Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Hazard Mater ; 408: 124411, 2021 04 15.
Article in English | MEDLINE | ID: mdl-33189467

ABSTRACT

As an emerging contaminant in water, antibiotic resistant bacteria are threatening the public health gravely. In this study, sulfidated ZVI was used to activate persulfate, for antibiotic resistant E. coli and antibiotic resistant genes removal. Impressively, 7 log of antibiotic resistant E. coli was inactivated within 30 min, in sulfidated ZVI activated persulfate system (S/Fe = 0.05). Electron paramagnetic resonance and free radical quenching experiments suggested that sulfidation treatment did not change the specie of radicals. SO4•-and HO• were the main reactive oxygen species for the removal of antibiotic resistant E. coli and genes. Investigation on the activation mechanism of persulfate indicated that persulfate decomposition was mainly attributed to heterogeneous activation. More importantly, in-situ characterization (ATR-FTIR) indicated that the main charge transfer complex was formed on the surface of sulfidated ZVI, which would predominantly mediate the generation of SO4•- and HO•. Finally, the proposed system was evaluated in modeling water and secondary effluent. Results revealed that only 2.86 log and 0.84 log of antibiotic resistant E. coli were inactivated in the presence of NOM (10 mg/L) and HCO3- (84 mg/L), respectively. Besides, sulfidated ZVI activated persulfate system could be pH-dependent in actual wastewater treatment.


Subject(s)
Iron , Water Pollutants, Chemical , Anti-Bacterial Agents/pharmacology , Escherichia coli/genetics , Oxidation-Reduction , Oxidative Stress
2.
Int J Artif Organs ; : 391398820909843, 2020 Mar 04.
Article in English | MEDLINE | ID: mdl-32126866

ABSTRACT

INTRODUCTION: Short-term mechanical circulatory support devices provide temporary hemodynamic support in heart failure and are increasingly used to enable recovery or as a bridge to decision. Blood damage with mechanical circulatory support devices is influenced by many factors, including the magnitude and duration of shear stress and obstruction to blood flow. This study aimed to evaluate the effects of the Impella CP® heart pump positioning on hemolysis using in vitro hemolysis testing and computational fluid dynamics modeling. METHODS: The in vitro hemolysis testing was conducted per the recommended Food and Drug Administration and American Society for Testing and Materials guidelines. The bench hemolysis testing and computational fluid dynamics simulation analysis were performed for both normal operating (outlet unobstructed) and outlet-obstructed condition of Impella CP (mimicking outlet on the aortic valve due to improper positioning). RESULTS: The modified index of hemolysis was 2.78 ± 0.69 at normal operating conditions compared to 18.7 ± 7.8 when the Impella CP outlet was obstructed (p = 0.002). Computational fluid dynamics modeling showed about three times increase in exposure time to regions of high shear stress when the Impella CP outlet was obstructed compared to unobstructed condition, thus supporting the experimental observations. CONCLUSION: Based on these results, it is recommended to ensure proper placement of Impella CP via regular monitoring using echocardiographic guidance or other methods to minimize the risk of hemolysis associated with an obstructed outflow.

3.
Article in English | MEDLINE | ID: mdl-29364029

ABSTRACT

Nanotechnology is currently a fast-rising socioeconomic and political knowledge-based technology owing to the unique characteristics of its engineered nanomaterials. This branch of technology is useful for water and wastewater remediation. Many scientists and researchers have been conducting different studies and experiments on the applications of engineered nanomaterials at the local to international level. This review mainly aims to provide a current overview of existing knowledge on engineered nanomaterials and their applications in water and wastewater remediation. Furthermore, the present risks and challenges of nanotechnology are examined.


Subject(s)
Nanostructures/chemistry , Wastewater/chemistry , Water Purification/methods , Chemical Engineering , Nanotechnology , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...