Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 1317: 342866, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39030026

ABSTRACT

BACKGROUND: Cardiac troponin I (CTnI) is demonstrated as one of the most promising disease biomarkers for early diagnosing acute myocardial infarction (AMI). To date, electrochemical immunosensors have been extensively studied in the field of cTnI determination. But highly accurate and sensitive cTnI detection by this method is still a challenge due to non-specific adsorption on electrode interfaces in complex human serum. As a result, it is necessary to develop an antifouling electrochemical immunosensor with high sensitivity for the detection of cTnI. RESULTS: In this work, an antifouling electrochemical immunosensor was constructed based on vertically-aligned peptide layer consisting of Au nanoparticles (AuNPs) and amphiphilic CEAK16 peptide (CEAK16@AuNPs) for sensitive and accurate detection of cTnI in human serum. The vertically-aligned CEAK16@AuNPs interface provided a stable hydration layer originated from attraction of water molecules by amino acids on the hydrophilic side of the CEAK16, which effectively reduced non-specific adsorption and enhanced electron transfer rate. The cTnI immunosensor possessed great analytical performance with a wide range from 1 fg mL-1 to 1 µg mL-1 and a low detection limit of 0.28 fg mL-1 (S/N = 3). Additionally, the proposed CEAK16@AuNPs sensing interface showed excellent long-term antifouling performance and electrochemical activity that preserved 80 % of the initial signal after 20-days exposure in human serum samples. Consequently, the cTnI immunosensor displayed excellent detection accuracy compared to clinical methods and owned good selectivity, stability and reproducibility. SIGNIFICANCE: The development of this strategy provides a versatile tool for accurate quantitative cTnI analysis in real human serum, thus helping to achieve early AMI diagnosis effectively and holding the promising potentials for other immunosensor in disease diagnosis.


Subject(s)
Electrochemical Techniques , Gold , Metal Nanoparticles , Troponin I , Humans , Troponin I/blood , Gold/chemistry , Metal Nanoparticles/chemistry , Limit of Detection , Biosensing Techniques , Peptides/chemistry , Immunoassay/methods , Antibodies, Immobilized/immunology , Antibodies, Immobilized/chemistry , Electrodes
SELECTION OF CITATIONS
SEARCH DETAIL
...