Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Lab Chip ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38787694

ABSTRACT

Point of care testing (POCT) of nucleic acids holds significant importance in the realm of infectious disease prevention and control, as well as the advancement of personalized precision medicine. Nevertheless, conventional nucleic acid testing methods continue to face challenges such as prolonged detection times and dependence on extensive specialized equipment and personnel, rendering them unsuitable for point of care applications. Here, we proposed an innovative active centrifugal microfluidic system (ACMS) for automatic nucleic acid extraction, encompassing modules for active valve control and magnetic control. An on-chip centrifugal puncture valve (PV) was devised based on the elastic tolerance differences between silicone membranes and tinfoils to release pre-embedded liquid reagents on demand. Furthermore, we have utilized the returnable valve (RV) technology to accurately control the retention and release of liquids, leveraging the high elastic tolerance of the silicone membrane. By incorporating an online controllable magnetic valve, we have achieved controlled and rapid aggregation and dispersion of magnetic beads. The final chip encapsulates multiple reagents and magnetic beads necessary for nucleic acid extraction. Upon sample addition and loading into the instrument, automated on-chip sample loading and nucleic acid extraction, purification, and collection can be accomplished within 30 minutes, halving the overall operation time and even increasing the efficiency of pseudovirus extraction by three orders of magnitude. Consequently, real-time fluorescence quantitative PCR amplification has successfully detected multiple targets of the SARS-CoV-2 virus (with an impressive detection limit as low as 10 copies per µL), along with targeted sequencing analysis yielding a conformity rate of 99%.

2.
Anal Chem ; 96(18): 7145-7154, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38656793

ABSTRACT

Immunoassays serve as powerful diagnostic tools for early disease screening, process monitoring, and precision treatment. However, the current methods are limited by high costs, prolonged processing times (>2 h), and operational complexities that hinder their widespread application in point-of-care testing. Here, we propose a novel centrifugo-pneumatic reciprocating flowing coupled with spatial confinement strategy, termed PRCM, for ultrafast multiplexed immunoassay of pathogens on a centrifugal microfluidic platform. Each chip consists of four replicated units; each unit allows simultaneous detection of three targets, thereby facilitating high-throughput parallel analysis of multiple targets. The PRCM platform enables sequential execution of critical steps such as solution mixing, reaction, and drainage by coordinating inherent parameters, including motor rotation speed, rotation direction, and acceleration/deceleration. By integrating centrifugal-mediated pneumatic reciprocating flow with spatial confinement strategies, we significantly reduce the duration of immune binding from 30 to 5 min, enabling completion of the entire testing process within 20 min. As proof of concept, we conducted a simultaneous comparative test on- and off-the-microfluidics using 12 negative and positive clinical samples. The outcomes yielded 100% accuracy in detecting the presence or absence of the SARS-CoV-2 virus, thus highlighting the potential of our PRCM system for multiplexed point-of-care immunoassays.


Subject(s)
COVID-19 , Centrifugation , SARS-CoV-2 , Immunoassay/methods , Immunoassay/instrumentation , SARS-CoV-2/isolation & purification , Centrifugation/instrumentation , COVID-19/diagnosis , COVID-19/virology , Humans , Microfluidic Analytical Techniques/instrumentation , Lab-On-A-Chip Devices
3.
Small ; : e2310206, 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38085133

ABSTRACT

Point-of-care testing (POCT) is experiencing a groundbreaking transformation with microfluidic chips, which offer precise fluid control and manipulation at the microscale. Nevertheless, chip design or operation for existing platforms is rather cumbersome, with some even heavily depending on external drivers or devices, impeding their broader utilization. This study develops a unique programmable gravity self-driven microfluidic chip (PGSMC) capable of simultaneous multi-reagent sequential release, multi-target analysis, and multi-chip operation. All necessary reagents are introduced in a single step, and the process is initiated simply by flipping the PGSMC vertically, eliminating the need for additional steps or devices. Additionally, it demonstrates successful immunoassays in less than 60 min for antinuclear antibodies testing, compared to more than 120 min by traditional methods. Assessment using 25 clinically diagnosed cases showcases remarkable sensitivity (96%), specificity (100%), and accuracy (99%). These outcomes underscored its potential as a promising platform for POCT with high accuracy, speed, and reliability, highlighting its capability for automated fluid control.

4.
J Med Virol ; 95(11): e29215, 2023 11.
Article in English | MEDLINE | ID: mdl-37933907

ABSTRACT

Respiratory tract infections are associated with the most common diseases transmitted among people and remain a huge threat to global public health. Rapid and sensitive diagnosis of causative agents is critical for timely treatment and disease control. Here, we developed a novel method based on recombinase polymerase amplification (RPA) combined with CRISPR-Cas12a to detect three viral pathogens, including SARS-CoV-2, influenza A, and influenza B, which cause similar symptom complexes of flu cold in the respiratory tract. The detection method can be completed within 1 h, which is faster than other standard detection methods, and the limit of detection is approximately 102 copies/µL. Additionally, this detection system is highly specific and there is no cross-reactivity with other common respiratory tract pathogens. Based on this assay, we further developed a more simplified RPA/CRISPR-Cas12a system combined with lateral flow assay on a manual microfluidic chip, which can simultaneously detect these three viruses. This low-cost detection system is rapid and sensitive, which could be applied in the field and resource-limited areas without bulky and expensive instruments, providing powerful tools for the point-of-care diagnostic.


Subject(s)
COVID-19 , Influenza, Human , Orthomyxoviridae , Humans , Recombinases , SARS-CoV-2 , CRISPR-Cas Systems , Nucleotidyltransferases , Nucleic Acid Amplification Techniques
5.
Anal Chem ; 95(33): 12521-12531, 2023 08 22.
Article in English | MEDLINE | ID: mdl-37556853

ABSTRACT

There remains an unmet need for a fully integrated microfluidic platform that can automatically perform multistep and multireagent immunoassays. Here, we proposed a novel online dual-active valve-based centrifugal microfluidic chip, termed DAVM, for fully automatic point-of-care immunoassay. Practically, the puncture valve, one of the dual active valves, is capable of achieving precise, on-demand, sequential release of prestored reagents, while the other valve-reversible active valve enables controlled retention and drainage of the reaction solutions. Thereby, our technology mitigates the challenges of hydrophilic/hydrophobic modifications and unstable valve control performance commonly observed in passive valve controls. As a proof of concept, the indirect enzymatic immunoblotting technique was employed on DAVM for fully automated immunological analysis of eight targets, yielding outcomes within an hour. Furthermore, we conducted a comparative analysis of 28 clinical samples with autoimmune diseases. According to 224 clinical data, the sample testing concordance rate between DAVM and the traditional instrument was 82%, with a target compliance rate of 97%. Therefore, our DAVM system has powerful potential for fully automated immunoassays.


Subject(s)
Microfluidic Analytical Techniques , Microfluidics , Point-of-Care Systems , Lab-On-A-Chip Devices , Immunoassay/methods , Immunoblotting
6.
PeerJ ; 11: e15515, 2023.
Article in English | MEDLINE | ID: mdl-37304882

ABSTRACT

Background: To date, several types of laboratory tests for coronavirus disease 2019 (COVID-19) diagnosis have been developed. However, the clinical importance of serum severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid antigen (N-Ag) remains to be fully elucidated. In this study, we sought to investigate the value of serum SARS-CoV-2 N-Ag for COVID-19 diagnosis and to analyze N-Ag characteristics in COVID-19 individuals. Methods: Serum samples collected from 215 COVID-19 patients and 65 non-COVID-19 individuals were used to quantitatively detect N-Ag via chemiluminescent immunoassay according to the manufacturer's instructions. Results: The sensitivity and specificity of the N-Ag assay were 64.75% (95% confidence interval (95% CI) [55.94-72.66%]) and 100% (95% CI [93.05-100.00%]), respectively, according to the cut-off value recommended by the manufacturer. The receiver operating characteristic (ROC) curve showed a sensitivity of 100.00% (95% CI [94.42-100.00%]) and a specificity of 71.31% (95% CI [62.73-78.59%]). The positive rates and levels of serum SARS-CoV-2 N-Ag were not related to sex, comorbidity status or disease severity of COVID-19 (all P < 0.001). Compared with RT‒PCR, there was a lower positive rate of serum N-Ag for acute COVID-19 patients (P < 0.001). The positive rate and levels of serum SARS-CoV-2 N-Ag in acute patients were significantly higher than those in convalescent patients (all P < 0.001). In addition, the positive rate of serum SARS-CoV-2 N-Ag in acute COVID-19 patients was higher than that of serum antibodies (IgM, IgG, IgA and neutralizing antibodies (Nab)) against SARS-CoV-2 (all P < 0.001). However, the positive rate of serum SARS-CoV-2 N-Ag in convalescent COVID-19 patients was significantly lower than that of antibodies (all P < 0.001). Conclusion: Serum N-Ag can be used as a biomarker for early COVID-19 diagnosis based on appropriate cut-off values. In addition, our study also demonstrated the relationship between serum N-Ag and clinical characteristics.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , COVID-19 Testing , SARS-CoV-2 , Nucleocapsid , Antibodies, Neutralizing
7.
Talanta ; 258: 124466, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-36963148

ABSTRACT

This paper proposed a hand-powered centrifugal micropipette-tip strategy, termed HCM, for all-in-one immunoassay combined with a distance-based readout for portable quantitative detection of SARS-CoV-2. The target SARS-CoV-2 virus antigen triggers the binding of multiple monoclonal antibody-coated red latex nanobeads, forming larger complexes. Following incubation and centrifugation, the formed aggregated complexes settle at the bottom of the tip, while free red nanobeads remain suspended in the solution. The HCM enables sensitive (1 ng/mL) and reliable quantification of SARS-CoV-2 within 25 min. With the advantages of free washing, free fabrication, free instrument, and without the optical device, the proposed low-cost and easy-to-use HCM immunoassay shows great potential for quantitative POC diagnostics for SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Immunoassay
8.
J Med Virol ; 95(1): e28356, 2023 01.
Article in English | MEDLINE | ID: mdl-36443279

ABSTRACT

The purpose of this study is to investigate the production of both severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-specific antibodies and autoantibodies in serum following the third booster vaccination of the inactivated COVID-19 vaccine, and to study the effect of B cell subsets with CD27 and CD38 phenotypes in peripheral blood on antibody production. Routine blood indexes, SARS-CoV-2 antibodies, platelet factor 4 and seven antiphospholipid antibodies were detected both before and 2 months after vaccination in the medical staff of the Zhongnan Hospital of Wuhan University. Peripheral blood B cell subtypes were detected before vaccination. Following immunization, the positive rate of anti-N-S1 immunoglobulin (IgG) had increased from 24.8% to 91.3% and the average antibody concentration had increased by 11 times. The positive rate of neutralizing antibody had increased from 24.8% to 91.3%, the average antibody concentration had increased by 12 times, and the primary increased anti-S1 IgG subtype was that of IgG1. Peripheral blood CD27 + CD38+ B cells were positively correlated with antibody levels after vaccination and were a predictor of the antibody response. In addition, although some indicators showed slight absolute changes, the blood parameters and antiphospholipid antibodies of most volunteers were normal both before and after COVID-19 inactivated vaccine inoculation, and there was no statistical difference in abnormal rates either before or after inoculation. Antibodies in vivo were increased after vaccination with the inactivated vaccine, and IgG1 was the main subtype involved in response to the vaccine. Vaccination with the inactivated COVID-19 vaccine did not appear to affect thrombus-related autoantibodies.


Subject(s)
Antibodies, Viral , Antibody Formation , COVID-19 Vaccines , COVID-19 , SARS-CoV-2 , Humans , Antibodies, Antiphospholipid , Antibodies, Neutralizing , Autoantibodies , COVID-19/prevention & control , COVID-19 Vaccines/immunology , Immunoglobulin G/chemistry , SARS-CoV-2/immunology , Vaccination , Vaccines, Inactivated/immunology
9.
Front Immunol ; 13: 855350, 2022.
Article in English | MEDLINE | ID: mdl-35935967

ABSTRACT

We present a case of recurrent autoimmune hypoglycemia induced by non-hypoglycemic agents. We review reported cases of autoimmune hypoglycemia related to non-hypoglycemic agents, and discuss the effects of different detection methods for insulin autoantibodies on the results obtained. We aim to provide information for clinicians and a warning for medication usage. Considering the increasing number of clopidogrel-induced AIH cases and the hypoglycemia-induced increase in the risk of cardiovascular events, we recommend that cardiovascular disease patients being treated with clopidogrel be informed of this rare side effect and that clinicians be vigilant for the possibility of autoimmune hypoglycemia in this patient population.


Subject(s)
Autoimmune Diseases , Hypoglycemia , Autoimmune Diseases/diagnosis , Autoimmune Diseases/drug therapy , Clopidogrel/therapeutic use , Humans , Hypoglycemia/chemically induced , Hypoglycemia/diagnosis , Hypoglycemia/drug therapy , Insulin , Insulin Antibodies/therapeutic use
11.
Health Sci Rep ; 5(3): e572, 2022 May.
Article in English | MEDLINE | ID: mdl-35509410

ABSTRACT

Background: We compared the temporal changes of immunoglobulin M (IgM), IgG, and IgA antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleoprotein (N), spike 1 subunit (S1), and receptor-binding domain (RBD), and neutralizing antibodies (NAbs) against SARS-CoV-2 in patients with coronavirus disease 2019 (COVID-19) to understand the humoral immunity in COVID-19 patients for developing drugs and vaccines for COVID-19. Methods: A total of five confirmed COVID-19 cases in Nissan Tamagawa Hospital in early August 2020 were recruited in this study. Using a fully automated chemiluminescence immunoassay analyzer, we measured the levels of IgG, IgA, and IgM against SARS-CoV-2 N, S1, and RBD and NAbs against SARS-CoV-2 in COVID-19 patients' sera acquired multiple times in individuals from 0 to 76 days after symptom onset. Results: IgG levels against SARS-CoV-2 structural proteins increased over time in all cases but IgM and IgA levels against SARS-CoV-2 showed different increasing trends among individuals in the early stage. In particular, we observed IgA increasing before IgG and IgM in some cases. The NAb levels were more than cut-off value in 4/5 COVID-19 patients some of whose antibodies against RBD did not exceed the cut-off value in the early stage. Furthermore, NAb levels against SARS-CoV-2 increased and kept above cut-off value more than around 70 days after symptom onset in all cases. Conclusion: Our findings indicate COVID-19 patients should be examined for IgG, IgA, and IgM against SARS-CoV-2 structural proteins and NAbs against SARS-CoV-2 to analyze the diversity of patients' immune mechanisms.

12.
Se Pu ; 40(4): 372-383, 2022 Apr.
Article in Chinese | MEDLINE | ID: mdl-35362685

ABSTRACT

Early diagnosis of Epstein-Barr virus (EBV) can reduce the risk of major illnesses. Disadvantages of EBV antibody detection methods that are commonly used clinically include lengthy assay time, need for a lot of reagent, and low efficiency. Compared with traditional detection methods, microfluidics technology offers high throughput, low reagent consumption, less bio-contamination, and a higher degree of automation. Advantages of magnetic immunofluorescence technology include high detection efficiency and a strong signal. The combined advantages of the two methods can compensate for the shortcomings of traditional methods. In the present study, polymethyl methacrylate (PMMA) as the raw material was subjected to laser cutting and vacuum hot pressing to quickly obtain chips. Magnetic beads labeled with antigen and fluorescent microspheres labeled with anti-human antibody were then rapidly lyophilized into microspheres by freeze-drying and embedded into the chips. After incubation and cleaning, the last step was detection. Image J software was used to analyze the mean fluorescence intensity and obtain negative or positive test results. To determine the precision of the chip, high- and low-value samples of each item were retested 10 times. The mean values were calculated to obtain the relative standard deviation (RSD) for several common pathogens. Furthermore, the coincidence rate of clinical samples was tested using a chemiluminescence immunoassay (CLIA) to determine the potential clinical application value. The RSD of the precision test for each item was <10%, indicating good precision. The precision of the accelerated stability test was not verified. Specificity test results revealed no cross-reaction with some common pathogen antibodies, indicating good specificity. It remains to be verified whether the antibodies detected by this method cross-react with other herpes simplex viruses, such as types 1 and 2, Kaposi's sarcoma-associated virus, and human herpes virus type 6 and 7. Of the 121 clinical samples tested, statistical analysis of the data indicated good agreement with the chemiluminescence immunoassay in clinical trials. EB viral capsid antigen (EB VCA) IgG positive coincidence rate was 95.77% (68/71), the negative coincidence rate was 86% (43/50) (Kappa=0.828, P<0.05), the limit of detection (LOD) was 1.92 U/mL, and the linear range was 1.92 to 200 U/mL. The EB VCA IgA positive coincidence rate was 92% (46/50), negative coincidence rate was 92.96% (66/71) (Kappa=0.847, P<0.05), LOD was 2.79 U/mL, and the linear range was 2.79 to 200 U/mL. The positive coincidence rate of EB nuclear antigen 1 (EB NA1) IgG was 92.96% (66/71), the negative coincidence rate was 92% (46/50) (Kappa=0.847, P<0.05), the LOD was 3.13 U/mL, and the linear range was 3.13 to 200 U/mL. The positive coincidence rate of EB NA1 IgA was 90% (45/50), the negative coincidence rate was 91.55% (65/71) (Kappa=0.813, P<0.05), the LOD was 1.53 U/mL, and the linear range was 1.53 to 200 U/mL. Compared with the traditional enzyme-linked immunosorbent assay, the novel method featured a shorter detection time, reduced use of reagent, high degree of automation, and less bio-contamination. Compared with CLIA, advantages of the novel method include multi-item combined detection, long luminescence time, and simple use as a basic health service. Compared with silicon and ceramic microfluidic chips, advantages of the selected PMMA material include low processing cost, short processing time, simple processing technology, and easy industrialization. A refinement that can still be made include the use of molding instead of laser cutting technology, which can further shorten the chip processing time. In summary, a microfluidic detection platform was initially built to provide a rapid, sensitive, simple, highly automated, and easy to be used by basic health service for the quantitative combined detection of EBV VCA and EB NA1 IgG and IgA.


Subject(s)
Epstein-Barr Virus Infections , Herpesvirus 4, Human , Epstein-Barr Virus Infections/diagnosis , Fluorescent Antibody Technique , Humans , Magnetic Phenomena , Microfluidics , Technology
13.
Front Immunol ; 13: 811952, 2022.
Article in English | MEDLINE | ID: mdl-35126396

ABSTRACT

Numerous studies have suggested that the titers of antibodies against SARS-CoV-2 are associated with the COVID-19 severity, however, the types of antibodies associated with the disease maximum severity and the timing at which the associations are best observed, especially within one week after symptom onset, remain controversial. We attempted to elucidate the antibody responses against SARS-CoV-2 that are associated with the maximum severity of COVID-19 in the early phase of the disease, and to investigate whether antibody testing might contribute to prediction of the disease maximum severity in COVID-19 patients. We classified the patients into four groups according to the disease maximum severity (severity group 1 (did not require oxygen supplementation), severity group 2a (required oxygen supplementation at low flow rates), severity group 2b (required oxygen supplementation at relatively high flow rates), and severity group 3 (required mechanical ventilatory support)), and serially measured the titers of IgM, IgG, and IgA against the nucleocapsid protein, spike protein, and receptor-binding domain of SARS-CoV-2 until day 12 after symptom onset. The titers of all the measured antibody responses were higher in severity group 2b and 3, especially severity group 2b, as early as at one week after symptom onset. Addition of data obtained from antibody testing improved the ability of analysis models constructed using a machine learning technique to distinguish severity group 2b and 3 from severity group 1 and 2a. These models constructed with non-vaccinated COVID-19 patients could not be applied to the cases of breakthrough infections. These results suggest that antibody testing might help physicians identify non-vaccinated COVID-19 patients who are likely to require admission to an intensive care unit.


Subject(s)
Antibodies, Viral/blood , COVID-19 Vaccines/blood , COVID-19/blood , SARS-CoV-2/immunology , Severity of Illness Index , Vaccination Hesitancy , Antibody Formation/immunology , COVID-19/immunology , COVID-19/pathology , COVID-19 Vaccines/immunology , Coronavirus Nucleocapsid Proteins/immunology , Humans , Immunoglobulin A/blood , Immunoglobulin G/blood , Immunoglobulin M/blood , Machine Learning , Protein Domains/immunology , Spike Glycoprotein, Coronavirus/immunology , Time Factors , Vaccination
14.
J Epidemiol ; 32(2): 105-111, 2022 02 05.
Article in English | MEDLINE | ID: mdl-34776499

ABSTRACT

BACKGROUND: Tokyo, the capital of Japan, is a densely populated city of >13 million people, so the population is at high risk of epidemic severe acute respiratory coronavirus 2 (SARS-CoV-2) infection. A serologic survey of anti-SARS-CoV-2 IgG would provide valuable data for assessing the city's SARS-CoV-2 infection status. Therefore, this cross-sectional study estimated the anti-SARS-CoV-2 IgG seroprevalence in Tokyo. METHODS: Leftover serum of 23,234 hospital visitors was tested for antibodies against SARS-CoV-2 using an iFlash 3000 chemiluminescence immunoassay analyzer (Shenzhen YHLO Biotech, Shenzhen, China) with an iFlash-SARS-CoV-2 IgG kit (YHLO) and iFlash-SARS-CoV-2 IgG-S1 kit (YHLO). Serum samples with a positive result (≥10 AU/mL) in either of these assays were considered seropositive for anti-SARS-CoV-2 IgG. Participants were randomly selected from patients visiting 14 Tokyo hospitals between September 1, 2020 and March 31, 2021. No participants were diagnosed with coronavirus disease 2019 (COVID-19), and none exhibited COVID-19-related symptoms at the time of blood collection. RESULTS: The overall anti-SARS-CoV-2 IgG seroprevalence among all participants was 1.83% (95% confidence interval [CI], 1.66-2.01%). The seroprevalence in March 2021, the most recent month of this study, was 2.70% (95% CI, 2.16-3.34%). After adjusting for population age, sex, and region, the estimated seroprevalence in Tokyo was 3.40%, indicating that 470,778 individuals had a history of SARS-CoV-2 infection. CONCLUSIONS: The estimated number of individuals in Tokyo with a history of SARS-CoV-2 infection was 3.9-fold higher than the number of confirmed cases. Our study enhances understanding of the SARS-CoV-2 epidemic in Tokyo.


Subject(s)
COVID-19 , Antibodies, Viral , Cross-Sectional Studies , Hospitals , Humans , Immunoglobulin G , SARS-CoV-2 , Seroepidemiologic Studies , Tokyo/epidemiology
15.
Int Immunopharmacol ; 103: 108491, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34954559

ABSTRACT

To better understand the immune responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in individuals with COVID-19, it is important to investigate the kinetics of the antibody responses and their associations with the clinical course in different populations, since there seem to be considerable differences between Western and Asian populations in the clinical features and spread of COVID-19. In this study, we serially measured the serum titers of IgM, IgG and IgA antibodies generated against the nucleocapsid protein (NCP), S1 subunit of the spike protein (S1), and receptor-binding domain in the S1 subunit (RBD) of SARS-CoV-2 in Japanese individuals with COVID-19. Among the IgM, IgG, and IgA antibodies, IgA antibodies against all of the aforementioned viral proteins were the first to appear after the infection, and IgG and/or IgA seroconversion often preceded IgM seroconversion. In regard to the timeline of the antibody responses to the different viral proteins (NCP, S1 and RBD), IgA against NCP appeared than IgA against S1 or RBD, while IgM and IgG against S1 appeared earlier than IgM/IgG against NCP or RBD. The IgG responses to all three viral proteins and responses of all three antibody classes to S1 and RBD were sustained for longer durations than the IgA/IgM responses to all three viral proteins and responses of all three antibody classes to NCP, respectively. The seroconversion of IgA against NCP occurred later and less frequently in patients with mild COVID-19. These results suggest possible differences in the antibody responses to SARS-CoV-2 antigens between the Japanese and Western populations.


Subject(s)
COVID-19/epidemiology , COVID-19/immunology , Immunoglobulin A/blood , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2 , Antibody Formation , Asian People , Humans , Immunoglobulin A/immunology , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Japan/epidemiology , Japan/ethnology , Seroconversion , Viral Proteins/immunology
16.
Front Microbiol ; 12: 791489, 2021.
Article in English | MEDLINE | ID: mdl-34956158

ABSTRACT

Background: Several types of laboratory tests for COVID-19 have been established to date; however, the clinical significance of the serum SARS-CoV-2 nucleocapsid (N) antigen levels remains to be fully elucidated. In the present study, we attempted to elucidate the usefulness and clinical significance of the serum N antigen levels. Methods: We measured the serum N antigen levels in 391 serum samples collected from symptomatic patients with a confirmed diagnosis of COVID-19 and 96 serum samples collected from patients with non-COVID-19, using a fully automated chemiluminescence immunoassay analyzer. Results: Receiver operating characteristic analysis identified the optimal cutoff value of the serum N antigen level (cutoff index, based on Youden's index) as 0.255, which yielded a sensitivity and specificity for the diagnosis of COVID-19 of 91.0 and 81.3%, respectively. The serum N antigen levels were significantly higher in the patient groups with moderate and severe COVID-19 than with mild disease. Moreover, a significant negative correlation was observed between the serum N antigen levels and the SARS-CoV-2 IgG antibody titers, especially in patients with severe COVID-19. Conclusion: Serum N antigen testing might be useful both for the diagnosis of COVID-19 and for obtaining a better understanding of the clinical features of the disease.

17.
Front Bioeng Biotechnol ; 9: 733810, 2021.
Article in English | MEDLINE | ID: mdl-34490230

ABSTRACT

Continuous glucose monitors (CGMs) for the non-invasive monitoring of diabetes are constantly being developed and improved. Although there are multiple biosensing platforms for monitoring glucose available on the market, there is still a strong need to enhance their precision, repeatability, wearability, and accessibility to end-users. Biosensing technologies are being increasingly explored that use different bodily fluids such as sweat and tear fluid, etc., that can be calibrated to and therefore used to measure blood glucose concentrations accurately. To improve the wearability of these devices, exploring different fluids as testing mediums is essential and opens the door to various implants and wearables that in turn have the potential to be less inhibiting to the wearer. Recent developments have surfaced in the form of contact lenses or mouthguards for instance. Challenges still present themselves in the form of sensitivity, especially at very high or low glucose concentrations, which is critical for a diabetic person to monitor. This review summarises advances in wearable glucose biosensors over the past 5 years, comparing the different types as well as the fluid they use to detect glucose, including the CGMs currently available on the market. Perspectives on the development of wearables for glucose biosensing are discussed.

18.
Signal Transduct Target Ther ; 6(1): 256, 2021 07 07.
Article in English | MEDLINE | ID: mdl-34234102

ABSTRACT

We collected blood from coronavirus disease 2019 (COVID-19) convalescent individuals and investigated SARS-CoV-2-specific humoral and cellular immunity in these discharged patients. Follow-up analysis in a cohort of 171 patients at 4-11 months after the onset revealed high levels of IgG antibodies. A total of 78.1% (164/210) of the specimens tested positive for neutralizing antibody (NAb). SARS-CoV-2 antigen peptide pools-stimulated-IL-2 and -IFN-γ response can distinguish COVID-19 convalescent individuals from healthy donors. Interestingly, NAb survival was significantly affected by the antigen peptide pools-stimulated-IL-2 response, -IL-8 response, and -IFN-γ response. The antigen peptide pools-activated CD8+ T cell counts were correlated with NAb. The antigen peptide pools-activated natural killer (NK) cell counts in convalescent individuals were correlated with NAb and disease severity. Our data suggested that the development of NAb is associated with the activation of T cells and NK cells. Our work provides a basis for further analysis of the protective immunity to SARS-CoV-2 and for understanding the pathogenesis of COVID-19. It also has implications for the development of an effective vaccine for SARS-CoV-2 infection.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/immunology , Adult , Aged , Aged, 80 and over , Convalescence , Cytokines/immunology , Female , Humans , Immunity, Cellular , Immunity, Humoral , Immunoglobulin G/immunology , Lymphocyte Subsets/immunology , Male , Middle Aged , Young Adult
20.
PLoS One ; 16(3): e0247711, 2021.
Article in English | MEDLINE | ID: mdl-33661990

ABSTRACT

PCR methods are presently the standard for the diagnosis of Coronavirus disease 2019 (COVID-19), but additional methodologies are needed to complement PCR methods, which have some limitations. Here, we validated and investigated the usefulness of measuring serum antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using the iFlash3000 CLIA analyzer. We measured IgM and IgG titers against SARS-CoV-2 in sera collected from 26 PCR-positive COVID-19 patients, 53 COVID-19-suspected but PCR-negative patients, and 20 and 100 randomly selected non-COVID-19 patients who visited our hospital in 2020 and 2017, respectively. The repeatability and within-laboratory precision were obviously good in validations, following to the CLSI document EP15-A3. Linearity was also considered good between 0.6 AU/mL and 112.7 AU/mL for SARS-CoV-2 IgM and between 3.2 AU/mL and 55.3 AU/mL for SARS-CoV-2 IgG, while the linearity curves plateaued above the upper measurement range. We also confirmed that the seroconversion and no-antibody titers were over the cutoff values in all 100 serum samples collected in 2017. These results indicate that this measurement system successfully detects SARS-CoV-2 IgM/IgG. We observed four false-positive cases in the IgM assay and no false-positive cases in the IgG assay when 111 serum samples known to contain autoantibodies were evaluated. The concordance rates of the antibody test with the PCR test were 98.1% for SARS-CoV-2 IgM and 100% for IgG among PCR-negative cases and 30.8% for SARS-CoV-2 IgM and 73.1% for SARS-CoV-2 IgG among PCR-positive cases. In conclusion, the performance of this new automated method for detecting antibody against both N and S proteins of SARS-CoV-2 is sufficient for use in laboratory testing.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2/isolation & purification , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/epidemiology , COVID-19/immunology , Coronavirus Nucleocapsid Proteins/immunology , Coronavirus Nucleocapsid Proteins/isolation & purification , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Japan/epidemiology , Luminescent Measurements/methods , Phosphoproteins/immunology , Phosphoproteins/isolation & purification , SARS-CoV-2/immunology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL
...