Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Diagnostics (Basel) ; 14(3)2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38337767

ABSTRACT

AIM: The aim of this retrospective study is to explore the introduction of edible spread cream and small candies as tools to improve motivation and compliance in young children undergoing myofunctional therapy, with the purpose of optimizing oral functions, including swallowing. METHODS: Six patients, one female and five males, between the ages of 7 and 14 years, presenting with atypical swallowing, were evaluated and treated at the clinic of the University of L'Aquila. The patients included in the study were randomly divided into two groups and were treated with two different treatment protocols: Group A: traditional myofunctional therapy and traditional tools; Group B: same exercises as group A, but with edible tools (spreadable cream and small candies). RESULTS: As expected, the two patients who used edible tools demonstrated increased motivation and collaboration during myofunctional therapy. CONCLUSIONS: Patient compliance, especially in very young patients, limits the effectiveness of myofunctional therapy; therefore, creative solutions are needed to achieve greater cooperation, and edible tools can play a significant part in retraining correct swallowing. Although the sample of this pilot study is small, the results suggest that using actual edible tools in myofunctional therapy could increase compliance and provide better results in myofunctional therapy.

2.
J Pers Med ; 13(10)2023 Oct 14.
Article in English | MEDLINE | ID: mdl-37888106

ABSTRACT

BACKGROUND: Intraoral orthodontic elastics (IOE), typically referred to as rubber bands, are important tools for correcting malocclusion, and they are classified into latex and synthetic (elastomeric-based) elastics. They have different strengths and sizes, depending on their intended use, that provide clinicians with the ability to correct both anteroposterior and vertical discrepancies. Clinical use, together with saliva, alters the physical characteristics of both latex and synthetic elastics, causing declines in strength over time. AIM: The aim of the study was to assess, through a systematic review of in vitro studies, the properties of intraoral elastics. The primary goal was to evaluate how IOEs behave in terms of tension strength and duration. The secondary goal was to investigate the force loss during the first hours of wear. The tertiary goal was to assess how these forces decayed. MATERIALS AND METHODS: The following electronic databases were searched from December 2020 to April 2021: Medline Full Text, PubMed, Cochrane Clinical Trials Register, Science Direct, and Literature Review. Out of 8505 initial articles, 10 were selected for the systematic review. RESULTS: The force-degradation property was found in all types of IOEs. The loss of strength was directly proportional to time, with the highest value during the first 3 h after extension, regardless of the elastic band size and manufacturer. The forces generated by the latex bands were higher than in those of the elastomeric-based elastics, but they did not consistently correspond to the loads specified by the manufacturers. The retention forces in the latex IOEs were significantly higher than those in the nonlatex bands, suggesting that elastomeric-based bands need to be changed more frequently and at regular intervals throughout a 24 h period. CONCLUSION: This systematic review indicates that intraoral orthodontic elastics have the greatest loss of force during the first 3 h, that latex rubber bands have the highest strength during the first hour, that the forces generated are not always consistent with the manufacturer's specifications, and that nonlatex (elastomeric-based) IOEs need to be changed frequently and regularly during a 24-h cycle.

3.
Digit Health ; 9: 20552076231204747, 2023.
Article in English | MEDLINE | ID: mdl-37846400

ABSTRACT

Introduction: Teledentistry is a specialized area within telemedicine employs digital technology and telecommunications to remotely manage dental patients, offering care, advice, education, and treatment. The significance of teledentistry escalated during the COVID-19 pandemic. Objective: This study presents a bibliometric analysis of teledentistry, based on a retrospective search of the Scopus database. Materials and methods: The research utilized Bibliometrix and VOSviewer software. Results: Publications on teledentistry have shown a recent surge, particularly since 2020, attributed to the pandemic. Out of 369 articles, just 28 (7.5%) were single-authored, while most involved collaborative efforts. These articles were dispersed across 160 journals, with the Journal Of Telemedicine And Telecare, International Journal Of Environmental Research And Public Health, and Telemedicine And E-Health each publishing over 15 articles. Remarkably, 66% of the journals featured open-access content. The University of Western Australia emerged as the most prolific institution, with 12 publications, while the United States, Chile, and Brazil led in the number of published documents. Conclusions: The growing interest in teledentistry, mainly fueled by the pandemic, has promising implications for dental practice. Despite the existing limitations, it holds potential. This bibliometric analysis provides a comprehensive overview of the field and offers valuable quantitative insights for shaping future research and funding strategies, especially concerning protocol development and digital risk assessment.

4.
Children (Basel) ; 10(7)2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37508716

ABSTRACT

BACKGROUND: The aim of the present study was to compare the changes observed in children after the early treatment of mild class III malocclusion using bimaxillary removable plates supported by class III elastics and elastodontic devices. METHODS: Twenty children (mean age 7.6 ± 1.1 years) with signs of class III malocclusion were treated using by-maxillary plates (PG group) with class III elastics (10 subjects = mean age 7.9 ± 1.3 years) or using class III elastodontic devices (EG group) (10 subjects = mean age 7.4 ± 0.8 years). Digital models and lateral cephalograms were obtained before treatment (T0) and at the end of treatment (T1). The digital models were analyzed to assess occlusal changes and maxillary morphology using the surface-to-surface matching technique. Changes in cephalometric parameters were also analyzed. The data outcomes were statistically analyzed using the paired Student's t test for inter-timing assessments and the independent Student's t test for inter-group assessments. RESULTS: Both groups showed correction of class III malocclusions, with a significant increase in the ANB angle and the overjet (p < 0.05). Subjects in the PG group exhibited a greater reduction in the inter-incisal angle compared to the EG group (p < 0.05). The children in the EG group had a significantly lower percentage of palatal morphology matching between T0 and T1 compared to the PG group (p < 0.05), suggesting greater morphological changes in the palate. CONCLUSIONS: Elastodontic appliances (EAs) and bi-maxillary plates successfully correct class III malocclusions in children. However, elastodontic devices significantly improved the morphology of the palate, both in the transverse and anteroposterior directions.

5.
Clin Oral Investig ; 27(7): 3363-3378, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37148371

ABSTRACT

OBJECTIVES: To describe the current state of the art regarding technological advances in full-automatic tooth segmentation approaches from 3D cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: In March 2023, a search strategy without a timeline setting was carried out through a combination of MeSH terms and free text words pooled through Boolean operators ('AND', 'OR') on the following databases: PubMed, Scopus, Web of Science and IEEE Explore. Randomized and non-randomized controlled trials, cohort, case-control, cross-sectional and retrospective studies in the English language only were included. RESULTS: The search strategy identified 541 articles, of which 23 have been selected. The most employed segmentation methods were based on deep learning approaches. One article exposed an automatic approach for tooth segmentation based on a watershed algorithm and another article used an improved level set method. Four studies presented classical machine learning and thresholding approaches. The most employed metric for evaluating segmentation performance was the Dice similarity index which ranged from 90 ± 3% to 97.9 ± 1.5%. CONCLUSIONS: Thresholding appeared not reliable for tooth segmentation from CBCT images, whereas convolutional neural networks (CNNs) have been demonstrated as the most promising approach. CNNs could help overcome tooth segmentation's main limitations from CBCT images related to root anatomy, heavy scattering, immature teeth, metal artifacts and time consumption. New studies with uniform protocols and evaluation metrics with random sampling and blinding for data analysis are encouraged to objectively compare the different deep learning architectures' reliability. CLINICAL RELEVANCE: Automatic tooth segmentation's best performance has been obtained through CNNs for the different ambits of digital dentistry.


Subject(s)
Spiral Cone-Beam Computed Tomography , Tooth , Humans , Reproducibility of Results , Retrospective Studies , Cross-Sectional Studies , Tooth/diagnostic imaging , Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods
6.
J Oral Biol Craniofac Res ; 13(2): 337-346, 2023.
Article in English | MEDLINE | ID: mdl-36937559

ABSTRACT

The aim of this systematic review is to analyze the properties of the different types of orthodontic retainers, identify their differences and define which type of device is most effective and less harmful to periodontal health. Methods: A literature search was carried out by a reviewer by consulting PubMed, Lilacs, Embase, Medline full text, Scopus, Web of Science, Cochrane library, and Science Direct electronic databases for biomedical and health literature as well as the grey literature and setting up the search from December 2010 without any restriction about articles languages. Results: The results showed that patients who wear retainers for a long period have significant differences in clinical parameters compared to patients without retainers. The type of retainer chosen also significantly influences the overall periodontal health of patients. Fixed retainers, both glass-fibre reinforced and steel wire retainers, proved to be the retainer type with the highest plaque and calculus accumulation values compared to removable retainers. In addition, among fixed retainers, glass-fibre reinforced retainers proved to be those that mostly promote the plaque and calculus accumulation in the application site. Conclusion: Fixed retainers are the best devices to maintain the alignment of mandibular anterior teeth in the long term. Among these devices, stainless steel lingual retainers, plain or braided, should remain the first choice. Although they are also susceptible to periodontal complications, their effect on periodontal health can be considered statistically insignificant if compared to glass-fibre reinforced retainers which, showing worse periodontal complications, should not be used.

7.
Orthod Craniofac Res ; 26(4): 642-649, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36905088

ABSTRACT

OBJECTIVES: The study aimed to compare severe crowding treatment's skeletal and dental effects by serial extractions or maxillary expansion and serial extractions in the mixed dentition phase. SETTING AND SAMPLE POPULATION: The retrospective controlled study included lateral cephalograms of 78 subjects aged 8.5 ± 1.4 years, 52 consecutively treated because of severe crowding, and 26 untreated controls matched for baseline age and observational period. METHODS: Subjects were clustered according to the treatment modality, either serial extraction (EX) or expansion and extraction (EXP-EX) group. Sagittal and vertical skeletal as well as dental cephalometric parameters were assessed at baseline and after the eruption of all permanent posterior teeth, and group comparisons were performed. RESULTS: Both treatment modalities significantly affected the vertical skeletal parameters in terms of decreasing the mandibular and occlusal plane inclination and increasing the facial height index. A distinct treatment effect on the gonial angle was observed, with a significant decrease in its superior part observed in both extraction groups. The annualized changes in the superior part of the gonial angle significantly differ (P = .036) between the Control (-0.04 ± 0.6), EX (-0.44 ± 0.6) and EXP-EX (-0.34 ± 0.5) groups. Upper and lower incisor inclination did not change significantly in any of the groups; however, the interincisal angle at follow-up was significantly smaller in the Control compared with both treated groups. CONCLUSIONS: Serial extractions and a combination of maxillary expansion and serial extractions have similar significant skeletal effects, mainly affecting vertical cephalometric parameters if performed during the pre-pubertal growth phase.


Subject(s)
Malocclusion , Serial Extraction , Humans , Palatal Expansion Technique , Retrospective Studies , Malocclusion/therapy , Mandible , Cephalometry , Maxilla
8.
Dent J (Basel) ; 11(2)2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36826196

ABSTRACT

The aim of this study was to compare the positional information transfer accuracy of palatal temporary anchorage devices (TADs) of two different brands of transfer caps: PSM and Leone. Thirty plaster casts of maxillary dental arches were chosen for master models. A couple of Leone TADs were inserted in each master model. For each master model, two analysis models were created: using two transfer caps, Leone and PSM, the impressions were taken, the analogues were connected on the transfer caps, and the casts were poured. Using digital methods and equipment, such as a 3D scanner, a 3D analysis and a comparison of the accuracy of the two transfer caps in transferring the positional information of the TADs was then made. The data obtained were analyzed using the Mann-Whitney U-test at a significance level of α = 0.05. PSM transfer caps showed higher error frequency in almost all measurements. Only two measurements had a larger error in the analysis models made with Leone transfer caps. The Mann-Whitney U-test found a significant difference between the error levels of TADs found in the analysis models created with PSM transfer caps. Leone transfer caps showed greater reliability in TADs positional information transmission.

9.
Sci Total Environ ; 866: 161356, 2023 Mar 25.
Article in English | MEDLINE | ID: mdl-36603638

ABSTRACT

Clear orthodontic aligners have recently seen increasing popularity. The thermoplastic materials present several advantages, even if it is known that all plastic products can be subjected to environmental and mechanical degradation, leading to the release of microplastics (MPs). Their ingestion could cause oxidative stress and inflammatory lesions. This study aims to evaluate the potential detachment of MPs by clear aligners due to mechanical friction simulated with a 7-day protocol in artificial saliva. The study was performed on orthodontic clear aligners from different manufacturers: Alleo (AL); FlexiLigner (FL); F22 Aligner (F22); Invisalign® (INV); Lineo (LIN); Arc Angel (ARC), and Ortobel Aligner (OR). For each group, two aligners were immersed in artificial saliva for 7 days and stirred for 5 h/day, simulating the physiological teeth mechanical friction. After 7 days, the artificial saliva was filtered; then, filters were analyzed by Raman Microspectroscopy (RMS) and Scanning Electron Microscopy (SEM), respectively to chemically identify the polymeric matrix and to measure the number and size of the detected MPs. RMS spectra revealed that AL, FL, LIN, ARC, and OR aligners were composed by polyethylene terephthalate, while F22 and INV ones by polyurethane. SEM analysis showed that the highest number of MPs was found in ARC and the lowest in INV (p < 0.05). As regards MPs' size, no statistically significant difference was found among groups, with most MPs ranging from 5 to 20 µm. Noteworthy, a highly significant correlation (p < 0.0001) was highlighted between the distribution of MPs size and the different typologies of aligners. This in vitro study highlighted for the first time the detachment of MPs from clear aligners due to mechanical friction. This evidence may represent a great concern in the clinical practice since it could impact human general health.


Subject(s)
Orthodontic Appliances, Removable , Plastics , Humans , Saliva, Artificial , Microplastics , Spectrum Analysis
10.
Children (Basel) ; 9(9)2022 Sep 14.
Article in English | MEDLINE | ID: mdl-36138698

ABSTRACT

The aim of the study was to systematically review and compare the accuracy of smartphone scanners versus stereophotogrammetry technology for facial digitization in children. A systematic literature search strategy of articles published from 1 January 2010 to 30 August 2022 was adopted through a combination of Mesh terms and free text words pooled through boolean operators on the following databases: PubMed, Scopus, Web of Science, Cochrane Library, LILACS, and OpenGrey. Twenty-three articles met the inclusion criteria. Stationary stereophotogrammetry devices showed a mean accuracy that ranged from 0.087 to 0.860 mm, portable stereophotogrammetry scanners from 0.150 to 0.849 mm, and smartphones from 0.460 to 1.400 mm. Regarding the risk of bias assessment, fourteen papers showed an overall low risk, three articles had unclear risk and four articles had high risk. Although smartphones showed less performance on deep and irregular surfaces, all the analyzed devices were sufficiently accurate for clinical application. Internal depth-sensing cameras or external infrared structured-light depth-sensing cameras plugged into smartphones/tablets increased the accuracy. These devices are portable and inexpensive but require greater operator experience and patient compliance for the incremented time of acquisition. Stationary stereophotogrammetry is the gold standard for greater accuracy and shorter acquisition time, avoiding motion artifacts.

11.
Bioengineering (Basel) ; 9(7)2022 Jun 28.
Article in English | MEDLINE | ID: mdl-35877333

ABSTRACT

The purpose of the present study was to evaluate the mechanical resistance of elastodontic devices (ED): their maximum compression loads and plastic deformation under loading (percentage). An Instron universal machine (Model 3365, Instron, Industrial Product Group, Grove City, PA, USA) was employed with a 100 N load cell and with Bluehill software for loading analyses. Each device was submitted to a five-cycles test. The following ED were evaluated: A.M.C.O.P. (Micerium, Genova, Italy) in red color, in orange color, and in blue color; HealthyStart (Ortho-Tain, Winnetka, IL, USA), and T4K™ phase 1 (Myofunctional Research Co., Helensvale, Australia). During the five-cycles test, the Ortho-Tain device delivered the greatest compression load (7.56 N), with the lowest percentage of deformation (0.95%). For all devices, a slight plastic deformation of the material was registered, ranging from 0.95% to 1.75%. For the T4K device it was not possible to complete the five-cycles test. For all the analyzed ED, a slight plastic deformation under loading was registered, that in all cases can be considered clinically acceptable. Further studies are needed to test the appliances after clinical usage.

12.
Materials (Basel) ; 15(13)2022 Jun 30.
Article in English | MEDLINE | ID: mdl-35806740

ABSTRACT

Fluoride-based mouthwashes and gels are preventive measures in countering demineralization and caries but, modifying environmental acidity, can reduce the wet corrosion resistance of orthodontic alloys. To evaluate chemical stability, in vitro experiments were conducted on stainless steel and nickel-titanium wires, weighed before and after immersion in household fluorinated mouthwashes and gels, measuring weight variations and elution of metal ions from acid corrosion phenomena. Elution samples were analyzed by inductively coupled plasma mass spectrometry, detecting residual ion concentration, while surface changes were analyzed under scanning electron microscopy. Results showed stainless steel wires do not undergo significant erosion when exposed to most fluorinated mouthwashes but, at prolonged exposure, alloys elute gradually greater amounts of metals and Ni-Ti wires become more sensitive to some mouthwashes. Ions' elution varies considerably, especially for Ni-Ti wires, if exposed to household fluorinated gels, for which significant negative values were obtained. Changes, affecting wires' outer layer, negatively act on shiny appearance and luster, reducing corrosion resistance. Although examined orthodontic wires showed good chemical stability and low toxicity, surface corrosion from exposure to fluorinated agents was observed. Home use must be accompanied by clinician prescription and, for household dental gels, must follow manufacturers' recommendations, ensuring prophylactic action without damaging alloys surfaces.

13.
Biomed Res Int ; 2022: 6493156, 2022.
Article in English | MEDLINE | ID: mdl-35686231

ABSTRACT

Epidermolysis bullosa (EB) is a group of skin disorders with skin fragility characterized by blistering from minimal mechanical trauma with rupture at the dermoepidermal junction. There are four major classical heritable EB types, due to mutations in as many as 20 distinct genes: EB simplex (EBS), junctional EB (JEB), dystrophic EB (DEB), and Kindler EB (KEB). This study is aimed at reporting case series on patients (N = 8; males, n = 5 and females, n = 3, age range 12-68 years) affected by EB and performs a review of the literature on this topic. This group of disorders can affect oral soft and hard tissues in various ways, resulting in various effects including enamel hypoplasia, dental caries, microstomia, ankyloglossia, oral blistering, and ulcerations early-onset periodontal disease. From the sample results, it can be concluded that the clinical manifestation of EB patients is highly variable and very different in prognosis. Oral health deeply influences the quality of life of EB patients. Dental management is essential to prevent the aggravation of soft tissue damage and tooth loss and to improve the quality of life through prosthetic and restorative therapies. Dentists should consider the oral alterations of EB subtypes to perform a personalized approach to the patients' needs in a preventive and therapeutic point of view.


Subject(s)
Dental Caries , Epidermolysis Bullosa Dystrophica , Epidermolysis Bullosa, Junctional , Epidermolysis Bullosa , Adolescent , Adult , Aged , Child , Epidermolysis Bullosa/genetics , Epidermolysis Bullosa/therapy , Epidermolysis Bullosa Dystrophica/genetics , Epidermolysis Bullosa, Junctional/genetics , Female , Humans , Male , Middle Aged , Quality of Life , Young Adult
14.
Healthcare (Basel) ; 10(6)2022 Jun 14.
Article in English | MEDLINE | ID: mdl-35742159

ABSTRACT

Background. Coronavirus disease has subjected the whole of humanity to two years of social isolation and a series of restrictions. These circumstances have led to the use of information technology in an increasingly widespread manner. Even in the dental field, telematic means have been used to respond to emergencies. The aim of this systematic review of the literature is to evaluate the types of orthodontic emergency that occurred most often and how they were managed by teleorthodontics during the COVID-19 pandemic. The secondary aim is that clinicians will use teleorthodontics not only during pandemics but as an additional tool to manage orthodontics. Materials and Methods. Out of 1695 articles available on PubMed, Science Direct, Cochrane and SciELO, eight articles were selected for this systematic literature review. Google Scholar was used as a secondary source to confirm that there were no additional articles. The screened papers comprised editorials, clinical studies, cross-sectional studies and retrospective studies in Italian, English or Spanish language. Results. The articles showed that the means by which patients most often communicated with their orthodontists were voice calls and smartphone applications such as WhatsApp® Messenger. Through these media, patients communicated their orthodontic emergencies. These mainly involved fixed multibracket appliances and the most common issues were discomfort and pain, fracture or loss of the appliance, protruding distal ends of archwires, brackets, tubes and bands or retainer detachment. Through teleorthodontics, patients could solve these issues by using orthodontic relief wax, cutting the protruding distal ends of the archwire with a nail clipper or a stronger cutter and removing or replacing detached bands, brackets, tubes or metallic ligature with a clean tweezer. Conclusions. In situations where personal contact is limited, teleorthodontics represents a valuable aid for professionals and patients facing orthodontic emergencies. The hope is that it may continue to represent a valuable aid for patients with difficulties in planning an in-office visit.

15.
Life (Basel) ; 12(3)2022 Feb 23.
Article in English | MEDLINE | ID: mdl-35330082

ABSTRACT

In orthodontics, post-treatment retention phase is crucial for maintaining the obtained clinical results. In cases of crowding, a bonded fixed retainer is often chosen to maintain teeth alignment in the anterior sector of the lower dental arch. A fixed retainer can remain in the mouth for years. Therefore, it is important that it is applied with harmless materials for the level of plaque control. The present study aimed to investigate the salivary concentrations of Streptococcus mutans (S. mutans) and Lactobacilli, and the Sillness and Loe plaque index, in patients wearing metal wire versus fiberglass orthodontic retainers. Forty post-orthodontic patients were included in the sample: in 20 subjects a metal wire retainer was applied (MR), while in the others a fiberglass retainer was applied (FR). The variables were recorded at baseline (T0), after 1 month (T1), and after 2 months (T2) of follow-up. The percentage of patients with a level of S. mutans and Lactobacilli colonization > 105 increased over time in the FR group (T0 = 0%, T1 = 5%, T2 = 35%), compared with the MR group. PI increased in the FR group (T0 = 0, T1 = 14, T2 = 27), and remained almost the same in the MR group (T0 = 3, T1 = 0, T2 = 2). From the present results it appears that the metal wire retainer is better than the fiberglass retainer for the level of plaque control performed by the patients.

16.
BMC Health Serv Res ; 22(1): 248, 2022 Feb 24.
Article in English | MEDLINE | ID: mdl-35209892

ABSTRACT

OBJECTIVE: The purpose of this cross-sectional observational study was to evaluate the effects of SpO2 in a sample of dental health care providers who wear a N95 mask or Filtering Face Piece (FFP2) for four consecutive hours, measured by a pulse oximeter before donning the mask and again after four hours of work and to offer some strategies to minimize discomfort and improve communication with their patients while wearing the mask. MATERIALS AND METHODS: A 17-item questionnaire was sent via Google Drive to various practitioners in Italy and the USA. A sample of 162 questionnaires were returned from dentists, orthodontists, dental hygienists and dental assistants who committed to wearing a FFP2 for 4 consecutive hours during a work day and then measuring the oxygen saturation by way of a pulse oximeter before and after the 4 working hours. The final analysis was performer on 147 viable questionnaires returned. The sample was composed of 62 males and 85 females with an average age of 42.9 ± 12.0 years. RESULTS: For the entire sample population, the baseline saturation was 98.6 ± 1.2 and, after four hours of mask wearing, there was a significant decrease in oxygen saturation to 97.0 ± 2.9 (p < 0.01). No statistical differences in SpO2 were found across specialties or across types of procedures performed during the 4 h. Heart rates were not significantly different before and after the 4 h in all categories. The 3 most frequent reported complaints were: fatigue (64%), headache (36%) and external ear pain (31%). The most common additional personal protective equipment (PPE) was a mask shield (78%) and those who wore the mask continuously reported more communication difficulty with patients, compared with those who took the mask off more often, in fact, 64% of the subjects reported that using the mask influenced their communication with their patients. Based on the results of the questionnaire, a list of breathing and vocal folds health strategies was devised and proposed, along with strategies to augment communication with patients. CONCLUSIONS: This study highlights a significant decrease in oxygen saturation after only 4 h of work (except for smokers) while wearing a FFP2, and confirms the widespread symptoms of fatigue, headache and pain behind the ears that dental professionals experience. But it also highlighted how mask wearing impaired communication with patients and wearing additional masks and a facial shield may add to those communications difficulties. This aspect and the need for better communication can lead the operators to remove the mask to improve breathing and communication, thus putting themselves at a risk of infection. Of all the aspects explored in this study, the most interesting was indeed the impact on fatigue and communication and the strategies proposed in this article can easily be implemented to reduce headache and fatigue by improving breathing efficiency and by aiding communication while donning a mask by improving voice quality and by using augmentative communication tools.


Subject(s)
COVID-19 , N95 Respirators , Adult , Cross-Sectional Studies , Female , Health Personnel , Humans , Male , Masks , Middle Aged , Oxygen Saturation , SARS-CoV-2
17.
Int J Dent ; 2022: 1637594, 2022.
Article in English | MEDLINE | ID: mdl-35190741

ABSTRACT

OBJECTIVES: The study aims at assessing the accuracy of the process of attachment bonding in aligner treatments. The analysis leads to the error estimation in the faithful reproduction of master model attachments using two types of transfer templates and two light-curing resin-based composites usually used in orthodontics. METHODS: The authors have used two transfer templates made of two different materials. The first, named Leone-biocompatible thermoforming material hard/soft, has a lower Young's modulus and is labelled as soft, while the other, named Leone-biocompatible thermoforming material, is marked as rigid. The resin-based composites possess different mechanical and rheological properties. Specifically, Transbond™ XT Light Cure Paste Adhesive, 3M has a higher viscosity than the TetricEvoflow, Ivoclar Vivadent, a flowable nanohybrid composite. The authors attempt to estimate the performance ranking between the four possible couples obtained by combining the two light-curing resin-based composites and transfer templates. Each combination was repeated in six models and compared with twelve master models, resulting in 36 total samples. A 3-D laser scanner is used to generate a digital model of each model. The comparison between digital models is the base for a comparative assessment in terms of relative and absolute error. The relative error is estimated using scalar performance indicators ranging from 0 to 1, where 1 indicates the optimum matching. The absolute error estimated from the mean square error between the coordinates of each digital model yields the reproduction accuracy in micrometer. Furthermore, the authors attempted to assess the error distribution by evaluating the point-by-point difference between the digital models. RESULTS: This analysis aims at localizing the sources of error in the considered models. The use of Transbond™ XT Light Cure Paste Adhesive, 3M with a rigid transfer template is always associated with significant accuracy and minor dispersion. However, in a few instances, using the soft template or the flowable resin-based composite can lead to bad performances. Significance. The data processing bestowed the following performance ranking from the first with lower reproduction error to the last characterized by the worst performance: (1) attachments bonding with rigid template and Transbond™ XT Light Cure Paste Adhesive, 3M, (2) attachments bonding with soft template and Transbond™ XT Light Cure Paste Adhesive, 3M, (3) attachments bonding with rigid template and TetricEvoflow, Ivoclar Vivadent, and (4) attachments bonding with soft template and TetricEvoflow, Ivoclar Vivadent.

18.
Angle Orthod ; 92(3): 358-363, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35015071

ABSTRACT

OBJECTIVES: To compare three-dimensional facial scans obtained by stereophotogrammetry with two different applications for smartphone supporting the TrueDepth system, a structured light technology. MATERIALS AND METHODS: Facial scans of 40 different subjects were acquired with three different systems. The 3dMDtrio Stereophotogrammetry System (3dMD, Atlanta, Ga) was compared with a smartphone (iPhone Xs; Apple, Cupertino, Calif) equipped with the Bellus3D Face Application (version 1.6.11; Bellus3D Inc, Campbell, Calif) or Capture (version 1.2.5; Standard Cyborg Inc, San Francisco, Calif). Times of image acquisition and elaboration were recorded. The surface-to-surface deviation and the distance between 18 landmarks from 3dMD reference images to those acquired with Bellus3D or Capture were measured. RESULTS: Capturing and processing times with the smartphone applications were considerably longer than with the 3dMD system. The surface-to-surface deviation analysis between the Bellus3D and 3dMD showed an overlap percentage of 80.01% ± 5.92% and 56.62% ± 7.65% within the ranges of 1 mm and 0.5 mm discrepancy, respectively. Images from Capture showed an overlap percentage of 81.40% ± 9.59% and 56.45% ± 11.62% within the ranges of 1 mm and 0.5 mm, respectively. CONCLUSIONS: The face image acquisition with the 3dMD device is fast and accurate, but bulky and expensive. The new smartphone applications combined with the TrueDepth sensors show promising results. They need more accuracy from the operator and more compliance from the patient because of the increased acquisition time. Their greatest advantages are related to cost and portability.


Subject(s)
Imaging, Three-Dimensional , Smartphone , Face/diagnostic imaging , Humans , Photogrammetry , Reproducibility of Results , Technology
19.
Healthcare (Basel) ; 9(9)2021 Aug 31.
Article in English | MEDLINE | ID: mdl-34574914

ABSTRACT

The aim of this study was to analyse the structural characteristics of the temporo-mandibular joint (TMJ) and the dysfunctional consequences induced by disease in subjects with juvenile idiopathic arthritis (JIA). The study was conducted in 25 patients with JIA (median age (IQR), 13.9 (10.9-15.3)) and 26 healthy controls (median age (IQR), 14.3 (11.6-17.2)) years. All enrolled patients were subjected to anamnestic evaluation, laboratory parameters, JIA subclass, and type of therapy for the disease. A clinical-gnathological evaluation, anamnestic and dysfunctional index (Ai and Di), and magnetic resonance imaging of TMJs were performed in all patients. The test group showed a significant reduction (p < 0.001) regarding the clinical findings such as maximal mouth opening, left and rightward laterotrusion and protrusion, and a significant difference in the reported symptoms (TMJ sounds, reduced mouth opening and pain), and Ai and Di (p < 0.001) compared to healthy patients. Correlation analysis showed a significant correlation between the median duration of disease and the maximum mouth opening and between visual analogue scale (VAS) score and maximum mouth opening, leftward laterotrusion, rightward laterotrusion, and protrusion. The results obtained in this study suggest that patients with JIA presented a cohort of symptoms in TMJs in comparison with healthy controls. Moreover, a careful TMJs evaluation and an early diagnosis of TMJs dysfunction and regular follow-ups are recommended in order to prevent and reduce functional and chewing problems in patients with JIA.

20.
Healthcare (Basel) ; 9(7)2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34209816

ABSTRACT

BACKGROUND: Eagle syndrome occurs when elongated styloid process or ossification of the stylohyoid ligament interfere with the surrounding anatomical structures giving rise to various symptoms. Watt W. Eagle identified two types: stylo-hyoid classic syndrome and stylo-carotid artery syndrome. The aim of this systematic review of the literature is to evaluate correlations between Eagle syndrome and traumatic events or teeth extractions. METHODS: out of 294 articles, the final study allowed the identification of 13 studies focusing on traumatic events. Out of 342 articles, the final study allowed the analysis of two studies regarding extractive dental events. RESULTS: 13 articles showed correlations between the onset of symptoms in Eagle syndrome and traumatic events and highlighted two possibilities: traumatic event could fracture the already elongated styloid process or calcified stylohyoid ligament; trauma itself triggers the pathophysiological mechanisms that lead to lengthening of styloid process or calcification of stylohyoid ligament and therefore the typical symptoms. The only two case reports concerning Eagle syndrome symptoms after extractive dental events describe the onset of classic type. CONCLUSIONS: The analyzed articles confirm correlation between traumatic event and onset of typical symptoms of Eagle syndrome. There is not enough literature linking extractive dental events to Eagle syndrome. TRIAL REGISTRATION: CRD42020185176.

SELECTION OF CITATIONS
SEARCH DETAIL
...