Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Europace ; 17(11): 1712-9, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25825459

ABSTRACT

AIMS: Fragmented QRS (f-QRS) complexes are associated with adverse cardiovascular events in patients with coronary heart disease; however, the effects on patients with dilated cardiomyopathy (DCM) remain elusive. This study is to investigate the changes of left ventricular (LV) synchrony and systolic function in DCM patients with f-QRS complexes. METHODS AND RESULTS: Twenty DCM patients with f-QRS complexes and 29 DCM patients without f-QRS (n-QRS) complexes were enrolled. The LV segmental longitudinal, radial and circumferential time to peak strain and general longitudinal systolic strain, radial strain, circumferential strain were measured, respectively, by speckle tracking imaging. The LV segmental standard deviations and maximal differences were also calculated. The LV dyssynchrony was defined as the time in peak anteroseptal wall to posterior wall strain >130 ms or longitudinal strain delay index >25%. The mean QRS durations in f-QRS and n-QRS groups were not different (P = ns). The incidence of LV dyssynchrony was 15/20 (75%) vs. 5/29 (17%) in two groups (P < 0.01). Two patients died of sudden death in f-QRS group during 2 years follow-up; however, no death in n-QRS group (P < 0.05). Patients in f-QRS group showed worsening LV dyssynchrony in f-QRS group after 2 years follow-up (P < 0.05). Overall, LV function was comparable at baseline (P = ns), but had significantly worsened only in the f-QRS group (P < 0.05). CONCLUSION: The f-QRS complex is significantly associated with LV dyssynchrony in DCM patients and can be used as a reliable index to evaluate ventricular synchrony and predict the prognosis in DCM patients with narrow QRS complexes.


Subject(s)
Arrhythmias, Cardiac/etiology , Cardiomyopathy, Dilated/complications , Heart Conduction System/physiopathology , Ventricular Dysfunction, Left/etiology , Ventricular Function, Left , Action Potentials , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/mortality , Arrhythmias, Cardiac/physiopathology , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/mortality , Cardiomyopathy, Dilated/physiopathology , Case-Control Studies , Death, Sudden, Cardiac/etiology , Echocardiography, Doppler, Color , Electrocardiography , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Risk Factors , Systole , Time Factors , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathology
2.
Zhonghua Xin Xue Guan Bing Za Zhi ; 41(11): 940-4, 2013 Nov.
Article in Chinese | MEDLINE | ID: mdl-24370222

ABSTRACT

OBJECTIVE: To investigate the effects of cardiac resynchronization therapy (CRT) on left ventricular (LV) diastolic function measured by speckle tracking imaging (STI) in patients with dilated cardiomyopathy (DCM). METHODS: CRT was performed in 21 DCM patients [15 male, mean age: 61.2 ± 11.2 (49-82) years].LV synchronization, LV systolic function and LV diastolic function were evaluated with conventional echocardiography, tissue Doppler imaging and STI before and 6 months after CRT.NYHA heart function was also assessed. Clinic Response to CRT was defined as improvement of more than 1 NYHA class.Response to CRT in echocardiography was defined as ≥ 15% reduction in LV end systolic volume at 6 months post CRT. RESULTS: There were 16 responders and 5 non-responders at 6 months post CRT.In terms of diastolic function, conventional echocardiography derived deceleration time was both prolonged in non-responders and responders. At 6 months post CRT, STI derived LV isovolumetric diastolic strain rate [(0.19 ± 0.11) /s vs.(0.14 ± 0.09)/s, P < 0.001] was significantly increased while early diastolic mitral valve blood flow velocity/left ventricular isovolumetric diastolic strain rate (680 ± 600 vs.787 ± 690, P < 0.04) was significantly reduced in responder group while remained unchanged in non-responder group.Furthermore, left ventricular isovolumetric diastolic strain rate negatively correlated with plasma brain natriuretic peptide level (r = -0.68, P < 0.05). CONCLUSION: In CRT responders of DCM patients, LV diastolic function is significantly improved and this change could be detected more effectively by STI derived LV diastolic function parameters.


Subject(s)
Cardiac Resynchronization Therapy , Cardiomyopathy, Dilated/therapy , Diagnostic Imaging , Ventricular Function, Left , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
3.
Exp Ther Med ; 6(5): 1213-1219, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24223646

ABSTRACT

The aim of this study was to evaluate the left ventricular mechanical dyssynchrony (LVMD) and left ventricular dysfunction of patients in AAI, DDD and VVI pacing modes using real-time three-dimensional echocardiography (RT3DE) and tissue Doppler imaging (TDI). The results from the RT3DE and TDI were subsequently compared. Twenty patients with sick sinus syndrome (SSS) who had undergone the implantation of a dual-chamber pacemaker were enrolled in this study and the pacemakers were programmed to AAI, DDD and VVI modes, sequentially. The RT3DE and TDI parameters were obtained following pacing for 24 h in each mode. With RT3DE, we measured the systolic dyssynchrony indices, including Tmsv16-SD%, Tmsv12-SD%, Tmsv6-SD%, Tmsv16-Dif%, Tmsv12-Dif% and Tmsv6-Dif%, left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF), respectively. With TDI, we measured the standard deviation and the maximal difference in time from the QRS onset to the peak systolic velocity for 12 left ventricular myocardial segments, i.e. Ts-SD and Ts-Dif, respectively. The results showed that the Tmsv16-SD% and Ts-SD in the AAI mode were significantly lower than those in the DDD and VVI modes (P<0.05); however, there were no significant differences between the DDD and VVI modes (P>0.05). The LVEF in the AAI, DDD and VVI modes was 63.1±8.9, 58.6±11.2 and 57.9±7.6%, respectively (P>0.05). There were negative correlations between the LVEF and Tmsv16-SD% (r, -0.651; P<0.001) and Ts-SD (r, -0.649; P<0.0001). A moderate correlation (r, 0.698; P<0.0001) was observed between Tmsv16-SD% and Ts-SD. The concordance rate between Tmsv16-SD% and Ts-SD for detecting LVMD was 76%. This study showed that DDD and VVI pacing modes induced significant LVMD and a reduction in LVEF, unlike the AAI pacing mode. RT3DE and TDI were capable of objectively evaluating LVMD; however, each method had certain faults. At present, there is a lack of a uniform standard for assessing LVMD; therefore, the use of a variety of techniques and indices is necessary in order to comprehensively evaluate LVMD in patients with different cardiac pacing modes.

4.
Zhonghua Xin Xue Guan Bing Za Zhi ; 40(2): 147-52, 2012 Feb.
Article in Chinese | MEDLINE | ID: mdl-22490716

ABSTRACT

OBJECTIVE: To evaluate left ventricular (LV) function and twist in patients with diabetic cardiovascular autonomic neuropathy (CAN) by two-dimensional speckle tracking imaging (STI). METHODS: STI was performed in 56 subjects with type 2 diabetes mellitus (DM) (35 with DM only: group A, 21 with CAN: group B) and 34 normal subjects (Control) from LV short-axis view. LV peak systolic, peak early (E') and peak late (A') diastolic circumferential strain in 18 myocardial segments were measured at the levels of mitral annulus, papillary muscle and apex and the rotation at mitral annulus and apex levels were also measured. LV peak systolic and the ratio of E' and A' of global and three levels, twist, untwisting rate and untwisting half-time were calculated. RESULTS: In group A, compared with control group, LV peak systolic radial circumferential strain has no significant difference (P > 0.05), E'/A' was reduced (P < 0.05), twist at aortic valve closure and twist at mitral valve opening were significantly increased (P < 0.05), untwisting rate reduced, and untwisting half time delayed. In group B, compared with control group and group A, circumferential strain parameters [(-12.64 ± 6.49)% vs. (-19.11 ± 9.98)% and (-21.14 ± 10.13)%, P < 0.05] and E'/A' [(0.90 ± 0.35) vs. (1.24 ± 0.47) and (1.98 ± 0.63), P < 0.05] were significantly decreased, twist at aortic valve closure [(19.08 ± 5.62)° vs. (16.57 ± 2.84)° and (14.36 ± 4.06)°, P < 0.05] and twist at mitral valve opening [(13.99 ± 2.31)° vs. (11.36 ± 2.63)° and (9.04 ± 5.63)°, P < 0.05] were significantly increased, untwisting rate [(0.40 ± 0.28)%/ms vs. (0.46 ± 0.14)%/ms and (0.53 ± 0.21)%/ms, P < 0.05] reduced, and untwisting half time [(489.61 ± 97.14) ms vs. (445.21 ± 54.53) ms and (410.60 ± 50.23) ms, P < 0.05] delayed. CONCLUSION: Speckle tracking imaging could be used to evaluate early changes on LV twist deformation and LV systolic function in patients with type 2 diabetes mellitus.


Subject(s)
Diabetes Mellitus, Type 2/physiopathology , Diabetic Neuropathies/physiopathology , Diagnostic Imaging/methods , Ventricular Dysfunction, Left/physiopathology , Diabetes Mellitus, Type 2/diagnosis , Diabetic Neuropathies/diagnosis , Diastole , Female , Humans , Male , Middle Aged , Rotation , Stroke Volume , Systole , Ventricular Function, Left
5.
Zhonghua Xin Xue Guan Bing Za Zhi ; 38(3): 215-9, 2010 Mar.
Article in Chinese | MEDLINE | ID: mdl-20450562

ABSTRACT

OBJECTIVE: To determine the feasibility on the left ventricular systolic synchronism and cardiac function evaluation in patients with permanent cardiac pacing by real-time three-dimensional echocardiography. METHODS: Fifteen patients with sick sinus syndrome post dual-chamber pacemaker implantation were enrolled in this study. Pacemakers were programmed to AAI, DDD, and VVI respectively. After pacing for 5 minutes in each mode, participants were examined with real-time three-dimensional echocardiography. Images in different pacing modes were obtained and analyzed by the off-line Qlab 4.2 software. Parameters including global and 17-segmental volume-time curves (VTCs), dispersion of time to minimal regional volume for 16, 12, and 6 left ventricular segments (Tmsv16-s, Tmsv12-s, Tmsv6-s), and maximal difference of time to minimal regional volume for l6, 12 and 6 left ventricular segments (Tmsv16-dif, Tmsv12-dif, Tmsv6-dif), end diastolic volume (EDV), end systolic volume (ESV), left ventricular ejection fraction (LVEF) were measured respectively. Parameters of peak filling rate (PFR), regional end diastolic volume (rEDV), regional end systolic volume (rESV), and regional ejection fraction (rEF) were also calculated. RESULTS: Left ventricular systolic synchronism as reflected by VTCs, Tmsv16-s, Tmsv12-s, Tmsv6-s, Tmsv16-dif, Tmsv12-dif and Tmsv6-dif as well as parameters reflecting ventricular function, i.e., LVEF, PFR were significantly better in AAI mode than in DDD and VVI models (all P < 0.05). All above indexes were similar between DDD and VVI models (all P > 0.05). rEFs of left inferior wall in base, septum in base and apex were significantly lower in DDD and VVI models compared that in AAI mode (P < 0.05). CONCLUSION: Real-time three-dimensional echocardiography can objectively and accurately evaluate left ventricular systolic synchronism and cardiac function in patients with permanent cardiac pacing and AAI mode is superior to DDD and VVI models.


Subject(s)
Cardiac Pacing, Artificial , Echocardiography, Three-Dimensional/methods , Sick Sinus Syndrome/diagnostic imaging , Sick Sinus Syndrome/physiopathology , Adult , Aged , Female , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Ventricular Function, Left
7.
Zhonghua Xin Xue Guan Bing Za Zhi ; 36(9): 820-4, 2008 Sep.
Article in Chinese | MEDLINE | ID: mdl-19102866

ABSTRACT

OBJECTIVE: To study change and the value of diagnosis of harmonic imaging ultrasonic integrated backscatter (IBS) on the very early diagnosis of acute myocardial infarction (AMI). METHOD: 72 patients were divided 2 groups, A group 30 cases with AMI at the very early stage of acute myocardial infarction (in 2 hours), B group 42 cases with typical acute myocardial infarction (in 2 - 12 hours) were examined by IBS and the cyclic variation of integrated backscatter (CVIB) with HP-5500 ultrasonic system in the segment of myocardial infarction and no myocardial infarction. RESULTS: In A group the IBS of the segment of AMI are very higher than that of the segment of no AMI [(18.8 +/- 3.4) dB vs (8.3 +/- 1.2) dB, P < 0.01], the CVIB are lower [(6.3 +/- 0.7) dB vs (7.6 +/- 1.1) dB, P < 0.01]. But in the meanwhile there are no obvious changes in ECG. In B group the IBS of the segment of AMI is obvious higher than the normal person and no infarction segment in the same heart [(22.2 +/- 4.1) dB vs (8.3 +/- 1.2) dB, (21.1 +/- 3.2) dB vs (8.7 +/- 0.9) dB, P < 0.05], but CVIB is obvious lower than the normal person and no infarction segment in the same heart [(5.6 +/- 0.8) dB vs (7.6 +/- 1.1) dB, P < 0.05; (5.8 +/- 0.7) dB vs (9.3 +/- 0.9) dB, P < 0.01], the changes of the ultrasonic is coincidence with ECG. The change of IBS are very obvious just as in ECG. CONCLUSION: The result demonstrate that ultrasonic tissue characterization with harmonic imaging integrated backscatter can be used for diagnosis the very early stage of AMI, and can judge the segment range of AMI and function of the whole heart.


Subject(s)
Echocardiography/methods , Myocardial Infarction/diagnostic imaging , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnosis , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...