Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Sci Rep ; 11(1): 9266, 2021 04 29.
Article in English | MEDLINE | ID: mdl-33927217

ABSTRACT

Modifications of the myocardial architecture can cause abnormal electrical activity of the heart. Fibro-fatty infiltrations have been implicated in various cardiac pathologies associated with arrhythmias and sudden cardiac death, such as arrhythmogenic right ventricular cardiomyopathy (ARVC). Here, we report the development of an MRI protocol to observe these modifications at 9.4 T. Two fixed ex vivo human hearts, one healthy and one ARVC, were imaged with an Iterative decomposition with echo asymmetry and least-square estimations (IDEAL) and a magnetization transfer (MT) 3D sequences. The resulting fat fraction and MT ratio (MTR) were analyzed and compared to histological analysis of the three regions ("ARVC triangle") primarily involved in ARVC structural remodeling. In the ARVC heart, high fat content was observed in the "ARVC triangle" and the superimposition of the MTR and fat fraction allowed the identification of fibrotic regions in areas without the presence of fat. The healthy heart exhibited twice less fat than the ARVC heart (31.9%, 28.7% and 1.3% of fat in the same regions, respectively). Localization of fat and fibrosis were confirmed by means of histology. This non-destructive approach allows the investigation of structural remodeling in human pathologies where fibrosis and/or fatty tissue infiltrations are expected to occur.


Subject(s)
Adipose Tissue/diagnostic imaging , Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Heart/diagnostic imaging , Adipose Tissue/pathology , Adult , Arrhythmogenic Right Ventricular Dysplasia/pathology , Fibrosis , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Male
2.
Rev Sci Instrum ; 90(7): 073705, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31370474

ABSTRACT

The characterization of buried nanoscale structures nondestructively is an important challenge in a number of applications, such as defect detection and metrology in the semiconductor industry. A promising technique is Subsurface Scanning Probe Microscopy (SSPM), which combines ultrasound with Atomic Force Microscopy (AFM). Initially, SSPM was used to measure the viscoelastic contrast between a subsurface feature and its surrounding medium. However, by increasing the ultrasonic frequency to >1 GHz, it has been shown that SSPM can also measure acoustic impedance based contrasts. At these frequencies, it becomes difficult to reliably couple the sound into the sample such that the AFM is able to pick up the scattered sound field. The cause is the existence of strong acoustic resonances in the sample, the transducer, and the coupling layer-the liquid layer used to couple the sound energy from the transducer into the sample-in combination with the nonlinearity of the tip-sample interaction. Thus, it is essential to control and measure the thickness of the coupling layer with nanometer accuracy. Here, we present the design of a mechanical clamp to ensure a stable acoustic coupling. Moreover, an acoustic method is presented to measure the coupling layer thickness in real-time. Stable coupling layers with thicknesses of 700 ± 2 nm were achieved over periods of 2-4 h. Measurements of the downmixed AFM signals showed stable signal intensities for >1 h. The clamp and monitoring method introduced here makes scattering based SSPM practical, robust, and reliable and enables measurement periods of hours.

3.
Phys Med Biol ; 62(4): 1208-1224, 2017 02 21.
Article in English | MEDLINE | ID: mdl-28114116

ABSTRACT

The use of magnetic resonance (MR) thermometry for the monitoring of thermal ablation is rapidly expanding. However, this technique remains challenging for the monitoring of the treatment of cardiac arrhythmia by radiofrequency ablation due to the heart displacement with respiration and contraction. Recent studies have addressed this problem by compensating in-plane motion in real-time with optical-flow based tracking technique. However, these algorithms are sensitive to local variation of signal intensity on magnitude images associated with tissue heating. In this study, an optical-flow algorithm was combined with a principal component analysis method to reduce the impact of such effects. The proposed method was integrated to a fully automatic cardiac MR thermometry pipeline, compatible with a future clinical workflow. It was evaluated on nine healthy volunteers under free breathing conditions, on a phantom and in vivo on the left ventricle of a sheep. The results showed that local intensity changes in magnitude images had lower impact on motion estimation with the proposed method. Using this strategy, the temperature mapping accuracy was significantly improved.


Subject(s)
Catheter Ablation , Heart/physiology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Movement/physiology , Optical Imaging/methods , Thermometry/methods , Algorithms , Animals , Healthy Volunteers , Humans , Phantoms, Imaging , Principal Component Analysis , Respiration , Sheep
4.
NMR Biomed ; 25(1): 35-43, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21732459

ABSTRACT

Catheter ablation using radio frequency (RF) has been used increasingly for the treatment of cardiac arrhythmias and may be combined with proton resonance frequency shift (PRFS) -based MR thermometry to determine the therapy endpoint. We evaluated the suitability of two different MR thermometry sequences (TFE and TFE-EPI) and three blood suppression techniques. Experiments were performed without heating, using an optimized imaging protocol including navigator respiratory compensation, cardiac triggering, and image processing for the compensation of motion and susceptibility artefacts. Blood suppression performance and its effect on temperature stability were evaluated in the ventricular septum of eight healthy volunteers using multislice double inversion recovery (MDIR), motion sensitized driven equilibrium (MSDE), and inflow saturation by saturation slabs (IS). It was shown that blood suppression during MR thermometry improves the contrast-to-noise ratio (CNR), the robustness of the applied motion correction algorithm as well as the temperature stability. A gradient echo sequence accelerated by an EPI readout and parallel imaging (SENSE) and using inflow saturation blood suppression was shown to achieve the best results. Temperature stabilities of 2 °C or better in the ventricular septum with a spatial resolution of 3.5 × 3.5 × 8mm(3) and a temporal resolution corresponding to the heart rate of the volunteer, were observed. Our results indicate that blood suppression improves the temperature stability when performing cardiac MR thermometry. The proposed MR thermometry protocol, which optimizes temperature stability in the ventricular septum, represents a step towards PRFS-based MR thermometry of the heart at 3 T.


Subject(s)
Heart/physiology , Magnetic Resonance Imaging/methods , Temperature , Humans , Signal-To-Noise Ratio
5.
Med Phys ; 38(1): 272-82, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21361196

ABSTRACT

PURPOSE: High-intensity focused ultrasound guided by magnetic resonance imaging has been extensively evaluated during the past decade as a clinical alternative for thermal ablation of tumor tissue. However, the maximal ablation volume is limited by the extensive treatment duration resulting from the small size of the focal point as compared to the average tumor size. Volumetric sonication has been shown to efficiently enlarge the ablated volume per sonication, but remains limited by the temperature increase induced in the skin and fat layers. In this study, multiplane MR thermometry is proposed for monitoring the near-field temperature rise in order to prevent related unintended thermal damage. METHODS: The method was evaluated by performing sonications in the thigh muscle of 11 pigs maintained under general anesthesia. Volumetric ablations were performed by steering the focal point along trajectories consisting of multiple outward-moving concentric circles. Near-field heating was characterized with MR temperature maps and thermal dose maps. The results from the MR measurements were compared to simulations. RESULTS: In this study, the measured maximum temperature rise was found to correlate linearly with the surface energy density within the near field of the beam path with a slope of 4.2 K mm2/J. This simple linear model appears to be almost independent of the trajectory pattern and the sonication depth. The safety limit to avoid lethal damage of the subcutaneous tissues of the porcine thigh was identified to be an absolute temperature of 50 degrees C, corresponding to a surface energy density of 2.5 J/mm2 at 1.2 MHz. CONCLUSIONS: A linear relationship can be established to estimate the temperature increase based on the chosen power prior to ablation, thereby providing an a priori safety check for possible excessive near-field heating using a known surface energy density threshold. This method would also give the clinician the possibility to abort the sonication should excessive near-field temperature rise be seen before fat layer damage or skin burns are inflicted.


Subject(s)
High-Intensity Focused Ultrasound Ablation/methods , Hot Temperature , Magnetic Resonance Imaging , Animals , High-Intensity Focused Ultrasound Ablation/adverse effects , Hyperthermia, Induced , Muscles/surgery , Safety , Sonication , Swine
6.
JBR-BTR ; 92(1): 8-12, 2009.
Article in English | MEDLINE | ID: mdl-19358479

ABSTRACT

Imaging in cancer has moved in the last twenty years from morphological detection of diseases to characterization and categorization of different subtypes of tumors. Functional information, based on dynamic contrast-enhanced imaging of tissue perfusion and evaluation of water diffusion, tissue oxygenation, capillary permeability or lymphatic drainage, plays a major role in that field.The next coming steps will concern the differentiation of biological behaviour of tumors according to their phenotypes by identifying specific surface receptors or products of synthesis.These developments allowing an in vivo identification of the tumor biological singularities is a tremendous progress in the management of cancer at the step of diagnosis but, more importantly, to assess the most appropriated treatment to each tumor type. At the same time, minimally invasive methods of treatment of tumors have also developed, mainly in the field of thermotherapies. Ablation of tumors using radiofrequency is now used in clinics as a new standard within the liver and as a promising additional option in many other organs as kidney, lung and bone. High intensity focused ultrasound (HIFU) showed more restricted developments in clinics, mainly applied to prostatic cancer, because of many technical barriers. We believe that magnetic resonance (MR) imaging and MR-guided HIFU (MRgHIFU) have a great potential in that field due to the capacity of MR imaging to monitor temperature changes for an optimal heat deposition and for an optimal safety. This technique has already gained recognition for the treatment of uterine leiomyomas. But it has still to prove its efficacy in treatment of malignant tumors. This review will focus on some recent developments in molecular characterisation of tumors using MR imaging and in technical improvements necessary for accurate application of MRgHIFU in cancer.


Subject(s)
Magnetic Resonance Imaging/methods , Monitoring, Intraoperative/methods , Neoplasms/diagnosis , Neoplasms/therapy , Ultrasonic Therapy/methods , Catheter Ablation/methods , Humans , Ultrasound, High-Intensity Focused, Transrectal/methods
7.
Magn Reson Med ; 61(6): 1494-9, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19353650

ABSTRACT

MR-thermometry allows monitoring of the local temperature evolution during minimally invasive interventional therapies. However, for the particular case of MR-thermometry in the human breast, magnetic field variations induced by the respiratory cycle lead to phase fluctuations requiring a suitable correction strategy to prevent thermometry errors. For this purpose a look-up-table-based multibaseline approach as well as a model-based correction algorithm were applied to MR-thermometry to correct for the periodic magnetic field changes. The proposed correction method is compatible with a variety of sensors monitoring the current respiratory state. The ability to remove phase artefacts during MR-thermometry of the human breast was demonstrated experimentally in five healthy volunteers during 3 min of free-breathing using pencil-beam navigators for respiratory control. An increase of 170-530% in temperature precision was observed for the look-up-table-based approach, whereas a further improvement by 16-36% could be achieved by applying the extended model-based correction.


Subject(s)
Artifacts , Body Temperature/physiology , Breast/physiology , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Respiratory Mechanics , Thermography/methods , Adult , Algorithms , Female , Humans , Image Interpretation, Computer-Assisted/methods , Online Systems , Reproducibility of Results , Sensitivity and Specificity , Young Adult
8.
J Radiol ; 88(11 Pt 2): 1787-800, 2007 Nov.
Article in French | MEDLINE | ID: mdl-18065943

ABSTRACT

Many techniques of thermotherapy have emerged over the last several years in the field of oncology using different types of physical agents, including ultrasound. Only ultrasound can target deep seated lesions non-invasively without need for percutaneous probe insertion. Depending on their utilization, it is possible to select either thermal effects, in a continuous mode, at low temperature (allowing thermo-induced biological effects) or at high temperature (allowing thermoablation), or mechanical effects, in a pulsed mode, at low energy level (allowing biological effects) or at high energy levels (histotripsy). Thermoablation by focused ultrasound is now developing fast for applications in many organs. It gained a well defined role for the treatment of prostatic cancer and uterine leiomyoma but needs to be better evaluated in other organs such as the breast. Treatment of abdominal tumors must still be considered as experimental as long as problems related to acoustic interfaces (produced by ribs and gas) and movement correction are not resolved. Biological applications of focused ultrasound are currently being explored and have a great long term potential.


Subject(s)
Ultrasonic Therapy/methods , Abdominal Neoplasms/therapy , Breast Neoplasms/therapy , Electrocoagulation/methods , Female , Humans , Male , Prostatic Neoplasms/therapy , Uterine Neoplasms/therapy
9.
Article in English | MEDLINE | ID: mdl-18044595

ABSTRACT

Magnetic Resonance (MR) temperature mapping can be used to monitor temperature changes during minimally invasive thermal therapies. However, MR-thermometry contains artefacts caused by phase errors induced by organ motion in inhomogeneous magnetic fields. This paper proposes a novel correction strategy based on a Principal Component Analysis (PCA) to estimate magnetic field perturbation assuming a linear magnetic field variation with organ displacement. The correction method described in this paper consists of two steps: a magnetic field perturbation model is computed in a learning step; subsequently, during the intervention, this model is used to reconstruct the magnetic field perturbation corresponding to the actual organ position which in turns allow computation of motion corrected thermal maps.


Subject(s)
Abdomen/physiology , Algorithms , Body Temperature/physiology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Thermography/methods , Data Interpretation, Statistical , Humans , Principal Component Analysis , Reproducibility of Results , Sensitivity and Specificity
10.
Int J Hyperthermia ; 21(6): 515-31, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16147437

ABSTRACT

Continuous, real-time, 3D temperature mapping during a hyperthermic procedure may provide (i) enhanced safety by visualizing temperature maps in and around the treated region, (ii) improved efficiency by adapting local energy deposition with feedback coupling algorithms and (iii) therapy end-points based on the accumulated thermal dose. Non-invasive mapping of temperature changes can be achieved with MRI and may be based on temperature dependent MRI parameters. The excellent linearity of the temperature dependency of the proton resonance frequency (PRF) and its near-independence with respect to tissue type make the PRF-based methods the preferred choice for many applications, in particular at mid- to-high field strength (> or =0.5 T). The PRF methods employ RF-spoiled gradient echo imaging methods and incorporate fat suppression techniques for most organs. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 s and a spatial resolution of approximately 2 mm is feasible for immobile tissues. Special attention is paid to methods for reducing artifacts in MR temperature mapping caused by intra-scan and inter-scan motion and motion and temperature-induced susceptibility effects in mobile tissues. Real-time image processing and visualization techniques, together with accelerated MRI acquisition techniques, are described because of their potential for therapy guidance.


Subject(s)
Hyperthermia, Induced , Magnetic Resonance Imaging , Temperature , Humans , Mathematics , Neoplasms/diagnostic imaging , Neoplasms/pathology , Radiography , Water/chemistry
11.
Mol Imaging ; 2(1): 11-7, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12926233

ABSTRACT

Spatial and temporal control of transgene expression is one of the major prerequisites of efficient gene therapy. Recently, a noninvasive, physical approach has been presented based on local heat in combination with a heat-sensitive promoter. This strategy requires tight temperature control in vivo. Here, we use MRI-guided focused ultrasound (MRI-FUS) with real-time feedback control on a whole-body clinical MRI system for a completely automatic execution of a predefined temperature-time trajectory in the focal point. Feasibility studies on expression control were carried out on subcutaneously implanted rat tumors. A stable modified C6 glioma cell line was used carrying a fused gene coding for thymidine kinase (TK) and green fluorescent protein (GFP) under control of the human heat-shock protein 70 (HSP70) promoter. In vitro studies showed strong induction of the TK-GFP gene expression upon heat shock under various conditions and localization of the protein product in the nucleus. In vivo tumors were subjected to a 3-min temperature elevation using MRI-FUS with a constant temperature, and were analysed 24 hr after the heat shock with respect to GFP fluorescence. Preliminary results showed strong local induction in regions heated above 40 degrees C, and a good correspondence between temperature maps at the end of the heating period and elevated expression of TK-GFP.


Subject(s)
Gene Expression , Genetic Therapy , Magnetic Resonance Imaging/methods , Animals , Green Fluorescent Proteins , HSP70 Heat-Shock Proteins/genetics , Humans , In Vitro Techniques , Luminescent Proteins/genetics , Magnetic Resonance Imaging/instrumentation , Promoter Regions, Genetic , Rats , Recombinant Fusion Proteins/genetics , Temperature , Thymidine Kinase/genetics , Transfection , Tumor Cells, Cultured
12.
J Gene Med ; 5(4): 333-42, 2003 Apr.
Article in English | MEDLINE | ID: mdl-12692867

ABSTRACT

BACKGROUND: Among the techniques used to induce and control gene expression, a non-invasive, physical approach based on local heat in combination with a heat-sensitive promoter represents a promising alternative but requires accurate temperature control in vivo. MRI-guided focused ultrasound (MRI-FUS) with real-time feedback control allows automatic execution of a predefined temperature-time trajectory. The purpose of this study was to demonstrate temporal and spatial control of transgene expression based on a well-defined local hyperthermia generated by MRI-FUS. METHODS: Expression of the green fluorescent protein (GFP) marker gene was used. Two cell lines were derived from C6 glioma cells. The GFP expression of the first one is under the control of the CMV promoter, whereas it is under the control of the HSP70 promoter in the second one and thus inducible by heat. Subcutaneous tumours were generated by injection in immuno-deficient mice and rats. Tumours were subjected to temperatures varying from 42 to 50 degrees C for 3 to 25 min controlled by MRI-FUS and analyzed 24 h after the heat-shock. Endogenous HSP70 expression and C6 cell distribution were also analyzed. RESULTS: The results demonstrate strong expression at 50 degrees C applied during a short time period (3 min) without affecting cell viability. Induced expression was also clearly shown for temperature in the range 44-48 degrees C but not at 42 degrees C. CONCLUSIONS: Heating with MRI-FUS allows a tight and non-invasive control of transgene expression in a tumour.


Subject(s)
Gene Expression Regulation , Hot Temperature , Magnetic Resonance Imaging/methods , Promoter Regions, Genetic/genetics , Ultrasonography/methods , Animals , Glioma/genetics , Glioma/pathology , HSP70 Heat-Shock Proteins/genetics , Heat-Shock Response/genetics , Humans , Hyperthermia, Induced , Mice , Mice, Mutant Strains , Neoplasms, Connective Tissue/genetics , Neoplasms, Connective Tissue/pathology , Neoplasms, Connective Tissue/secondary , Rats , Rats, Wistar , Time Factors , Transgenes , Tumor Cells, Cultured
13.
Magn Reson Med ; 45(1): 128-37, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11146494

ABSTRACT

Displacement of tissue during MRI-controlled hyperthermia therapy can cause significant problems. Errors in calculated temperature may result from motion-related image artifacts and inter-image object displacement, leading to incorrect spatial temperature reference. Here, cyclic navigator echoes were incorporated in rapid gradient-echo MRI sequences, used for temperature mapping based on the proton resonance frequency. On-line evaluation of navigator information was used in three ways. First, motion artifacts were minimized in echo-shifted (TE > TR) gradient-echo images using the phase information of the navigator echo. Second, navigator profiles were matched for a quantitative evaluation of displacement. Together with a novel processing method, this information was employed to correct the reference temperature maps, thereby avoiding persistence of motion-related temperature errors throughout the hyperthermic period. Third, on-line visualization of displacement, together with temperature maps and thermal dose images, was developed, allowing physician intervention at all times. Examples are given of on-line corrections during hyperthermia procedures with focused ultrasound and radiofrequency heat sources. Magn Reson Med 45:128-137, 2001.


Subject(s)
Hyperthermia, Induced , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Online Systems , Animals , Artifacts , Body Temperature , In Vitro Techniques , Male , Movement , Rats , Rats, Wistar
14.
Neuroimaging Clin N Am ; 11(4): 737-47, xi, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11995428

ABSTRACT

MR image-guided focused ultrasound (FUS) provides an entirely noninvasive approach for local thermal therapies. MR imaging allows target definition and continuous temperature mapping. Therefore, the heating procedure can be controlled spatially and temporally based on automatic feedback to the FUS apparatus. Phased-array ultrasound technology will further help the development. MR imaging/FUS may be applied not only for tissue ablation, but also for local drug delivery, gene therapy, and drug activation.


Subject(s)
Hyperthermia, Induced , Magnetic Resonance Imaging , Radiography, Interventional , Ultrasonic Therapy , Animals , Rabbits , Swine
15.
J Neurol Sci ; 178(1): 10-6, 2000 Sep 01.
Article in English | MEDLINE | ID: mdl-11018243

ABSTRACT

The aim of this work was to assess quantitatively and qualitatively the ability of magnetization transfer imaging to follow in vivo remyelination. Demyelination lesions were induced in rats by the injection of L-alpha-lysophosphatidylcholine stearoyl into the corpus callosum and imaging was performed in vivo on a 4.7-Tesla system at different time points. The percentage of magnetization transfer ratio (MTR) decrease was calculated for each animal. To evaluate the MTR findings for remyelination, myelin was quantitated by histological analysis of the lesion size and counting the number of remyelinating axons. An MTR decrease was observed when demyelination was present at 7 days after injection. During the remyelinating phase between day 30 and 40 after injection, contralateral values almost complete returned to normal, thus indicating remyelination. Histologically, at days 30 and 40 after injection, the lesion area was reduced in size and the axons were surrounded by a thin myelin sheath, indicating the remyelination process. Statistical analysis showed that the profile of MTR values was significantly correlated with the course of remyelination. All the MTR changes show a correlation with both myelin damage and repair. In conclusion, the study of the MTR profile in this myelin lesion model demonstrates in vivo the loss of myelin and the presence of spontaneous remyelination. This methodological approach which can also be applied to multiple sclerosis patients to show demyelination, should prove helpful to determine the degree of spontaneous and therapeutically induced remyelination in multiple sclerosis lesions, and thus to validate therapeutic treatments for myelin repair.


Subject(s)
Corpus Callosum/pathology , Magnetic Resonance Imaging , Myelin Sheath/pathology , Animals , Corpus Callosum/injuries , Corpus Callosum/metabolism , Lysophosphatidylcholines , Magnetic Resonance Imaging/methods , Male , Myelin Sheath/metabolism , Myelin Sheath/physiology , Pilot Projects , Rats , Rats, Wistar
16.
J Magn Reson Imaging ; 12(4): 525-33, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11042633

ABSTRACT

Continuous thermometry during a hyperthermic procedure may help to correct for local differences in heat conduction and energy absorption, and thus allow optimization of the thermal therapy. Noninvasive, three-dimensional mapping of temperature changes is feasible with magnetic resonance (MR) and may be based on the relaxation time T(1), the diffusion coefficient (D), or proton resonance frequency (PRF) of tissue water. The use of temperature-sensitive contrast agents and proton spectroscopic imaging can provide absolute temperature measurements. The principles and performance of these methods are reviewed in this paper. The excellent linearity and near-independence with respect to tissue type, together with good temperature sensitivity, make PRF-based temperature MRI the preferred choice for many applications at mid to high field strength (>/= 1 T). The PRF methods employ radiofrequency spoiled gradient-echo imaging methods. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 second and a spatial resolution of about 2 mm, is feasible for a single slice for immobile tissues. Corrections should be made for temperature-induced susceptibility effects in the PRF method. If spin-echo methods are preferred, for example when field homogeneity is poor due to small ferromagnetic parts in the needle, the D- and T(1)-based methods may give better results. The sensitivity of the D method is higher that that of the T(1) methods provided that motion artifacts are avoided and the trace of D is evaluated. Fat suppression is necessary for most tissues when T(1), D, or PRF methods are employed. The latter three methods require excellent registration to correct for displacements between scans.


Subject(s)
Hyperthermia, Induced , Magnetic Resonance Imaging/methods , Animals , Body Temperature , Humans , Rabbits , Swine
17.
J Magn Reson Imaging ; 12(4): 571-83, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11042639

ABSTRACT

The objective of hyperthermia treatment is to deliver a similar therapeutic thermal dose throughout the target volume within a minimum amount of time. We describe a noninvasive approach to this goal based on magnetic resonance imaging (MRI)-guided focused ultrasound (FUS) with a spherical transducer that can be moved along two directions inside the bed of a clinical MR imager and that has an adjustable focal length in the third dimension. Absorption of FUS gives rise to a highly localized thermal buildup, which then spreads by heat diffusion and blood perfusion. A uniform temperature within a large target volume can be obtained using a double spiral trajectory of the transducer focal point together with constant and maximum FUS power. Differences between the real and target temperatures during the first spiral are evaluated in real time with temperature MRI and corrected for during the second spiral trajectory employing FUS focal point velocity modulation. Once a uniform temperature distribution is reached within the entire volume, FUS heating is applied only at the region's boundaries to maintain the raised temperature levels. Heat conduction, together with the design and timing of the trajectories, therefore ensures a similar thermal dose for the entire target region. Good agreement is obtained between theory and experimental results in vitro on gel phantoms, ex vivo on meat samples, and in vivo on rabbit thigh muscle. Edema in muscle was visible 1 hour after hyperthermia as a spatially uniform rise of the signal intensity in T(2)-weighted images.


Subject(s)
Hyperthermia, Induced/methods , Magnetic Resonance Imaging/methods , Ultrasonic Therapy , Animals , Female , Muscle, Skeletal , Phantoms, Imaging , Rabbits , Temperature , Transducers , Ultrasonic Therapy/methods
18.
J Magn Reson ; 146(1): 223-7, 2000 Sep.
Article in English | MEDLINE | ID: mdl-10968976

ABSTRACT

A method for in-plane imaging of large objects as compared to the RF coil is proposed based on the use of a single specially designed surface coil, without using B(0) gradients. A constant B(1) gradient was generated along the main axis of a ladder-shaped coil, and RF-encoding along the direction of the gradient made it possible to obtain spin-density profiles. Successive acquisitions of profiles obtained by translation of the NMR coil resulted in distorted images-due to the presence of non-zero gradients perpendicular to the constant gradient-that were successfully processed using a mathematical treatment based on linear combinations of calculated altered images from single-pixel objects. Copyright 2000 Academic Press.

19.
J Neurochem ; 72(6): 2445-55, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10349854

ABSTRACT

C6 cells were used to establish a glioma-bearing rat model by stereotaxic injection in the left caudate nucleus. The tumor status was evaluated by magnetic resonance imaging and conventional histology. The glioma-bearing rats were infused for 1 h with a [1-(13)C]glucose solution. Perchloric acid extracts of the tumor and the ipsilateral and contralateral hemispheres were analyzed by 13C-NMR spectroscopy. The 13C-labeling patterns in compounds, mainly amino acids, indicated no drastic modification of carbon metabolism in both ipsilateral and contralateral hemispheres, as compared with control rats, whereas profound metabolic differences between brain tissue and tumor were observed. Glutamine C4 enrichment was lower in the glioma than in the brain [mean +/- SD values, 5.4 +/- 2.3 (n = 5) and 15.0 +/- 0.8% (n = 10), respectively] and also lower than the glutamate C4 enrichment in the glioma (mean +/- SD value, 22.6 +/- 4.2%; n = 5), indicating that tumor glutamine was neither synthesized inside the glioma nor taken up from the surrounding brain. The glutamine C4 enrichment in the serum (6.7 +/- 0.5%; n = 10) suggested that the glioma imported glutamine from the blood, a process probably connected with angiogenesis.


Subject(s)
Brain Neoplasms/metabolism , Brain/metabolism , Glioma/metabolism , Glucose/metabolism , Alanine/metabolism , Amino Acids/metabolism , Analysis of Variance , Animals , Aspartic Acid/metabolism , Body Weight , Brain/pathology , Brain Neoplasms/pathology , Carbon Isotopes , Citric Acid Cycle , Female , Functional Laterality , Glioma/pathology , Glutamic Acid/metabolism , Glutamine/metabolism , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Models, Chemical , Nerve Tissue Proteins/metabolism , Rats , Rats, Wistar , Tumor Cells, Cultured , gamma-Aminobutyric Acid/metabolism
20.
Diabetes ; 48(2): 327-33, 1999 Feb.
Article in English | MEDLINE | ID: mdl-10334309

ABSTRACT

In healthy individuals, glycogen recovery after a strong depletion is known to be rapid and insulin independent during the initial phase, and subsequently, slow and insulin dependent. Free fatty acids (FFAs) as a putative source of insulin resistance (IR) could thus impair glycogen recovery during the second period. Using in vivo 13C nuclear magnetic resonance (NMR), we studied the effect of long-chain triglyceride emulsion on gastrocnemius glycogen resynthesis during a 3-h recovery period after 90 min of moderate exercise consisting of plantar flexion on overnight-fasted healthy men (n = 8). In separate experiments, each subject was infused with 10% Ivelip (0.015 ml x kg(-1) x min(-1)) or 10% glycerol (0.13 mg x kg(-1) x min(-1)). NMR spectra were acquired before and at the end of the exercise and during the recovery period. Whole-body glucose and lipid oxidation rates (indirect calorimetry), plasma insulin, C-peptide, glucose, lactate, beta-hydroxybutyrate, triglycerides, and FFAs were determined. Glycogen consumption was 47.6 +/- 4.5% (glycerol) and 49.7 +/- 4.8% (Ivelip) of the initial glycogen. An acquired IR in the Ivelip group was significant at the onset of the recovery period by homeostasis model assessment (P = 0.002). Glycogen resynthesis in the glycerol group appeared faster during the 1st h than during the subsequent 2nd h of the postexercise period. The glycogen resynthesis level was significantly lower in the Ivelip group than in the glycerol group during the recovery period (P = 0.04 during the 1st h and P = 0.001 during the next 2 h). During the recovery, plasma lactate and whole-body oxidation rates were similar in the two groups, whereas glycemia was significantly higher in the Ivelip group. A decreased cellular uptake of glucose as a substrate for glycogenosynthesis, rather than a competition between oxidation of carbohydrate and FFA, is discussed.


Subject(s)
Exercise/physiology , Glycogen/antagonists & inhibitors , Glycogen/biosynthesis , Muscle, Skeletal/drug effects , Muscle, Skeletal/metabolism , Triglycerides/pharmacology , Adult , Carbon Isotopes , Emulsions , Fatty Acids, Nonesterified/blood , Glycerol/blood , Glycerol/pharmacology , Humans , Infusions, Intravenous , Insulin Resistance/physiology , Lipid Metabolism , Magnetic Resonance Spectroscopy , Male , Oxidation-Reduction , Reference Values , Triglycerides/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...