1.
Food Chem ; 448: 139115, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38552466

ABSTRACT

G-quadruplexes (G4) have received significant attention in the field of aptasensors owing to their unique physicochemical characteristics. A dual-mode, protein-free and label-free aptamer sensor based on plasmonic colorimetry and G4 fluorescence (PC@GF-aptasensor) was proposed for ochratoxin A (OTA). Colorimetry mode was achieved through the surface plasmon resonance (SPR) effect, which related to the OTA-Apt-based G4-OTA. The fluorescence mode was reflected by the insertion of thioflavin T (ThT) into G4-OTA. The OTA could be interpreted via three readouts: (1) naked eye (LOD of 2.0 ng mL-1), (2) smartphone (LOD of 1.65 ng mL-1), and (3) spectrofluorometer (LOD of 0.93 ng mL-1). The PC@GF-aptasensor exhibited several advantages, such as a standardised recognition group, simplified operation, low background signal, and practicality. The proposed PC@GF-aptasensor integrated SPR-based multicolour interpretation and ThT-inserted fluorescence reflection to obtain a dual-mode optical biosensor, which may provide valuable insights for the development of other targets with G4-based aptamers.

2.
J Food Sci ; 88(10): 4316-4326, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37732469

ABSTRACT

A novel immunochromatography strip (ICS) based on the DNA-bridged double gold nanoparticles was established and evaluated for the dual-mode detection of ochratoxin A (OTA). For this purpose, the streptavidin was coupled with the big size of gold nanoparticle (40 nm, AuNP), the OTA monoclonal antibody and biotinylated DNA-SH were simultaneously immobilized on the small size of AuNP (20 nm), and then the enhanced ICS was self-assembled and evaluated. The dual-mode detection of semi-quantification and quantification had been achieved and performed by the proposed ICS. The LOD for semi-quantification (semi-Q-LOD) was 0.06 ng/mL by the directly naked eye (eightfold enhanced than conventional ICS). By the on-site reader, the LOD for quantification (Q-LOD) was 0.03 ng/mL (threefold enhanced), with the detection range between 0.03 and 1.2 ng/mL. The specificity, reliability, and practicability had been well represented. Furthermore, the OTA-positive results of the enhanced ICS method correlated well with those obtained by the referenced HPLC-MS/MS for the market samples. This study provided a new ICS pattern of semi-quantification and quantification for OTA contamination, which could be used as a valuable reference for improving the ICS technology and enhancing the sensitivity.

SELECTION OF CITATIONS
SEARCH DETAIL
...