Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 20(4)2020 Feb 14.
Article in English | MEDLINE | ID: mdl-32075021

ABSTRACT

The fused silica cylindrical resonator is a type of axisymmetric resonator that can be used for Coriolis vibratory gyroscopes. Although the resonant frequency, frequency mismatch, and Q factor are natural properties of the resonator, they can change with temperature. Therefore, the temperature drift severely limits the detection accuracy and bias stability of the gyroscope. In this paper, the influence of temperature variation on the vibrational characteristics of fused silica cylindrical resonators was investigated. Experiments were performed on a fused silica cylindrical resonator coated with Cr/Au films. It was shown that at the temperature range from 253.15 K to 353.15 K, the resonant frequency linearly increased with temperature, the frequency mismatch remained unchanged, and the Q factor gradually increased till about 333.15 K, when it began to decrease. Meanwhile, the change of thermoelastic damping with temperature may dominate the variation of Q factor at the temperature range from 253.15 K to 353.15 K. This phenomenon was theoretically analyzed and the variation trends of results were consistent with the theoretical analysis. This study indicates that, for the fused silica cylindrical resonator, to discover the influence of temperature variation on the resonant frequency, frequency mismatch, and Q factor, there are certain rules to follow and repeat. The relationship between temperature and frequency can be established, which provides the feasibility of using self-calibration based on temperature characteristics of the resonator for temperature drift compensations. Additionally, there is an optimum temperature that may improve the performance of the Coriolis vibratory gyroscope with the fused silica cylindrical resonator.

2.
Sensors (Basel) ; 20(1)2020 Jan 05.
Article in English | MEDLINE | ID: mdl-31948044

ABSTRACT

The Coriolis Vibratory Gyroscopes are a type of sensors that measure angular velocities through the Coriolis effect. The resonator is the critical component of the CVGs, the vibrational characteristics of which, including the resonant frequency, frequency mismatch, Q factor, and Q factor asymmetry, have a great influence on the performance of CVG. The frequency mismatch and Q factor of the resonator, in particular, directly determine the precision and drift characteristics of the gyroscope. Although the frequency mismatch and Q factor are natural properties of the resonator, they can change with external conditions, such as temperature, pressure, and external forces. In this paper, the influence of electrostatic forces on the vibrational characteristics of the fused silica cylindrical resonator is investigated. Experiments were performed on a fused silica cylindrical resonator coated with Cr/Au films. It was shown that the resonant frequency, frequency mismatch, and the decay time slightly decreased with electrostatic forces, while the decay time split increased. Lower capacitive gaps and larger applied voltages resulted in lower frequency mismatch and lower decay time. This phenomenon was theoretically analyzed, and the variation trends of results were consistent with the theoretical analysis. This study indicates that, for fused silica cylindrical resonator with electrostatic transduction, the electrostatic influence on the Q factor and frequency, although small, should be considered when designing the capacitive gap and choosing bias voltages.

3.
Plant Sci ; 289: 110280, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31623773

ABSTRACT

MADS-box genes encode transcription factors involved in the control of many important developmental processes, especially the flower development of angiosperms. Analysis on gene regulatory relationship between MADS-box genes is useful for understanding the molecular mechanism of flower development. In this study, we focused on the regulatory relationship between MADS-box transcription factors APETALA1 (AP1) and PISTILLATA(PI)/DEFICIENS (DEF) in birch. We found that BpPI was an authentic target gene of BpAP1, and BpAP1 activated the expression of BpPI via directly binding to the CArG box motif. Functional analysis of BpPI showed that overexpression of BpPI may delay flowering via restricting flowering activators, in which BpAP1 was significantly down-regulated. We further investigated the regulatory of BpAP1 by BpPI, and found that BpPI could directly bind to the promoter of BpAP1 to restrict BpAP1 expression. In addition, we also found that BpPI could interact with its hypothetical partner BpDEF to co-regulate BpAP1 in birch. Our results suggested that overexpression of BpPI may delay flowering via restricting flowering activators, and there is a negative feedback loop between BpAP1 and BpPI/BpDEF heterodimer in birch. Our results will bring new evidences for further analysis of the molecular mechanism of flower formation in plants that produced unisexual flowers.


Subject(s)
Betula/genetics , Gene Expression Regulation, Plant , MADS Domain Proteins/genetics , Plant Proteins/genetics , Betula/growth & development , Flowers/genetics , Flowers/growth & development , Hybridization, Genetic , MADS Domain Proteins/metabolism , Plant Proteins/metabolism
4.
Sensors (Basel) ; 19(13)2019 Jul 02.
Article in English | MEDLINE | ID: mdl-31269769

ABSTRACT

Fused silica cylindrical resonant gyroscope (CRG) is a novel high-precision solid-wave gyroscope, whose performance is primarily determined by the cylindrical resonator's frequency split and quality factor (Q factor). The laser Doppler vibrometer (LDV) is extensively used to measure the dynamic behavior of fused silica cylindrical resonators. An electrical method was proposed to characterize the dynamic behavior of the cylindrical resonator to enhance the measurement efficiency and decrease the equipment cost. With the data acquisition system and the designed signal analysis program based on LabVIEW software, the dynamic behavior of the fused silica cylindrical resonator can be analyzed automatically and quickly. We compared all the electrical measurement results with the optical detection by LDV, demonstrating that the fast Fourier transform (FFT) result of the resonant frequency measured by the electrical method was 0.12 Hz higher than that with the optical method. Thus, the frequency split measured by the electrical and optical methods was the same in 0.18 Hz, and the measurement of the Q factor was basically the same in 730,000. We conducted all measurements under the same operation condition, and the optical method was used as a reference, demonstrating that the electrical method could characterize the dynamic behavior of the fused silica cylindrical resonator and enhance the measurement efficiency.

SELECTION OF CITATIONS
SEARCH DETAIL
...