Sensors (Basel) ; 24(6)2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38544099

ABSTRACT

A comparison of low-cost radon monitors was conducted at the Laboratory of Natural Radiation (LNR). The monitors we evaluated were EcoQube, RadonEye, RadonEye Plus2, Spirit, ViewPlus, ViewRadon and WavePlus. An AlphaGUARD monitor calibrated at the Laboratory of Environmental Radioactivity of the University of Cantabria (LaRUC), accredited for testing and calibration according to ISO/IEC 17025, provided the reference value of radon concentration. The temporal stability of the monitors was studied, obtaining a percentage of missing records ranged from 1% to 19% of the data. The main technical characteristics studied were temporal stability, measurement ranges, accuracy, correlation and response time. The main results show that the measurement ranges align with those specified by their manufacturers, with percentage differences with respect to the reference monitor of between 5% and 16%. The diversity found for response time is remarkable, with values ranging from 1 to 15 h, with Pearson correlation factors between 0.63 and 0.90.

2.
Article in English | MEDLINE | ID: mdl-35409895

ABSTRACT

Interlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and methodologies. In the framework of the traceRadon Project, two radon flux intercomparison campaigns were carried out in October 2021 at high and at low radon source areas. Four institutions participated in the field intercomparison exercises with their own systems. Every system was based on a specific radon monitor (diffusion or pump mode) and an accumulation chamber (with manual or automatic opening). Radon fluxes were calculated by each participant using both exponential and linear fittings of the radon activity concentration measured over time within the accumulation chambers. The results of this study show mainly: (i) the exponential approach is not advisable due to the variability of the radon flux and the leakage of the systems during long-time measurements; (ii) the linear approach should be applied to minimize the measurement period in agreement with the time response and sensitivity of the monitors; (iii) radon flux measured at high radon source areas (radium content of about 800 Bq kg-1) risks being underestimated because of the influence of advective effects; (iv) radon flux measured at low radon source areas (radium content of about 30 Bq kg-1) may present large uncertainties if sensitive radon monitors with pump mode are not used.


Subject(s)
Air Pollutants, Radioactive , Radiation Monitoring , Radium , Radon , Air Pollutants, Radioactive/analysis , Exercise , Humans , Radiation Monitoring/methods , Radium/analysis , Radon/analysis
3.
Article in English | MEDLINE | ID: mdl-35329349

ABSTRACT

A study is presented on rapid episodes of air exchange in the Polychrome Room of the Altamira Cave (Cantabria, Spain) using continuous monitoring of radon and CO2 tracer gases, as well as environmental parameters such as internal and external air temperature. For this, criteria have been developed to carry out an inventory of these types of events during the 2015-2020 period. Most of the degassing-recharging events occur over several hours or days, especially during spring and autumn. This means that the room can be significantly ventilated during these short periods of time, posing an exchange of energy and matter with potential impact in the preservation of the rock art present inside. In addition, the hypothesis that temperature gradients between the internal and external atmosphere is one of the main factors that induces degassing has been tested. To this end, correlation analysis has been carried out between the different magnitudes involved in this study, such as radon and CO2 concentrations, and air temperature gradients. A total of 37 degassing-recharging events have been analyzed for the 5 year studied period. The distribution of the duration of the events have been described, as well as that of the correlations between the degassing and recharge stages of each event, showing significant values of r coefficients for the correlation with temperature gradients between the internal and external atmosphere.


Subject(s)
Air Pollutants, Radioactive , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Carbon Dioxide/analysis , Caves , Radon/analysis , Ventilation
4.
Article in English | MEDLINE | ID: mdl-34831904

ABSTRACT

An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m3, the variation was about 4% for a level of confidence of approximately 95% (k=2). For lower exposure levels, the variation increased to about 6%.


Subject(s)
Air Pollutants, Radioactive , Radiation Monitoring , Radiation Protection , Radon , Air Pollutants, Radioactive/analysis , Calibration , Humans , Radon/analysis
5.
Article in English | MEDLINE | ID: mdl-33540910

ABSTRACT

One of the requirements of EU-BSS (European Basic Safety Standards) is the design and implementation of a National Radon Action Plan in the member states. This should define, as accurately as possible, areas of risk for the presence of radon gas (222Rn) in homes and workplaces. The concept used by the Spanish Nuclear Safety Council (CSN), the body responsible for nuclear safety and radiation protection in Spain, to identify "radon priority areas" is that of radon potential. This paper establishes a different methodology from that used by the CSN, using the same study variables (indoor radon measurements, gamma radiation exposure data, and geological information) to prepare a radon potential map that improves the definition of the areas potentially exposed to radon in Spain. The main advantage of this methodology is that by using simple data processing the definition of these areas is improved. In addition, the application of this methodology can improve the delimitation of radon priority areas and can be applied within the cartographic system used by the European Commission-Joint Research Center (EC-JRC) in the representation of different environmental parameters.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radiation Protection , Radon , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Radon/analysis , Spain
6.
Article in English | MEDLINE | ID: mdl-32182944

ABSTRACT

Interlaboratory comparisons are a basic part of the regular quality controls of laboratories to warranty the adequate performance of test and measurements. The exercise presented in this article is the comparison of indoor radon gas measurements under field conditions performed with passive detectors and active monitors carried out in the Laboratory of Natural Radiation (LNR). The aim is to provide a direct comparison between different methodologies and to identify physical reasons for possible inconsistencies, particularly related to sampling and measurement techniques. The variation of radon concentration during the comparison showed a big range of values, with levels from approximately 0.5 to 30 kBq/m3. The reference values for the two exposure periods have been derived from a weighted average of participants' results applying an iterative algorithm. The indexes used to analyze the participants' results were the relative percentage difference D(%), the Zeta score ( ζ ), and the z-score ( z ). Over 80% of the results for radon in air exposure are within the interval defined by the reference value and 20% and 10% for the first and the second exposure, respectively. Most deviations were detected with the overestimating of the exposure using passive detectors due to the related degassing time of detector holder materials.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Background Radiation , Laboratories
7.
J Radiol Prot ; 40(2): 367-380, 2020 06.
Article in English | MEDLINE | ID: mdl-31978929

ABSTRACT

The atmosphere of caves is a special environment where it is necessary to take into account some particular characteristics when assessing the radon dose. The equilibrium factor (F) between radon and its progeny, and especially its unattached fraction (f p), is a key parameter in radon dose evaluation. In order to consider the specific features of the atmosphere in the Altamira Cave, the radon and particle concentrations have been measured. The mean annual radon concentration inside the cave over the period 2013-2019 is around 3500 Bq m-3 with a standard deviation of 1833 Bq m-3 and this exhibits seasonal variations. This value surpasses all international (WHO, IAEA, ICRP) upper action and reference levels (occupational and non-occupational). Dose rate levels expressed in µSv h-1 were estimated for four different equilibrium scenarios between radon and its progeny 218Po, 214Pb, 214Bi and 214Po. The most recent dose conversion factors have been used and the contribution made to the dose by the unattached fraction of radon progeny f p has been also assessed from the particle concentration. The results suggest that the mean annual dose levels show variations of up to 500% due to the range of F and the f p considered in this study. Given the high radon concentrations usually found in show caves, the best way to reduce this variability and its associated uncertainty in dose assessment is to conduct specific studies aimed at determining both F and f p.


Subject(s)
Air Pollutants, Radioactive/analysis , Caves , Radiation Monitoring/methods , Radon/analysis , Humans , Radiation Dosage , Radon Daughters/analysis , Spain
8.
J Radiol Prot ; 38(3): 1111-1127, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30095080

ABSTRACT

The purpose of this paper is to benchmark several different radon monitors, by quantifying their accuracy and response time. Radon monitors with different characteristics were tested in a purpose-built radon chamber under reference conditions. The radon concentration in the chamber was controlled and maintained at a stable radon concentration of (2648 ± 85) Bq m-3 to evaluate the accuracy and precision of these monitors. The response time of the monitors was analysed for two time intervals. To assess the response time of the monitors, radon concentration was varied from a theoretical value of 0-6441 Bq m-3 and then from 6441 to 2648 Bq m-3. The results from this study show that general purpose radon monitors are less accurate than those used by radon testing service providers and the research community. All monitors tested reported a mean radon concentration within the ±10% of the reference detector value at the radon equilibrium concentration. Different response time analysis methods were proposed and discussed, and for the particular time intervals analysed, response time was found to be slower for those radon monitors intended for general purpose applications.


Subject(s)
Air Pollution, Indoor/analysis , Radiation Monitoring/instrumentation , Radon/analysis
9.
Sci Total Environ ; 610-611: 1125-1132, 2018 Jan 01.
Article in English | MEDLINE | ID: mdl-28847132

ABSTRACT

Residential radon exposure is a serious public health concern, and as such appears in the recommendations of European Code Against Cancer. The objective of this study was to assess the association between residential radon levels and mortality due to different types of cancer, using misaligned data analysis techniques. Mortality data (observed cases) for each of the 313 Galician municipalities were drawn from the records of the National Statistics Institute for the study period (1999-2008). Expected cases were computed using Galician mortality rates for 14 types of malignant tumors as reference, with a total of 56,385 deaths due to the tumors analyzed. The effect estimates of indoor radon (3371 sampling points) were adjusted for sociodemographic variables, altitude, and arsenic topsoil levels (1069 sampling points), using spatial/geostatistical models fitted with stochastic partial differential equations and integrated nested Laplace approximations. These models are capable of processing misaligned data. The results showed a statistical association between indoor radon and lung, stomach and brain cancer in women in Galicia. Apart from lung cancer (relative risk (RR)=1.09), in which a twofold increase in radon exposure led to a 9% rise in mortality, the association was particularly relevant in stomach (RR=1.17) and brain cancer (RR=1.28). Further analytical epidemiologic studies are needed to confirm these results, and an assessment should be made of the advisability of implementing interventions targeting such exposure in higher-risk areas.


Subject(s)
Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/statistics & numerical data , Environmental Exposure/statistics & numerical data , Neoplasms, Radiation-Induced/epidemiology , Radon/analysis , Female , Housing , Humans , Risk , Spain/epidemiology
10.
Sci Total Environ ; 624: 416-423, 2018 May 15.
Article in English | MEDLINE | ID: mdl-29268214

ABSTRACT

The use of radon as an atmospheric tracer in the Altamira Cave over the past 30years has provided relevant information about gaseous exchanges between the Polychromes Room, the adjoining Chambers inside the cave, and the outside atmosphere. The relatively simple physico-chemical behaviour of radon gas provides a marked advantage over other tracer gases that are usually present in high concentrations in hypogeous environments, such as CO2. Two types of continuous radon measurement were undertaken. The first involves active detectors located in the Hall and Polychromes Room, which provide radon concentration values at 1-hour intervals. In addition, nuclear solid track etched detectors (CR-39) are used in every chamber of the cave over 14-day exposure periods, providing average radon concentrations. In this paper we show some of the specific degassing and recharge events identified by anomalous variations in the concentration of radon gas in the Polychromes Room. In addition, we update knowledge regarding the degree of connection between chambers inside the cave and with the outside atmosphere. We verify that the connection between the Polychromes Room and the rest of the cave has been drastically reduced by the installation of the second closure in 2008. Except for point exchanges with the Crossing zone generated by a negative temperature gradient in that direction, the atmosphere of the Polychromes Room remains stable, or else it exchanges matter with the outside atmosphere through the karst interface. The role of radon as a tracer is demonstrated to be valid both to reflect seasonal cycles of degassing and recharge, and to analyse shorter (daily) period fluctuations.

11.
Sci Total Environ ; 543(Pt A): 460-466, 2016 Feb 01.
Article in English | MEDLINE | ID: mdl-26599146

ABSTRACT

Radon ((222)Rn) levels in air and water have been analyzed continuously for almost a year in Las Caldas de Besaya thermal spa, north Spain. Radon is a naturally occurring noble gas from the decay of radium ((226)Ra) both constituents of radioactive uranium 238 series. It has been recognized as a lung carcinogen by the World Health Organization (WHO) and International Agency for Research on Cancer (IARC). Furthermore the Royal Decree R.D 1439/2010 of November, 2010 establishes the obligation to study occupational activities where workers and, where appropriate, members of the public are exposed to inhalation of radon in workplaces such as spas. Together with radon measures several physico-chemical parameters were obtained such as pH, redox potential, electrical conductivity and air and water temperature. The devices used for the study of the temporal evolution of radon concentration have been the RTM 2100, the Radon Scout and gamma spectrometry was complementarily used to determine the transfer factor of the silicone tubes in the experimental device. Radon concentrations obtained in water and air of the spa are high, with an average of 660 Bq/l and 2900 Bq/m(3) respectively, where water is the main source of radon in the air. Radiation dose for workers and public was estimated from these levels of radon. The data showed that the thermal processes can control the behavior of radon which can be also influenced by various physical and chemical parameters such as pH and redox potential.


Subject(s)
Air Pollutants, Radioactive/analysis , Hot Springs , Radiation Monitoring , Radon/analysis , Water Pollutants, Radioactive/analysis , Groundwater , Humans , Radium/analysis , Spain
12.
Sci Total Environ ; 407(15): 4452-60, 2009 Jul 15.
Article in English | MEDLINE | ID: mdl-19428051

ABSTRACT

Radon and radon progeny are present indoors, in houses and others dwellings, representing the most important contribution to dose from natural sources of radiation. Most studies have demonstrated an increased risk of lung cancer at high concentration of radon for both smokers and nonsmokers. The work presents a comparative analysis of the radon exposure data in the two radon-prone areas, Stei, Transylvania, (Romania), in the near of old Romanian uranium mines and in the granitic area of Torrelodones town, Sierra de Guadarrama (Spain). Measurements of indoor radon were performed in 280 dwellings (Romania) and 91 dwellings (Spain) by using nuclear track detectors, CR 39. The highest value measured in Stei area was 2650 Bq m(-3) and 366 Bq m(-3) in the Spanish region. The results are computed with the BEIR VI report estimates using the age-duration model at an exposure rate below 2650 Bq m(-3). We used the EC Radon Software to calculate the lifetime lung cancer death risks for individuals groups in function of attained age, radon exposures and tobacco consumption. A total of 233 lung cancer deaths were observed in the Stei area for a period of 13 years (1994-2006), which is 116.82% higher than expected from the national statistics. In addition, the number of deaths estimated for the year 2005 is 28, which is worth more than 2.21 times the amount expected by authorities. In comparison, for Torrelodones was rated a number of 276 deaths caused by lung cancer for a period of 13 years, which is 2.09 times higher than the number expected by authorities. For the year 2005 in the Spanish region were reported 32 deaths caused by pulmonary cancer, the number of deaths exceeding seen again with a factor of 2.10 statistical expectations. This represents a significantly evidence that elevated risk can strongly be associated with cumulated radon exposure.


Subject(s)
Environmental Exposure/analysis , Lung Neoplasms/mortality , Radon/analysis , Adult , Age Factors , Female , Humans , Lung Neoplasms/epidemiology , Male , Middle Aged , Risk Assessment , Romania , Smoking/epidemiology , Software , Spain
13.
J Hazard Mater ; 145(3): 368-71, 2007 Jul 16.
Article in English | MEDLINE | ID: mdl-17184916

ABSTRACT

High concentrations of radon exist in several workplaces like tourist caves mainly because of the low ventilation rates existing at these enclosures. In this sense, in its 1990 publication, the ICRP recommended that high exposures of radon in workplaces should be considered as occupational exposure. In developed caves in which guides provide tours for the general public great care is needed for taking remedial actions concerning radon, because in some circumstances forced ventilation may alter the humidity inside the cave affecting some of the formations or paintings that attract tourists. Tourist guides can work about 1900 h per year, so the only option to protect them and other cave workers from radon exposure is to apply an appropriate system of radiation protection mainly based on limitation of exposure by restricting the amount of time spent in the cave. Because of the typical environmental conditions inside the caves, the application of these protecting actions requires to know some indoor air characteristics like particle concentration, as well as radon progeny behaviour in order to get more realistic effective dose values In this work the results of the first two set of radon measurements program carried out in 10 caves located in the region of Cantabria (Spain) are presented.


Subject(s)
Air Pollutants, Occupational/analysis , Air Pollutants, Radioactive/analysis , Environmental Exposure/analysis , Leisure Activities , Occupational Exposure/analysis , Radon/analysis , Humans , Spain
SELECTION OF CITATIONS