Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Burns ; 50(3): 578-584, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38238240

ABSTRACT

BACKGROUND: The goal of this study is to look into the factors that lead to death in patients with necrotizing soft tissue infections(NSTIs) in the intensive care unit and create a mortality risk model. METHODS: The clinical data of 106 patients with necrotizing soft tissue infections admitted to intensive care unit(ICU) of the First Affiliated Hospital of Wenzhou Medical University between January 2008 and December 2021 were retrospectively analyzed. Univariate analysis and multivariate analysis were performed to evaluate the risk factors impacting patient mortality. The regression coefficient in binary logistic regression analysis was converted into the item score in the model, and then the model score of each patient was calculated. Finally, an ROC curve was constructed to evaluate the efficiency of the model for predicting mortality. Thirteen patients with NSTIs admitted to ICU between January 2022 and November 2022 were used to validate the model. RESULTS: The death group had 44 patients, while the survival group had 62 patients. The overall mortality was 41.5%. Binary logistic regression analysis showed that risk factors for mortality were age≥ 60 years(OR:4.419; 95%CI:1.093-17.862; P = 0.037), creatinine ≥ 132µmol/L(OR:11.166; 95%CI:2.234-55.816; P = 0.003), creatine kinase ≥ 1104 U/L(OR:4.019; 95%CI:1.134-14.250; P = 0.031), prothrombin time ≥ 24.4 s(OR:11.589; 95%CI:2.510-53.506; P = 0.002), and invasive mechanical ventilation (OR:17.404; 95%CI:4.586-66.052; P<0.000). The AUC of the model for predicting mortality was 0.940 (95% CI:0.894-0.986). When the cut-off value for the model was 4 points, the sensitivity was 95.5% and the specificity was 83.9%. CONCLUSION: The death risk model in this study for NSTIs patients in the intensive care unit shows high sensitivity and specificity. Patients with a score of ≥ 4 points have a higher risk of mortality.


Subject(s)
Burns , Sepsis , Soft Tissue Infections , Humans , Middle Aged , Soft Tissue Infections/epidemiology , Retrospective Studies , Prognosis , Intensive Care Units , ROC Curve
2.
J Mech Behav Biomed Mater ; 146: 106031, 2023 10.
Article in English | MEDLINE | ID: mdl-37639933

ABSTRACT

Spider silk is repeatedly stretched while performing biological functions. There is a close relationship between the shape change of the fibre materials and their mechanical properties. However, the effect of the deformation and interval time on the structure and tensile behaviour properties of spider silk after repeatedly stretching by given strain value has been rarely reported. Here we found that major ampullate silk (MAS) can revert its tensile behaviour independent of its previous loading history via intervals of approximately 8 s to 5 min with constant and increased elongation, respectively, after being subjected to yield and hardening regions. The true stress-true strain curve beyond a given value of true strain is independent from the previous loading history of the sample. Even after longer intervals (≥1 h), MAS can reproduce the last tensile behaviour via one stretched. Despite recognizing the development of irreversible deformations in the material when tested in air, the reversible change in tensile behaviour outside the spider silk's elastic region has rarely been observed before. MAS has at least one proper ground state that allows it to present good shape and mechanical behaviour memory in terms of longitudinal stretching, functioning as a new strategy to achieve certain tensile properties. The analysis of the true stress-true strain curves was performed from a series of loading‒unloading tests to evaluate the evolution of those mechanical parameters with the cycle number. The elastic modulus measured in the loading steps increases monotonously with increasing values of true strain reached in the cycles. In contrast, a marginal variation is found in the values of the yield stress measured in the different cycles. The memory and variation in the mechanical behaviour and performance of MAS can be accounted for through the irreversible and reversible deformation micromechanisms and its combination in which the viscoelasticity of the material plays a leading role. These findings may be helpful to guide the biomimetic design of novel fibre materials such as spider silk gut via artificially stretching spider silk glands.


Subject(s)
Biomimetics , Silk , Elastic Modulus
SELECTION OF CITATIONS
SEARCH DETAIL
...