J Cardiovasc Electrophysiol ; 31(7): 1678-1686, 2020 07.
Article in English | MEDLINE | ID: mdl-32314841

ABSTRACT

INTRODUCTION: Catheter stability during atrial fibrillation ablation is associated with higher ablation success rates. Rapid cardiac pacing and high-frequency jet ventilation (HFJV) independently improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied. The objective of this study was to determine the effect of simultaneous heart rate and respiratory rate modulation on catheter stability. METHODS: Forty patients undergoing paroxysmal atrial fibrillation ablation received ablation lesions at 15 prespecified locations (12 left atria, 3 right atria). Patients were randomly assigned to undergo rapid atrial pacing for either the first or the second half of each lesion. Within each group, half of the patients received HFJV and the other half standard ventilation. Contact force and ablation data for all lesions were compared among the study groups. Standard deviation of contact force was the primary endpoint defined to examine contact force variability. RESULTS: Lesions with no pacing and standard ventilation had the greatest contact force standard deviation (5.86 ± 3.08 g), compared to lesions with pacing and standard ventilation (5.45 ± 3.28 g; P < .01) or to lesions with no pacing and HFJV (4.92 ± 3.00 g; P < .01). Lesions with both pacing and HFJV had the greatest reduction in contact force standard deviation (4.35 ± 2.81 g; P < .01), confirming an additive benefit of each maneuver. Pacing and HFJV together was also associated with a reduction in the proportion of lesions with excessive maximum contact force (P < .001). DISCUSSION: Rapid pacing and HFJV additively improve catheter stability. Simultaneous pacing with HFJV further improves catheter stability over pacing or HFJV alone to optimize ablation lesions.


Subject(s)
Atrial Fibrillation , Catheter Ablation , High-Frequency Jet Ventilation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheters , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans
5.
Cell Rep ; 28(7): 1679-1689.e4, 2019 08 13.
Article in English | MEDLINE | ID: mdl-31412239

ABSTRACT

During translation, an mRNA is typically occupied by multiple ribosomes sparsely distributed across the coding sequence. This distribution, mediated by slow rates of initiation relative to elongation, ensures that they rarely collide with each other, but given the stochastic nature of protein synthesis, collision events do occur. Recent work from our lab suggested that collisions signal for mRNA degradation through no-go decay (NGD). We have explored the impact of stalling on ribosome function when NGD is compromised and found it to result in +1 frameshifting. We used reporters that limit the number of ribosomes on a transcript to show that +1 frameshifting is induced through ribosome collision in yeast and bacteria. Furthermore, we observe a positive correlation between ribosome density and frameshifting efficiency. It is thus tempting to speculate that NGD, in addition to its role in mRNA quality control, evolved to cope with stochastic collision events to prevent deleterious frameshifting events.


Subject(s)
Frameshifting, Ribosomal , Protein Biosynthesis , RNA Stability , RNA, Messenger/metabolism , Ribosomes/metabolism , Saccharomyces cerevisiae Proteins/metabolism , Saccharomyces cerevisiae/metabolism , Open Reading Frames , Quality Control , RNA, Fungal/genetics , RNA, Fungal/metabolism , RNA, Messenger/genetics , Ribosomal Proteins/genetics , Ribosomal Proteins/metabolism , Ribosomes/genetics , Saccharomyces cerevisiae/genetics , Saccharomyces cerevisiae Proteins/genetics
6.
JACC Clin Electrophysiol ; 5(5): 626-634, 2019 05.
Article in English | MEDLINE | ID: mdl-31122386

ABSTRACT

OBJECTIVES: This study sought to determine whether a radiation safety time-out reduces radiation exposure in electrophysiology procedures. BACKGROUND: Time-outs are integral to improving quality and safety. The authors hypothesized that a radiation safety time-out would reduce radiation exposure levels for patients and the health care team members. METHODS: The study was performed at the New York University Langone Health Electrophysiology Lab. Baseline data were collected for 6 months prior to the time-out. On implementation of the time-out, data were collected prospectively with analyses to be performed every 3 months. The primary endpoint was dose area product. The secondary endpoints included reference point dose, fluoroscopy time, use of additional shielding, and use of alternative imaging such as intracardiac and intravascular ultrasound. RESULTS: A total of 1,040 patient cases were included. The median dose area product prior to time-out was 18.7 Gy∙cm2, and the median during the time-out was 14.7 Gy∙cm2, representing a 21% reduction (p = 0.007). The median reference point dose prior to time-out was 163 mGy, and during the time-out was 122 mGy (p = 0.011). The use of sterile disposable protective shields and ultrasound imaging for access increased significantly during the time-out. CONCLUSIONS: A radiation safety time-out significantly reduces radiation exposure in electrophysiology procedures. Electrophysiology laboratories, as well as other areas of cardiovascular medicine using fluoroscopy, should strongly consider the use of radiation safety time-outs to reduce radiation exposure and improve safety.


Subject(s)
Electrophysiologic Techniques, Cardiac , Patient Safety , Radiation Dosage , Radiation Exposure , Aged , Aged, 80 and over , Electrophysiologic Techniques, Cardiac/methods , Electrophysiologic Techniques, Cardiac/standards , Female , Fluoroscopy/standards , Humans , Male , Prospective Studies , Radiation Exposure/prevention & control , Radiation Exposure/standards , Radiation Exposure/statistics & numerical data , Time Factors
7.
JACC Clin Electrophysiol ; 4(4): 483-490, 2018 04.
Article in English | MEDLINE | ID: mdl-30067488

ABSTRACT

OBJECTIVES: This study sought to investigate the effect of pacing mediated heart rate modulation on catheter-tissue contact and impedance reduction during radiofrequency ablation in human atria during atrial fibrillation (AF) ablation. BACKGROUND: In AF ablation, improved catheter-tissue contact enhances lesion quality and acute pulmonary vein isolation rates. Previous studies demonstrate that catheter-tissue contact varies with ventricular contraction. The authors investigated the impact of modulating heart rate on the consistency of catheter-tissue contact and its effect on lesion quality. METHODS: Twenty patients undergoing paroxysmal AF ablation received ablation lesions at 15 pre-specified locations (12 left atria, 3 right atria). Patients were assigned randomly to undergo rapid atrial pacing for either the first half or the second half of each lesion. Contact force and ablation data with and without pacing were compared for each of the 300 ablation lesions. RESULTS: Compared with lesion delivery without pacing, pacing resulted in reduced contact force variability, as measured by contact force SD, range, maximum, minimum, and time within the pre-specified goal contact force range (p < 0.05). There was no difference in the mean contact force or force-time integral. Reduced contact force variability was associated with a 30% greater decrease in tissue impedance during ablation (p < 0.001). CONCLUSIONS: Pacing induced heart rate acceleration reduces catheter-tissue contact variability, increases the probability of achieving pre-specified catheter-tissue contact endpoints, and enhances impedance reduction during ablation. Modulating heart rate to improve catheter-tissue contact offers a new approach to optimize lesion quality in AF ablation. (The Physiological Effects of Pacing on Catheter Ablation Procedures to Treat Atrial Fibrillation [PEP AF]; NCT02766712).


Subject(s)
Atrial Fibrillation/surgery , Cardiac Pacing, Artificial/methods , Catheter Ablation/methods , Heart Atria/surgery , Heart Rate/physiology , Female , Humans , Male , Middle Aged