Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Ophthalmol ; 9(5): 699-702, 2016.
Article in English | MEDLINE | ID: mdl-27275424

ABSTRACT

AIM: To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant. METHODS: This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained. RESULTS: There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon, P<0.001) after the operation. The range of the cylindrical error was reduced from 1.5-3.95 D (keratometric) preoperatively to 0.00-1.46 D (subjective refraction transposed to corneal plane) postoperatively. CONCLUSION: Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.

2.
Clin Exp Ophthalmol ; 36(2): 156-8, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18352872

ABSTRACT

BACKGROUND: The ability to perform biometry accurately on a dilated pupil can greatly facilitate the efficiency of a cataract service as it can be done on the day of surgery. The purpose of this study was to assess the repeatability of axial length (AL) calculations in undilated pupils and measure the difference in predicted and actual refractive outcomes in dilated pupils compared with undilated pupils. METHODS: First, intraobserver repeatability was assessed by taking two consecutive recordings of AL using applanation A-scan ultrasonography in undilated pupils in 21 eyes. The mean AL for each eye was compared with a measurement made following pupil dilatation. Second, we audited the mean spherical equivalent refractive errors following routine cataract surgery in 38 patients with undilated pupils and 36 patients with dilated pupils. RESULTS: The mean difference in intraobserver measurements was -0.05 mm (standard deviation [SD] 0.15) with pupils undilated. Following pupil dilatation, the mean dilated AL differed from the mean undilated AL reading by only 0.03 mm (P > 0.05). The mean differences between planned and actual refractive error were 0.71D (SD 0.54) and 0.55D (SD 0.41) in dilated and undilated patients, respectively. This was not statistically significant (P > 0.05). The range of differences between target and actual refraction was -1.45D to 2.70D for undilated patients and -1.88D to 1.18D in dilated patients. CONCLUSION: Although there was a greater spread of postoperative refractive errors in the dilated group, there were no statistically or clinically significant differences in postoperative refractive errors between the two categories of patients. Our study shows that applanation biometry may be safely performed for the purpose of cataract surgery after pupil dilatation.


Subject(s)
Biometry/methods , Cataract Extraction/methods , Lenses, Intraocular/standards , Mydriatics , Pupil/drug effects , Refraction, Ocular/physiology , Cataract Extraction/adverse effects , Humans , Mydriatics/administration & dosage , Observer Variation , Ophthalmic Solutions , Predictive Value of Tests , Refractive Errors/etiology , Refractive Errors/physiopathology , Refractive Errors/prevention & control , Statistics, Nonparametric