low-grade inflammatory reaction in glued anastomoses versus no inflammatory reaction at the sutured anastomoses. CONCLUSION: This technique may provide a feasible and successful alternative in vascular surgery. However, further long-term studies are necessary to elucidate the break pressure and degree of inflammation at the anastomotic site.


Subject(s)
Aorta, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis , Proteins/pharmacology , Tissue Adhesives/pharmacology , Animals , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/physiopathology , Blood Loss, Surgical , Blood Vessel Prosthesis Implantation/adverse effects , Feasibility Studies , Female , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Male , Models, Animal , Operative Time , Rabbits , Regional Blood Flow , Stress, Mechanical , Time Factors , Ultrasonography, Doppler , Vascular Patency
2.
Ann Surg Innov Res ; 8(1): 8, 2014.
Article in English | MEDLINE | ID: mdl-25493096

ABSTRACT

BACKGROUND: In recent years, several methods and new techniques have been studied and proposed for establishment of sutureless vascular anastomoses, streaming use of sutureless vascular surgery in the future. PRESENTATION OF THE HYPOTHESIS: The new vascular connector (NVC) is a hypothetical design of a vascular device, proposed for creation and maintenance of sutureless vascular anastomosis. Implication of NVC would introduce a new device and technique in establishment of sutureless vascular anastomosis in which surgical approach is minimized and so post-operation disorders. It would eliminate need for suture; shorten clampage and operation time, consequently reducing stress for both, the surgeon and the patient. It enables the creation of vascular anastomosis fast, simple, safe, reliable, with satisfactory patency and stability of anastomosis. TESTING THE HYPOTHESIS: Efficacy of NVC needs to be evaluated in further studies, in order to be confirmed for clinical use. The effectiveness of NVC should be verified firstly in vitro and in vivo tests; and by animal experiments. The likelihood of its negative influence in thrombogenicity should be well evaluated. IMPLICATIONS OF THE HYPOTHESIS: Implication of the new vascular connector (NVC) would be of interest to both patients and the surgeon due to the following main achievements: 1) enables the creation of vascular anastomosis fast and simple, 2) significant shortening of clampage time of blood vessels and operation time-this assumption would be followed by reduced risk of operative and post-operative complications and length of hospital stay or admission to Intensive care unit, 3) safe and reliable, 4) compatible with any blood vessel and standard vascular graft, 5) using the NVC we will reduce in minimum need for replaced blood volume, 6) reduces the cost of treatment. It is anticipated that the NVC would provide shorter operation time and least operative and post-operative complications in creation of sutureless vascular anastomosis.

SELECTION OF CITATIONS
SEARCH DETAIL
...