Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Methods ; 15(42): 5607-5619, 2023 Nov 02.
Article in English | MEDLINE | ID: mdl-37850478

ABSTRACT

In this study, new red light-emitting carbon dots (R-CDs) that can selectively recognize Cr(VI) were prepared using a strategy that utilizes 2,4-diaminophenol to enhance the fluorescence of O-phenylenediamine based carbon dots. The results showed that 2,4-diaminophenol increased the quantum yield (QY) of the carbon quantum dots (CDs), and that the QY of the CDs increased from their original value of 8.7% to 20.1% (R-CDs). The R-CDs show sensitivity to acidic conditions and maintain good linearity between pH = 1.00-4.00, making them useful as pH probes. Furthermore, the prepared R-CDs possess good solubility in water and are responsive to changes in Cr(VI) concentrations in aqueous environments. The quenching of the R-CDs fluorescence was linearly correlated with the Cr(VI) concentration within a range of 0-20 µM, with a lower detection limit of 66 nM. The detection mechanism is attributed to the formation of hydrogen bonds between Cr(VI) and the R-CDs, resulting in the fluorescence quenching of the R-CDs. The R-CDs can be considered effective multifunctional fluorescent probes for both pH and Cr(VI) in aqueous environments. This study will provide new R-CD design strategies for probes that selectively identify specific target substances.

2.
J Environ Sci (China) ; 35: 38-42, 2015 Sep 01.
Article in English | MEDLINE | ID: mdl-26354690

ABSTRACT

An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction. The extraction procedure (including loading, washing, and eluting) used a flow rate of 1.0mL/min, and dicyandiamide was eluted with 20mL of a methanol/acetonitrile mixture (V/V=2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography-ultraviolet spectroscopy (HPLC-UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge (with activated carbon). Separation was achieved on a ZIC(®)-Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50mm×2.1mm, 3.5µm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions (R(2)>0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations (RSDs, n=3) were below 6.1% with a detection limit of 5.0ng/mL for stream water samples.


Subject(s)
Chromatography, High Pressure Liquid , Environmental Monitoring/methods , Guanidines/analysis , Rivers/chemistry , Solid Phase Extraction , Spectrophotometry, Ultraviolet , Water Pollutants, Chemical/analysis , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL
...