1.
Article in English | MEDLINE | ID: mdl-35055485

ABSTRACT

Doses from the exposure to outdoor radon are typically an order of magnitude smaller than those from indoor radon, causing a greater interest on investigation of the latter for radiation protection issues. As a consequence, assessment of radon priority areas (RPA) is mainly based on indoor radon measurements. Outdoor radon measurements might be needed to guarantee a complete estimation of radiological risk and may help to improve the estimation of RPA. Therefore, authors have analysed the available literature on outdoor radon to give an overview of outdoor radon surveys and potential correlation with indoor radon and estimation of RPA. The review has shown that outdoor radon surveys were performed at much smaller scale compared to indoor radon. Only a few outdoor radon maps were produced, with a much smaller density, covering a larger area, and therefore putting doubt on the representativeness of this data. Due to a large variety of techniques used for outdoor radon measurements and requirement to have detectors with a high sensitivity and resistance to harsh environmental conditions, a standardised measurement protocol should be derived. This is no simple endeavour since there are more applications in different scientific disciplines for outdoor radon measurements compared to indoor radon.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Housing , Radon/analysis
2.
Article in English | MEDLINE | ID: mdl-31443348

ABSTRACT

The application of the compact disk (CD) method for radon measurements at mines, caves and other workplaces needs testing under highly variable exposure conditions. We present the results from a blind comparison of CDs exposed in the Laboratory of Natural Radiation (Saelices el Chico, Spain). During the exposure the temperature varied from 6.5 to 24.9 °C (average 12.6 °C) and the 222Rn activity concentrations varied from <10 Bq m-3 to 147 kBq m-3. Good correspondence was observed between the integrated 222Rn activity concentration determined by the reference instruments in the laboratory (122,500 ± 6100 kBq h m-3) and that assessed by analysis of the CDs at a depth 80 µm beneath the front surface (118,000 ± 12,000 kBq h m-3) and at a depth of 120 µm (106,000 ± 12,000 kBq h m-3). The theoretical modeling of the CD response under variable temperature and radon concentration suggested that the small bias is probably due to the time variation of the calibration factor because of the time variations of the temperature.


Subject(s)
Air Pollutants, Radioactive/analysis , Compact Disks/statistics & numerical data , Radiation Monitoring/methods , Radon/analysis , Calibration , Radiation Monitoring/instrumentation , Spain , Temperature
3.
J Environ Radioact ; 102(4): 378-85, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21382656

ABSTRACT

The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m(-3). Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure.


Subject(s)
Air Pollution, Indoor/prevention & control , Air Pollution, Radioactive/prevention & control , Housing , Radon/analysis , Ventilation/methods , Architecture , Pressure , Radiation Monitoring/statistics & numerical data , Spain