Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
IEEE Trans Biomed Eng ; PP2024 May 16.
Article in English | MEDLINE | ID: mdl-38753478

ABSTRACT

OBJECTIVE: Respiratory regulation is critical for patients with respiratory dysfunction. Clinically used ventilators can lead to long-term dependence and injury. Extracorporeal assistance approaches such as iron-lung devices provide a noninvasive alternative, however, artificial actuator counterparts have not achieved marvelous biomimetic ventilation as human respiratory muscles. Here, we propose a bionic soft exoskeleton robot that can achieve extracorporeal closed-loop respiratory regulation by emulating natural human breath. METHODS: For inspiration, a soft vacuum chamber is actuated to produce negative thoracic pressure and thus expand lung volume by pulling the rib cage up and outward through use of external negative pressure. For expiration, a soft origami array under positive pressure pushes the abdominal muscles inward and the diaphragm upward. To achieve in vitro measurement of respiratory profile, we describe a wireless respiratory monitoring device to measure respiratory profiles with high accuracy, validated by quantitative comparisons with spirometer as gold-standard reference. By constructing a human-robot coupled respiratory mechanical model, a model-based proportional controller is designed for continuous tracking of the target respiratory profile. RESULTS: In experiments with ten healthy participants and ten patients with respiratory difficulty, the robot can adjust its assistive forces in real time and drive human-robot coupling respiratory system to track the target profile. CONCLUSION: The biomimetic robot can achieve extracorporeal closed-loop respiratory regulation for a diverse population. SIGNIFICANCE: The soft robot has important potential to assist respiration for people with respiratory difficulty, whether in a hospital or a home setting.

2.
Zhongguo Gu Shang ; 25(2): 165-8, 2012 Feb.
Article in Chinese | MEDLINE | ID: mdl-22577726

ABSTRACT

OBJECTIVE: To design a new type two-head automatic pressure external fixator and explore its clinical effects in treating intertrochanteric fracture of the femur. METHODS: Base on unilateral angulated external fixator and Ilizarov techiques, a new type two-head automatic pressure external fixator were designed and made. From October 2006 to December 2010, 120 patients with intertrochanteric fracture of the femur were treated with the new type two-head automatic pressure external fixator. There were 67 males and 53 females with an average age of 76.7 years (ranged, 60 to 93 years). According to Evans classification, type I was in 65 cases, type II in 41, type III a in 10, type III b in 2 and type IV in 2. Operative time was from 0 to 11 days after injury with an average 5 days. Postoperative functional recovery was evaluated according to criteria of Sanders. RESULTS: Among 120 patients, 116 cases were followed up with an average of 12 months (ranged, 2 to 24 months). All fractures obtained healing with average healing time of 12 weeks (ranged, 10 to 13 weeks). Five cases occurred with superficial infection of pin site and no deep infection,non-union, coxa adducta were found. Joint function of hip recovered well. According to Sanders scoring, pain, walking, function, muscle strength, daily activities and X-ray estimate were respectively (9.07 +/- 0.41), (9.23 +/- 1.00), (9.42 +/- 1.10), (9.31 +/- 1.06), (9.22 +/- 1.03), (10.00 +/- 0.00) with total amount of (56.27 +/- 4.16). A hundred and six cases got an excellent results, 6 good, 4 poor. CONCLUSION: The new type two-head automatic pressure external fixator is easy and convenient to apply in operation. It has duplicate functions of load and minimal invasive. It is an ideal method for treatment of the intertrochanteric fracture of the femur in high-risk and senile patients.


Subject(s)
External Fixators , Fracture Fixation, Intramedullary/instrumentation , Hip Fractures/surgery , Aged , Aged, 80 and over , Female , Fracture Fixation, Intramedullary/methods , Humans , Male , Middle Aged , Prosthesis Design
3.
Zhongguo Gu Shang ; 21(10): 771-3, 2008 Oct.
Article in Chinese | MEDLINE | ID: mdl-19105376

ABSTRACT

OBJECTIVE: To investigate the mechanical characteristics of new type two-head automatic pressure external fixator in the view of biomechanics. METHODS: Fifteen fresh and humid specimens were selected and divided into experimental group (5 cases) and control group (10 cases). The control group were respectively applied with DHS (5 cases) and traditional external fixator (5 cases). In order to compare the different apparatus, the strength, stiffness and twist mechanical function of femoral intertrochanteric fracture with different device were measured respectively when the specimens were under the pressure of 0-1800 N and loading speed 1.4 mn/min. RESULTS: The strength, stiffness, twist mechanical function and maximum endurance of femora in the experimental group were obviously superior than that of DHS and traditional external fixator (P < 0.05). CONCLUSION: Two head automatic new type pressure external fixator can embed more tightly without sliding, also can prevent the occurrence of coxa vara effectively.


Subject(s)
External Fixators , Femoral Fractures/surgery , Fracture Fixation/instrumentation , Fracture Fixation/methods , Humans , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...