Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
2.
Colorectal Dis ; 18(7): O236-42, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27154050

ABSTRACT

AIM: The objective of the study was to evaluate the association between the neutrophil-to-lymphocyte ratio (NLR) and the occurrence of perioperative complications in patients undergoing colorectal surgery. METHOD: A retrospective cohort study was conducted of patients who underwent resection for suspected or confirmed colorectal cancer from 2004 to 2012. Patient cohorts with a high vs low NLR were defined by receiver operating characteristic curve analysis. Univariate and multivariate logistic regression was used to determine whether patients with elevated NLR were more likely to suffer perioperative complications. RESULTS: In all, 583 patients were included. A preoperative NLR greater than or equal to 2.3 was significantly associated with a major perioperative complication (OR 2.52, 95% CI 1.26-5.01). On multivariate analysis, a high NLR (OR 2.25, 95% CI 1.12-4.52) and Charlson Comorbidity Index ≥ 3 (OR 4.55, 95% CI 2.17-9.56) were significantly related to major morbidity. No relationships were found between an elevated preoperative NLR and complication type, although there was a trend towards the occurrence of anastomotic leakage. CONCLUSION: Preoperative NLR ≥ 2.3 may be a risk factor for major surgical complications following colorectal resection. Further study is needed to validate this threshold and evaluate the clinical implications of these findings.


Subject(s)
Digestive System Surgical Procedures/adverse effects , Lymphocytes/cytology , Postoperative Complications/etiology , Adult , Aged , Aged, 80 and over , Colon/surgery , Digestive System Surgical Procedures/methods , Female , Humans , Leukocyte Count , Lymphocyte Count , Male , Middle Aged , Multivariate Analysis , Neutrophils , Predictive Value of Tests , Preoperative Period , ROC Curve , Rectum/surgery , Retrospective Studies , Risk Factors , Young Adult
3.
Colorectal Dis ; 16(10): 788-93, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24836397

ABSTRACT

AIM: This study aimed to evaluate both the short- and long-term outcomes associated with colonic stenting as a bridge to surgery in patients with obstructing adenocarcinoma of the colon. METHOD: Patients with potentially curable acute left-sided colonic obstruction treated with stenting as a bridge to surgery (n = 28) or with emergency surgical resection (n = 39) from January 1998 to December 2008 were identified from a prospectively maintained database. Short-term data on postoperative mortality, morbidity, necessity of intensive care and length of hospital stay were compared. Overall survival and disease-free survival were also analysed. RESULTS: Patients in the two study arms had similar demographic profiles. Those receiving preoperative stenting had a higher likelihood of a laparoscopic resection (P < 0.001). The emergency surgery group had a higher rate of postoperative complications (P = 0.024), rate of intensive care unit admission (P = 0.013) and longer total length of hospital stay (9 vs 12 days, P = 0.001). With a median follow-up of 26.5 and 31.3 months for the stenting and surgical resection groups, there was no difference in overall and disease-free survival (overall survival 30 vs 31 months, P = 0.858; disease-free survival 13 vs 12 months, P = 0.989). There was no difference in the rate of systemic recurrence (8 vs 13, P = 0.991). CONCLUSION: Stenting as a bridge to surgery is a safe strategy for acute left-sided colonic obstruction with improved short-term outcome and comparable long-term oncological results.


Subject(s)
Adenocarcinoma/surgery , Colonic Neoplasms/surgery , Intestinal Obstruction/therapy , Preoperative Care , Stents , Adenocarcinoma/complications , Adenocarcinoma/pathology , Adult , Aged , Aged, 80 and over , Colectomy/adverse effects , Colon, Descending , Colonic Neoplasms/complications , Colonic Neoplasms/pathology , Critical Care , Disease-Free Survival , Emergencies , Female , Humans , Intestinal Obstruction/etiology , Length of Stay , Male , Middle Aged , Retrospective Studies , Stents/adverse effects , Survival Rate , Time Factors , Treatment Outcome
4.
Int J Oral Maxillofac Surg ; 40(6): 644-6, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21208781

ABSTRACT

Arterial pseudoaneurysms are rare in oral and maxillofacial surgery, but when they occur, quick recognition and management is necessary to avoid devastating consequences. The authors report a case of a pseudoaneurysm of the external carotid artery that developed after open reduction and internal fixation of a mandibular condyle fracture.


Subject(s)
Carotid Artery Injuries/etiology , Carotid Artery, External/pathology , Mandibular Condyle/injuries , Mandibular Fractures/complications , Angiography , Embolization, Therapeutic/methods , Follow-Up Studies , Fracture Fixation, Internal , Humans , Male , Maxillary Artery/pathology , Temporal Arteries/pathology , Tomography, X-Ray Computed , Young Adult
6.
J Oral Maxillofac Surg ; 58(11): 1263-9, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11078138

ABSTRACT

PURPOSE: The efficacy of bioresorbable fixation has recently been described in the treatment of cranial vault deformities and in midfacial trauma. However, little to no data exist regarding its use in load-bearing areas. The purpose of this study is to analyze and compare the treatment of mandibular fractures by using a bioresorbable fixation system with a conventional titanium system in a canine model. MATERIALS AND METHODS: Four adult beagles constituted the experimental group (A), and 2 beagles constituted the control group (B). Both groups underwent extraoral iatrogenic left mandibular angle osteotomies/fractures and open reduction and internal fixation by use of a bioresorbable fixation system (A) or a titanium fixation system (B). All operated animals were allowed to function immediately. Lateral skull radiographs were obtained preoperatively, immediately postoperatively after reduction, and at 3- and 6-month intervals. Preoperative and 6-month follow-up bite registrations were taken. At the 3-month interval, 1 animal from the experimental group was killed, and at 6 months the remaining animals were killed for morphologic, radiographic, and histologic analysis of the fractured interface and screw sites. RESULTS: Morphologically, in the bioresorbable group, there was no clinical evidence of 1) intraoral/ extraoral incisional dehiscence of wound infection; 2) deviation of the occlusion from maximum intercuspation; 3) intraoral/extraoral palpability of the device; 4) mobility of the fractured segments on manual manipulation; or 5) malunion as visualized at the time of sacrifice. All bioresorbable plates were clinically absent after 6 months and associated with adequate fixation and healing. Adequate restoration of function was achieved in both groups, with all of the animals showing weight gain. Radiographically, good alignment of the inferior border was seen, and histologically bony union was apparent in all specimens. CONCLUSIONS: This bioresorbable fixation system is effective in the treatment of mandibular angle fractures in a dog model, despite being placed in a load-bearing region.


Subject(s)
Absorbable Implants , Bone Screws , Fracture Fixation, Internal/instrumentation , Jaw Fixation Techniques/instrumentation , Mandibular Fractures/surgery , Animals , Biocompatible Materials , Dogs , Female , Implants, Experimental , Lactic Acid , Models, Animal , Polyglycolic Acid , Polylactic Acid-Polyglycolic Acid Copolymer , Polymers , Titanium
10.
J Craniofac Surg ; 9(5): 468-71, 1998 Sep.
Article in English | MEDLINE | ID: mdl-9780918

ABSTRACT

Parotid gland tumors, especially those of the accessory parotid gland, are rare in infancy. Although infantile hemangiomas have been frequently reported as a cause of parotid gland tumors, their association with the accessory parotid gland has not been reported. This article describes the presentation of a hemangioma of the accessory parotid gland in an infant. Review of the literature and treatment methods are discussed.


Subject(s)
Hemangioma, Capillary/pathology , Parotid Neoplasms/pathology , Female , Humans , Infant , Magnetic Resonance Imaging
11.
Article in English | MEDLINE | ID: mdl-9619666

ABSTRACT

Dermal grafts have been described for a variety of applications, including preprosthetic surgery, reconstructive surgery, and temporomandibular joint surgery. Several reports have described the procedural techniques for acquiring a dermal graft. The surgical technique for harvesting a dermal graft with the use of the dermabrading diamond fraise bur is described. The use of the diamond fraise bur offers many unique surgical advantages: it allows minimal damage to the dermal layer; the healing surface is smooth, cosmetic, homogenous, and devoid of scratches or debris; an adequate graft of uniform thickness is obtained; the technique allows access to a variety of donor sites; and minimal patient postoperative donor site morbidity. The use of this technique provides a simple, cosmetic approach to obtaining an adequate dermal graft for temporomandibular joint reconstructive procedures, while minimizing the potential complications associated with other commonly used techniques.


Subject(s)
Dermabrasion/instrumentation , Skin Transplantation/methods , Temporomandibular Joint Disc/surgery , Adipose Tissue/surgery , Dermabrasion/methods , Diamond , Epidermis/surgery , Equipment Design , Humans , Skin Transplantation/instrumentation
12.
J Craniofac Surg ; 8(2): 110-5, 1997 Mar.
Article in English | MEDLINE | ID: mdl-10332277

ABSTRACT

We describe early experience using a polymeric bioresorbable bone fixation system in a consecutive series of eight pediatric patients for the correction of craniofacial malformations. Indications for surgical treatment included craniosynostosis (7) and encephalocele (1). All patients underwent bifrontal craniotomies with cranial vault or orbital reconstruction or both. Segments were then stabilized using bioresorbable fixation systems. Patients were evaluated pre- and postoperatively clinically and with radiographs and photographs. Mean follow-up was 4.5 months, with a minimum follow-up of 3 months. In seven of eight patients, there was no incidence of infection, extrusion, exposure, erythema, instability of the advanced segments, relapse, hematoma, seroma formation, or adverse inflammatory reaction. One patient experienced difficulty with respect to system imperfections (i.e., drill holes after tapping were too large for screws). This study demonstrated the efficacy of bioresorbable plates and screws for the growing pediatric craniofacial patient; excellent short-term results were achieved. Prospective studies and longer longitudinal follow-up of larger numbers of patients are desirable to confirm these findings.


Subject(s)
Absorbable Implants , Bone Plates , Bone Screws , Craniosynostoses/surgery , Biocompatible Materials , Biodegradation, Environmental , Child , Child, Preschool , Craniotomy/instrumentation , Encephalocele/surgery , Follow-Up Studies , Humans , Infant , Polymers/chemistry , Reoperation , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...